Sign In | Join Free | My burrillandco.com
Home > Connectors & Terminals >

Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker

    Buy cheap Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker from wholesalers
     
    Buy cheap Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker from wholesalers
    • Buy cheap Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker from wholesalers
    • Buy cheap Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker from wholesalers
    • Buy cheap Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker from wholesalers
    • Buy cheap Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker from wholesalers

    Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker

    Ask Lasest Price
    Brand Name : AUPO
    Model Number : A2-10A-F
    Certification : UL VDE CCC
    Price : Negotiable
    Payment Terms : T/T, MoneyGram
    Supply Ability : 100KKPCS Per Month
    Delivery Time : 1-2 Weeks
    • Product Details
    • Company Profile

    Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker


    Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker


    Overview


    The thermal cutoffs (TCO) are non resetting, thermally sensitive, single pole, normally closed devices and
    are intended to be used in various appliances.A temperature sensitive thermal fuse melts and opens electrical
    contacts when temperatures exceed the rating of the thermal fuse. Thermal cutoffs are providing protection
    against potentially hazardous overheating conditions in billions of products around the world.



    Dimension



    Ratings


    Model NORated functioning temp.Fusing-off tempHolding temperatureMaximum temp .limitRated currentRated voltage

    In

    8/20us

    Imax 8/20us
    P/N(Tf)(Th)(Tm)(Ir)(Ur)(15 Times)(1 Times)
    A1-10A-F102℃98±2℃72℃203℃10A250V5KA10KA
    A2-10A-F115℃112±3℃85℃203℃10A250V5KA10KA
    A4-10A-F130℃126±2℃100℃203℃10A250V5KA10KA
    A5-10A-F135℃131±3℃106℃203℃10A250V5KA10KA
    A7-10A-F138℃135±2℃109℃203℃10A250V5KA10KA

    LEAD FORMING


    It is easy to bend the copper lead as it is flexible. But it is likely to be damaged or broken if TCO lead is
    repeatedly bent over 90°. When forming the lead, be careful not to apply the forming force direct to TCO
    body.


    * Forming Sealant Lead Wire
    Bend the lead wire at least 4 mm away from the seal. The damage of the sealant worsen the air tightness.
    Note that bending is conducted with care, since the worse air tightness impedes the normal operation of TCO.
    Holders or tools used during lead forming must not grasp the body, but lead wire. Doing so can protect from
    damage to the body of TCO.


    * Forming lead wire other than sealed lead
    Bend at least 4mm away from TCO body, since excessive force to the body causes the deformation of
    TCO case.


    PRECAUTION FOR LEAD CONNECTION


    * Be careful to be free from damage, burn, nick, crack or overheating at TCO seal or body.If there are such
    damage as above, do not use.
    * Experimental assembly trials should be made to check the damage of lead wire, seal or TCO body.
    * When connecting wire to TCO, it is recommended that splice or terminal shall be used. The material of
    splice or terminal should be corrosion resistant.
    * When securing the splice or terminal to TCO, be careful not to damage the TCO body. The material of
    splice or terminal should be low heat resistace. Be careful not to cause excessive overheating due to poor
    connection method. It should be noted that the connection wire shall be flexible standard wire. If using solid
    wire, use the bending process.



    SOLDERING OF LEAD


    The following points should be noted if soldering is used to connect TCO lead.
    * Do soldering work on lead as far away from the TCO body if possible.
    * Be careful to minimize the heat transfer to TCO body. When proper means to prevent the heat transfer is
    not provided, TCO seal or body may be damaged and broken-down.

    * Mechanical security must not depend on solder alone.
    * Electric current must not pass through inner electric contact or the case of TCO when soldering. The
    passing of excess current damages the TCO element or case.
    * To shorten the working time, employ pre-soldering process at the intended soldering area.
    * Soldering Method to prevent heat.(use heatsink)


    * Tensile strength of lead

    Pull force shall not be over 2kg and push force shall not be over 0.5 kg.


    * Strength of Case Applying the excessive force to tie the case body causes deformation and effects normal operation of TCO. Since this may cause the fuse to not properly operate, be sure to avoid the excessive tying force.


    * Functioning Temperature Test Install the TCO in a chamber and gradually increasing temperature upto 20°C lower than Tf, then if the temperature of the chamber and the testing products are made equal, the temperature is increased 1°C per minute, then the fuse will function within the specified tolerance.


    * Temperature Increase Test When normal operating voltage and current are applied to the TCO in ambient temperature (20~25) °C the temperature of the TCO will go up.But the increase of temperature shall not be more than 10°C


    * Insulation Resistance After having operated in temperature test, the insulation resistance shall be more then 0.2 ohms when tested with 500V resistance measuring machine.


    * Contact Resistance Test The resistance of the both leads of the TCO should not exceed 1.5 ohms within the 10mm length of the leads. * Dielectric Voltage Withstand Test After conducting the Insulation resistance test, the TCO shall be maintained without breakdown when AC 500V is applied between the leads of the TCO for 1 Min.


    *Aging Test After keeping the TCO at the temperature 20 ± 3 °C lower then the Tf for 48 hours,the TCO shall pass the Functioning temperature test

    Quality Original Aupo Normal Close Thermally Sensitive Fuse Thermal Cutoff Switch TF 115℃ 250V 10A A2-10A-F TCO Circuit Breaker for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Aolittel Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Thermal Cutoff Fuse products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0