Sign In | Join Free | My burrillandco.com
Home > Switching Power Supply >

Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200

    Buy cheap Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200 from wholesalers
     
    Buy cheap Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200 from wholesalers
    • Buy cheap Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200 from wholesalers
    • Buy cheap Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200 from wholesalers
    • Buy cheap Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200 from wholesalers
    • Buy cheap Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200 from wholesalers

    Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200

    Ask Lasest Price
    Brand Name : Schneider
    Model Number : 140NPR31200
    Price : negotiable
    Payment Terms : T/T, Western Union
    Supply Ability : 100
    Delivery Time : 2-3 work days
    • Product Details
    • Company Profile

    Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200

    Redundant Power Supply Module SCHNEIDER TSX QUANTUM MODICON 140NPR31200​




    General Specifications

    Item 140 NRP 312 00 140 NRP 312 01
    power consumption in backplane (5VDC)
    Typical: 760 mA
    Maximum: 1000 mA
    Typical: 760 mA
    Maximum: 1000 mA
    wavelength 1310 nm 1310 nm
    fiber 50/125 µm
    62.5/125 µm
    9/125 µm
    expansion 0-2 km 0-15 km


    Optical Transmitter Specifications

    optical power –23.5...–14 dBm with 50/125 µm fibercable
    –20...–15 dBm with 62.5/125 µm fibercable
    –15...–8 dBm with 9/125 µm fiber cable
    rise / fall time 3 nsec or better 2.5 nsec or better
    transmitter disable offpower
    –45 dBm –45 dBm


    Mechanical Specifications

    weight 1 kg (2 lb) max
    dimensions (h x d x w) 250 x 103.85 x 40.34 mm (9.84 x 4.09 x 1.59 in)
    material (enclosures and bezels) polycarbonates
    space requirements 1 rack slot


    Operating Conditions

    RFI immunity (IEC 1000-4-3) 80...1000 MHz, 10 V/m
    surge (IEC 1000-4-5) 1 kV shield to ground
    electrostatic discharge (IEC 1000-4-2) 8 kV air / 4 kV contact
    dielectric strength field to bus: 1400 Vdc
    channel to channel: 500 Vdc


    Operating Conditions

    temperature 0...60 ° C (32...140 °F)
    humidity 90...95% RH non-condensing at 6 ° C
    chemical interactions Enclosures and terminal strips are made of polycarbonates. This material can be
    damaged by strong alkalis and various hydrocarbons, esters, halogens and
    ketones in combination with heat. Common products containing these include
    detergents, PVC products, petroleum products, pesticides, disinfectants, paint
    removers, and spray paints.
    altitude 2,000 m. When the altitude exceeds this, reduce the 60 ° C maximum operating
    temperature by 6 ° C/1000 m of additional elevation.
    vibration 10...57 Hz at 0.075 mm constant displacement amplitude 57...150 Hz at 1 g
    shock +/-15 g peak, 11 ms, half-sine wave


    OTHER SUPERIOR PRODUCTS

    Yasakawa Motor, Driver SG-Mitsubishi Motor HC-,HA-
    Westinghouse Modules 1C-,5X-Emerson VE-,KJ-
    Honeywell TC-,TK-GE Modules IC -
    Fanuc motor A0-Yokogawa transmitter EJA-
    Contact person: Anna
    E-mail: wisdomlongkeji@163.com
    Cellphone: +0086-13534205279

    Similar Products

    140ERT85410 140ESI06210 140HLI34000 140MSB10100
    140MSC10100 140NOA61100 140NOE31100 140NOE35100
    140NOE51100 140NOE55100 140NOE77101 140NOE77110
    140NOL91100 140NOL91120 140NOM21100 140NOM21200
    140SHS94500 140XBE10000 140XBP00200 140XBP00300
    140XBP00400 140XBP00600 140XBP01000 140XBP01600
    140XCA10206 140XCA10215 140XCA71703 140XCA71700
    140XCA71709 140XCP20000 140XCP40100 140XCP40200
    140XCP50000 140XCP51000 140XCP60000 140XCP90000
    140XSM00200 140XSM01000 140XTS00100 140XTS00200
    140XTS00209 140XTS00212 140CFU00600 140NOM25200
    140XTS00500 140XTS01203 140XTS01206 140XTS01209
    140XTS01212 140XTS10206 140XTS10215 140XTS33200
    140ACO02000 140ACO13000 140AII33000 140AII33010
    140AIO33000 140AMM09000 140ARI03010 140ATI03000

    140AVI03000 140AVO02000 140CFA04000 140CFB03200
    140CFC03200 140CFD03200 140CFE03200 140CFG01600
    140CFH00800 140CFI00800 140CFJ00400 140CFK00400


    Warning

    UNINTENDED EQUIPMENT OPERATION Do not connect a 140 NRP 312 01 single-mode fiber converter module to a 140 NRP 312 00 multi-mode fiber converter module. Failure to follow these instructions can result in death, serious injury, or equipment damage.


    140 NRP 312 00/01 fiber converter modules are an alternative method to using a dual-ring switch
    (DRS) to provide fiber optic communications in a Quantum EIO system. You can install 140 NRP 312 00/01 modules on Quantum local and RIO drops to:
    l extend the total length of the Quantum EIO network (RIO drops in separate areas of a factory that are more than 100 m apart)
    l improve noise immunity
    l resolve possible grounding issues when using different grounding methods is required between 2 buildings You can connect a 140 NRP 312 00/01 module to any 100Mbps-based Ethernet module on a Quantum rack to extend the transmission distance. Examples:
    l You can connect a 140 NRP 312 00/01 module to a 140 CRP 312 00 RIO head module or a 140 CRA 312 0• RIO adapter module in a Quantum EIO system.
    l You can connect a 140 NRP 312 00/01 module to a 140 NOC 780 00 DIO head module to manage DIO devices. There are 2 models of fiber converter modules, each supporting one type of fiber cable:
    l 140 NRP 312 00 supports multi-mode fiber cable.
    l 140 NRP 312 01 supports single-mode fiber cable.
    For details on other fiber converter modules and how they operate within Quantum and M340 networks, refer to the 140 NRP 954 00/01C Fiber Optic Repeater Modules User Guide and the BMX NRP 0200/01 Fiber Converter Module User Guide.


    Introduction

    140 NRP 312 00/01 fiber converter modules have 2 copper ports and 2 fiber ports. The fiber ports, in both multi-mode and single-mode modules, use LC-type connectors. One fiber port is used as the transmitter signal (Tx), and the other fiber port is used as the receiver signal (Rx). There are 2 models of fiber converter modules, each supporting one type of fiber cable:  140 NRP 312 00 supports multi-mode fiber cable.  140 NRP 312 01 supports single-mode fiber cable.


    140 NRP 312 00/01 Description

    The following figure shows the 140 NRP 312 00/01 fiber converter module:


    1 model number, description code, color code

    2 LEDs

    3 removable door

    4 customer identification label (Fold label and place it inside door.)

    5 Ethernet port 1

    6 Ethernet port 2

    7 fiber port 1
    8 fiber port 2


    NOTE:There are 2 separate pairs:
    l pair 1: Ethernet port 1 + fiber port 1
    l pair 2: Ethernet port 2 + fiber port 2


    Installing Fiber Converter Modules to Extend Distance Between the Local Rack and an RIO Drop

    The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m.



    1 140 NRP 312 00/01 fiber converter module interlinked with the 140 CRP 312 00 RIO head module on the local rack
    2 RIO drop with a 140 NRP 312 00/01 fiber converter module interlinked with a 140 CRA 312 •0 RIO
    adapter for fiber cable connection
    3 RIO drop without a 140 NRP 312 00/01 fiber converter module for copper cable connection
    4 fiber cable on the main ring used for distances greater than 100 m
    5 copper cable on the main ring used for distances less than 100 m


    Installing Fiber Converter Modules to Extend Distance Between RIO Drops

    The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m.



    1 140 NRP 312 00/01 fiber converter module interlinked with the 140 CRP 312 00 RIO head module on thelocal rack
    2 RIO drop with a 140 NRP 312 00/01 fiber converter module interlinked with a 140 CRA 312 •0 RIO adapter for fiber cable connection
    3 RIO drop without a 140 NRP 312 00/01 fiber converter module for copper cable connection
    4 fiber cable on the main ring used for distances greater than 100 m
    5 copper cable on the main ring used for distances less than 100 m


    Installing Fiber Converter Modules to Extend Distance Between DIO Devices

    The following figure shows a Quantum EIO network using 140 NRP 312 00/01 fiber converter modules to extend the distance between DIO devices beyond 100 m.


    1 Quantum CPU on the primary local rack
    2 Quantum CPU on the standby local rack
    3 140 CRP 312 00 RIO head module on the primary local rack
    4 140 CRP 312 00 RIO head module on the standby local rack
    5 140 NOC 780 00 DIO head module interlinked with the 140 CRP 312 00 module (3) and the
    140 NRP 312 00/01 fiber converter module (7) on the primary local rack
    6 140 NOC 780 00 DIO head module interlinked with the 140 CRP 312 00 module (4) and
    the140 NRP 312 00/01 fiber converter module (8) on the standby local rack
    7 140 NRP 312 00/01 fiber converter module interlinked with the 140 NOC 780 00 DIO head module (5) on
    the primary local rack
    8 140 NRP 312 00/01 fiber converter module interlinked with the 140 NOC 780 00 DIO head module (6) on
    the standby local rac
    9 fiber sync-link connecting the primary and standby CPUs (1 & 2)
    10 fiber sync-link connecting the primary and standby 140 CRP 312 00 modules (3 & 4)
    11 fiber sync-link connecting the primary and standby 140 NRP 312 00/01 modules (7 & 8)
    12 fiber cable on the main ring used for distances greater than 100 m
    13 dual-ring switch (DRS) used to connect DIO devices (14) to the main ring
    14 DIO device
    15 copper cable on the main ring used for distances less than 100 m


    Installing Fiber Converter Modules in a Hot Standby System

    The following figure shows a Quantum EIO Hot Standby network using 140 NRP 312 00/01 fiber converter modules to extend the distance between the local rack and RIO drops beyond 100 m. The use of fiber converter modules are useful to help avoid noise, attenuation, and/or distant grounding when the distance between the primary and standby PLCs exceeds 100 m.



    1 Quantum CPU on the primary local rack
    2 Quantum CPU on the standby local rack
    3 140 NRP 312 0• fiber converter module interlinked with the 140 CRP 312 00 RIO head module on the
    primary local rack
    4 140 NRP 312 0• fiber converter module interlinked with the 140 CRP 312 00 RIO head module on the
    standby local rack
    5 fiber sync-link connecting the primary and standby CPUs
    6 fiber sync-link connecting the primary and standby 140 NRP 312 0• fiber converter modules
    7 fiber main ring
    8 Quantum RIO drop
    9 X80 RIO drop


    Quality Typical 760 MA Redundant Power Supply Module 5VDC Backplane 140NPR31200 for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Wisdomlong Technology CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Redundant Power Supply Module products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0