    Brand Name : DAXIAN
    Model Number : DX8377
    Certification : GB/T10295-2008、ISO/DIS8301
    Price : Negotiable
    Delivery Time : 30 days after order confirmed
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram,In cash
    Supply Ability : 30 sets per month
    • Product Details
    • Company Profile

    5% Accuracy Thermal Insulation Conductivity Testing Equipment ISO/DIS830 AC 220V 50HZ

    Construction Materials Fire Resistance Thermal Conductivity Testing Equipment


    Scope of application:

    Thermal conductivity of dry test pieces of clay and sand, the thermal resistance of the sample should be greater than 0.1m2.K / W.

    A thermal flow meter is used to detect the thermal conductivity and thermal resistance of clay, sand, etc., and the computer is used to realize automatic detection and generate an experimental report. The instrument adopts a stable hot surface temperature on the side of the sample, and the heat is transferred to the cold surface (room temperature) through the sample, and the transferred heat flow is measured to calculate the thermal conductivity and thermal resistance. Specially equipped with geotechnical sample cylinder and specific heat capacity test device, which can be used for thermal conductivity analysis and specific heat capacity determination of clay, sand and other soils.


    Standard:

    It conforms to GB / T10295-2008 "Determination of Steady State Thermal Resistance and Related Characteristics of Thermal Insulation Materials" and ISO / DIS8301 "Insulation-Determination of Steady State Thermal Resistance and Related Characteristics-Heat Flow Meter Device".


    Technical parameters:

    1. Thermal conductivity range:

    Plate-like sample 0.015-400W/mk, accuracy better than 5%; Cylindrical sample 3-400W/mk, accuracy less than 5%;

    (A round sample cylinder with rock-finish soil, Ф90mm)

    2. Hot surface temperature: room temperature -99.99 °C, the use of high digital display meter temperature measurement, 0.2 precision, resolution 0.01 °C.

    3. Cold surface temperature: room temperature, using a high digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C.

    4. Hot surface temperature control: room temperature -99.99 °C, using a high number of digital display meter temperature measurement, 0.2 accuracy, resolution 0.01 °C, flat heater, two-way SCR control.

    5. Cold forced air cooling. The cold side is water-cooled to ensure stable cold face temperature (optional for temperature users)

    6. Using computer automatic testing.

    7. Heat flow range: 0.5-2000W/m2, delivery rate of 0.25 W/m2.

    8. Using WPY heat flow meter, heat flow parameters 23.26w/m2.mV.

    9. Using plexiglass windshield, can directly observe the experimental process.

    10. Uot and cold plate heat transfer area: 150 × 150 (mm), (can be manufactured according to user requirements 300/300,600/600 and other specifications of the sample).

    11. Adjustable hot and cold plate spacing: 0-160 (mm).


    The main technical parameters:

    The test range0.1 ~ 300w/m • k
    Power supplyAC 220V; 50HZ
    Heat sourceheating copper block, using 36V safe voltage heating.
    Test materialsblock or cylindrical metal, non-metallic materials, can test powder, gelatinous and other samples;
    Measuring temperature rangeroom temperature ~ 250 °C, up to 550 °C, accuracy ± 1 °C;
    The timing partrange 0 ~ 999.9s; resolution 0.1s;
    Thermal conductivity measurement accuracybetter than 10%
    Sample sizeΦ130 × (1-100) mm


    Quality 5% Accuracy Thermal Insulation Conductivity Testing Equipment ISO/DIS830 AC 220V 50HZ for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN DAXIAN INSTRUMENT EQUIPMENT CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Construction Materials Testing Equipment products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0