Sign In | Join Free | My burrillandco.com
Home > Energy Meters >

1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing

    Buy cheap 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing from wholesalers
     
    Buy cheap 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing from wholesalers
    • Buy cheap 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing from wholesalers
    • Buy cheap 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing from wholesalers
    • Buy cheap 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing from wholesalers
    • Buy cheap 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing from wholesalers

    1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing

    Ask Lasest Price
    Brand Name : GFUVE
    Model Number : GF106T-1000A2500V
    Certification : CE, UL, ISO9001, KEMA
    Price : Negotiable
    Payment Terms : Western Union, MoneyGram, T/T, , L/C, D/A, D/P
    Supply Ability : 200Sets/Month
    Delivery Time : 1-2 Weeks
    • Product Details
    • Company Profile

    1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing

    1000A 2500V Automatic portable ct analyzer with PT testing function, ratio & phase error testing

    GF106T 1000A 2500V Automatic portable ct analyzer with PT testing function, ratio & phase error testing

    GF106T 1000A 2500V Automatic portable ct analyzer is mainly used for field testing of P class CT and PT. The test items mainly include excitation characteristic, transformation ratio, polarity, degauss, 5% and 10% error curves, secondary circuit check, withstand test of power frequency alternating current and secondary load. Adopting LCD, self-equipped mini type printer supporting field printing; supporting to use USB flash disk to dump data, with simple and convenient operation.

    The need for a comprehensive current transformer testing regime is evident when the alternative is considered: a catastrophically damaging current transformer fault. A fault leading to an open secondary could cause the primary current to overwhelm the insulation, causing the winding to short circuit. Megger’s range of current transformer test equipment allows you to construct an in depth test and maintenance programme to prevent problems before they occur.


    A routine series of diagnostics and testing for your current transformer should include CT saturation testing to identify the knee point against IEEE or IEC standards, CT ratio tests to identify that the voltage ratio is within expected parameters and current transformer resistance testing for both the transformer windings and CT insulation resistance testing.


    Saturation testing for a current transformer identifies the rated knee point against IEEE or IEC standards, the point at which the transformer is no longer able to output current in proportion to its specified ratio.


    Ratio tests under normal load are achieved by comparing voltage applied to the secondary winding against the resulting voltage produced on the primary winding. Current transformer resistance tests inject test voltage to measure the DC current and calculate the resistance with allowance for temperature.

    MAIN FUNCTIONS

    I. Current Transformer (CT)II. Voltage Transformer (PT)
    1. Magnetization curve1. Excitation characteristic test
    2. Transformation ratio test2. Transformation ratio test
    3. Polarity3. Polarity
    4. 5% and 10% error curve4. Withstand test of power frequency alternating current
    5. Current Injecting5. Degauss
    6. Degauss6. Calculation of knee point value
    7. Withstand test of power frequency alternating current7. Actual secondary load test 
    8. Automatic calculation of excitation knee
    point value
    8. Resistance test
    9. Actual secondary load test 
    10. Resistance test 

    PARAMETERS


    Electrical parameters
    Accuracy0.2%, 0.5%
    Power supplyAC 220V±10% or AC 110V±10%, 50/60Hz
    Excitation voltage output0-2500Vrms,
    Excitation current output0-5Arms (20A peak-value)
    Large current output0-1000A
    Electrical parameters - continued
    Accuracy≤0.5% (0.2%RD+0.3%RG)
    Secondary winding DC resistance measurementRange0.1-300Ω
    Accuracy≤0.5% (0.2%RD+0.3%RG)
    Secondary actual load measurementRange5VA-1000VA
    Accuracy≤0.5% (0.2%RD+0.3%RG)±0.1VA
    CT/PT phase error measurementAccuracy±4min
    Resolution0.01min
    CT ratio error measurementRange≤25000A/5A(5000A/1A)
    Accuracy≤0.5%
    PT ratio error measurementRange1-500KV
    Accuracy≤0.5%
    Standards 
    Reference standardsGB1207-2006, GB1208-2006, GB16847-1997
    IEC60044-1, IEC60044-6, IEC61869-2-2012
    Safety standardsGB 4793.1-2007
    EMCEMC standard 89/336/EEC
    FCC Subpart B of Part 15 Class A
    IEC 1000-4-2 /3 /4 /6
    Mechanical parameters 
    Overall dimension (L x W x H) (mm)400 x 250 x 250
    Weight (kg)≤22
    Environmental conditions 
    Relative humidity90RH%
    Operating temperature-10°C to +40°C
    Altitude≤1000m

    Quality 1000A 2500V Automatic Portable CT PT Analyzer For Ratio & Phase Error Testing for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more CT PT Analyzer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0