Sign In | Join Free | My burrillandco.com
Home > Water Treatment >

Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment

    Buy cheap Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment from wholesalers
     
    Buy cheap Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment from wholesalers
    • Buy cheap Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment from wholesalers
    • Buy cheap Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment from wholesalers

    Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment

    Ask Lasest Price
    Brand Name : Iflow
    Model Number : TUF2000B
    Certification : ISO9001, CE
    Price : negotiable
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 5000 pieces per month
    Delivery Time : 1-2 weeks
    • Product Details
    • Company Profile

    Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment

    Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment


    Principle of operation

    This doppler inline ultrasonic flow meter, employs the frequency shift, that's the Doppler Effect, of an ultrasonic signal when it is reflected by suspended particles or gas bubbles (can be discontinusely) in motion. A metering technology uses the physical phenomenon of a sound wave which changes frequency when it is reflected by the moving discontinuities in a flowing liquid. The ultrasonic sound is transmitted into a pipe with flowing liquids, and the discontinuities reflect the ultrasonic wave with a slightly different frequency that is directly proportional to the rate of flow of the liquid (Figure 1). Current technology requires that the liquid contain at least 100 PPM of 100 micron or larger suspended particles or bubbles.


    Data sheet

    ItemsPerformance & Parameter
    ConvertorPrincipleTransit-time ultrasonic flow meter
    Accuracy+ 1%
    Operation4 keyboards operation
    Output signal1 channel 4-20mA, resistance 0-1K , accuracy 0.1%
    1 way OCT pulse (Pulse width: 6-1000ms, default: 200ms)
    1 channel relay output
    Input signal3 way 4-20mA, accuracy: 0.1%, (temp., pressure, level)
    Temperature transducer Pt100, heat / energy measurement
    CommunicationGalvanic isolation RS485, software upgrade by PC, MODBUS
    Signal cableTwisted-pair cable, 50m; RS485, transmission distance 1000m or above.
    Connect portPipe materialSteel, stainless, cast iron, copper, cement, PVC, aluminum, etc
    Pipe Dia15 - 6000 mm
    Straight pipeUpstream: 10xDia, or downstream: 5xDia, and 30xDia from pump
    MeteringLiquid type

    Single sonic wave transmittable liquid, such as municipal water, cooling

    water,

    seawater water, waste water, pure water, Sewage with particle content, such

    as oil, crude oil, lubrication oil, diesel oil, fuel oilChemicals, petrochemicals,

    heating, ventilation ,air conditioner, power plants,

    Temperature-30-160℃
    TurbidityUp to 10000 ppm and less bubble
    Flow velocity0-7 m/s
    Work environmentTemperatureConvertor: -20-60 ℃, Transducer: -30-160℃
    HumidityConvertor: 85%RH, Transducer: submersible up to depth 2m
    Power supplyDC8-36V or AC10-30V / 1.5W
    DimensionConvertor: 95*95*35mm

    Features:

    • Non-Intrusive, transducer for Most Pipes from DN32 to DN6000mm
    • Inline pipe type , insertion type or clamp on probe transducer for options
    • Wide Measuring Range of 0.05 to 9 mps
    • ±2% of Calibrated Span Accuracy
    • Configuration and Total Stored in SD
    • Protection IP65 for housing, IP68 for transducer

    Metering Diagram

    Flow measurement Heat measurement

    Doppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water TreatmentDoppler In Line Pipe Type Ultrasonic Flow Meters For Waste Water Treatment

    Reference chart

    TypeModelPipe dia (mm)TemperatureDimension (mm)
    Clamp onTS-2DN15-100-30-90℃45x25x32
    TM-1DN50-700-30-90℃64x39x44
    TL-1DN300-6000-30-90℃97x54x53
    Clamp on (high temperature)TS-2-HTDN15-100-30-90℃45x25x32
    TM-1-HTDN50-700-30-90℃64x39x44
    TL-1-HTDN300-6000-30-90℃97x54x53
    Insertion typeTC-1DN80-6000-30-90℃190x80x55
    TC-2(lengthen)DN80-6000-30-90℃335x80x55
    Pipe typeG3 (π type)DN15-25-30-160℃
    G2DN32/DN40-30-160℃
    G3DN50-6000-30-160℃

    Optional temperature transducer

    SpecificationModelDiaTemp.Water cutAccuracy
    Clamp-on temp. transducer Pt100CT-1>DN50-40-160℃No100+ 0.8℃
    Insertion temp. Transducer Pt100TCT-1Yes
    Insertion temp. Pt100 with pressurePCT-1No
    Insertion temp.Pt100 for small pipe DSCT-1<DN50Yes

    Industries

    • Chemicals
    • Petrochemicals
    • Oil & Gas
    • Heating, Ventilation & Air Conditioning (HVAC)
    • Power Plants
    • Water treatment

    Applications

    • Metering of cooling water
    • Demineralisedwater
    • Control of batching and blending operations
    • Mass flow measurement
    • Allocation measurement
    • District heating
    • Irrigation
    • Energy measurement

    Model Selection

    IModel
    YFElectromagnetic flowmeter
    TFTurbine
    VFVotex
    LXVane wheel
    TUltrasonic
    E/F display modeE: compact/local display, F: remote display
    Pipe DiaType (mm)
    xxxx

    10, 15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200, 250, 300,

    400, 500, 600, 800, 1000

    CodeAccuracy
    1+ 0.5% FS
    2+ 1.0% FS
    3+ 0.2% FS
    CodeType
    NConverter: 12 / 24 VDC, pulse output
    ATransmitter: 24VDC, 4-20mA outpt
    BIntelligent, Lion battery, no local display
    GSmart, local display, 4-20mA output
    C1Smart, local display, RS485
    C2Smart, local display, HART
    CodeType
    SCarbon steel housing
    LStainless steel housing
    GHigh pressure housing
    HL316L electrode
    HTiTitanium electrode
    HTaTantlum electrode
    HCHastelloy-C electrode
    L1Liquid media
    L2Gas media
    PPressure compensation
    TTemperature compensation
    PTPressure&Temp. Compensation
    FPTFE liner
    XRubber liner

    Sample: IYF-E-0100-1-C1-S-HL-L1-F,

    Magmeter, local display, Dia: 100mm, + 0.5%FS, carbon steel housing, smart, 4-20mA outpt,

    RS485, 316L electrode, liquid media meter, PTFE liner


    Competitive Advantage:

    • Compliance to international standards: ISO9001-2008 / GB/T19001 / MC00000-044/507
    • CE approval
    • Strict process control
    • Advanced calibration equipment
    • Engineer team
    Quality Transit Time Ultrasonic Flow Meter DN50 - 700 For Waste Water Treatment for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shanghai I Fluid Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Ultrasonic Flow Meter products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0