Sign In | Join Free | My burrillandco.com
Home > Telephones & Accessories >

Class 5 Copper Conductors XLPE Insulated Power Cable for Industrial Plants IEC 60502-1 Standard

    Buy cheap Class 5 Copper Conductors XLPE Insulated Power Cable for Industrial Plants IEC 60502-1 Standard from wholesalers
     
    Buy cheap Class 5 Copper Conductors XLPE Insulated Power Cable for Industrial Plants IEC 60502-1 Standard from wholesalers
    • Buy cheap Class 5 Copper Conductors XLPE Insulated Power Cable for Industrial Plants IEC 60502-1 Standard from wholesalers
    • Buy cheap Class 5 Copper Conductors XLPE Insulated Power Cable for Industrial Plants IEC 60502-1 Standard from wholesalers

    Class 5 Copper Conductors XLPE Insulated Power Cable for Industrial Plants IEC 60502-1 Standard

    Ask Lasest Price
    Brand Name : Shenzhen CTT cable
    Model Number : YJV
    Certification : CE, CB
    Price : On Request
    Payment Terms : L/C, T/T
    Delivery Time : 15 working days after payments
    • Product Details
    • Company Profile

    Class 5 Copper Conductors XLPE Insulated Power Cable for Industrial Plants IEC 60502-1 Standard

    IEC 60502-1 Cables

    600/1000V, XLPE Insulated Cables according to IEC 60502-1


    Applications


    These cables are used for electricity supply in low voltage installation system, They are suitable for installation in indoors and outdoors, in cable ducts, under ground, in power and switching stations, local energy distributions, industrial plants, where there is no risk of mechanical damage.


    Construction

    1. Conductors

    ------------------------------------------------------------------------------------------------------

    The conductors shall be either of Class 1 or Class 2 of plain or metal-coated annealed copper or of plain aluminium or aluminium alloy, or of Class 5 of plain or metal-coated copper in accordance with IEC 60228.
    2. Insulation

    ------------------------------------------------------------------------------------------------------

    XLPE material and thickness shall be as per IEC 60502 or BS 5467 rated for 90°C continuous operation.
    3. Assembly / Inner Covering

    ------------------------------------------------------------------------------------------------------

    The inner coverings may be extruded or lapped. For cables with circular cores, except cables with more than five cores, a lapped inner covering shall be permitted only if the interstices between the cores are substantially filled. A suitable binder is permitted before application of an extruded inner covering. The material is compatible with the insulating material,The materials used for inner coverings and fillers shall be suitable for the operating temperature of the cable and compatible with the insulating material.For halogen free cables, the inner covering and fillers shall also be halogen free compound.
    4. Armour

    ------------------------------------------------------------------------------------------------------

    Aluminum/galvanized steel/steel wires applied helically over the Inner Covering as per IEC 60502-1, or double aluminum/steel tapes and copper/tinned copper wire can also be manufactured upon request.
    5. Outer Sheath

    ------------------------------------------------------------------------------------------------------

    Outer sheath shall be of extruded PVC Type ST1/ST2 as per IEC 60502-1, Polyethylene type ST3/ST7, Halogen free compound ST8, Polychloroprene, chlorosulfonated polyethylene or similar polymers, type SE1 are also available on request.
    6. Fire Performance of Cable Sheaths

    ------------------------------------------------------------------------------------------------------

    Cables can be supplied with special flame retardant PVC outer sheath to comply with the flame test requirements of IEC 60332-3-22, IEC 60332-3-23 and IEC 60332-3-24, Halogen Free material comply to IEC60754-1/2 and IEC 60684-2.



    Physical and Electrical Characteristics:



    No.cores x
    cross-sec.
    Insulation
    thickness
    Sheath
    thickness
    Nominal
    value
    Outer Ø
    approx.
    weight
    approx.
    Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
    mm²mmmmmmkg / kmAAΩ/km
    4×40.71.813.028338504.61
    4×60.71.814.237649623.08
    4×100.71.816.756767841.83
    4×160.71.819.1829881091.15
    4×250.91.823.212491191420.73
    4×350.91.825.216891461700.52
    4×501.01.925.521461732010.39
    4×701.12.028.929442182450.27
    4×951.12.132.539032712940.19
    4×1201.22.335.949673153330.15
    4×1501.42.440.261333663740.12
    4×1851.62.644.476004224210.10
    4×2401.72.849.497435084890.08
    4×3001.83.056.0122715925550.06


    INSTALLATION METHOD DETAILS


    A1 – Thermally insolated wall (Single-core)A2 – Thermally insolated wall (multi-core)B1 – Apparent electroduct (Single-core)B2 – Apparent electroduct (multi-core)
    B1 – Electroduct in brickwork (Single-core)B1 – Electroduct in brickwork (multi-core)C – On the wall C – On the ceiling
    C – Non-perforated trayF – Perforated tray (Single-core)F – Perforated tray (multi-core)F –Suspended (Single-core)
    E – Suspended (multi-core)B2 – Construction spaceB2 – Construction spaceB1 – Electroduct (Single-core)
    B2 – Electroduct (Multi-core)B2 – Closed raceway embedded in floor (multi-core)B2 – Closed raceway embedded in floor (multi-core)B1 – Ventilated raceway embedded in floor
    C – Embedded in the brickworkD – Buried in additional mechanical protection

    Cable Drum Data


    CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
    Low Voltage Power Cable 0.6/1 kV 3+2 Core XLPE Insulated, PVC Sheathed, Unarmoured & Armoured to IEC 605021000700500
    1100700550
    1200700600
    1400750710
    1600900900
    180011201000
    240011501300

    RECOMMENDED ORDERING PARAMETERS

    CONTACT

    For prompt quotation / supplies please make sure your inquiries and your orders are
    securing the following data :

    1 - International or Special Standard. (Alternatively, the precise usage of the cable.)
    2 - Rated voltage.
    3 - Copper or Aluminium conductors.
    4 - Size of each conductor.
    5 - Insulation material : XLPE or others.
    6 - Number and identification of conductors.
    7 - Other requirements.
    8 - Packing.
    9 - Required delivery time.
    10 - Required validity.

    If this all seems a litle too technical for you, then why not get in touch with us.


    We look forward to assisting you in identifying the best products for your specific application and to answer any questions you might have.


    Contact person: Annie Chen

    Whatsapp: +86-13670012325
    E-mail : annie@cttcable.com
    Head office: No.130 Jingsong 3rd road, Lisonglang Community, Gongming Street, Guangming District, Shenzhen, Guangdong, China, 518000


    WARRANTY


    For a period commencing on the date shipped the Goods to Buyer and continuing for a period of 12 months thereafter.

    INSTALLATION METHOD DETAILS

    B1 – Electroduct in brickwork (Single-core)
    B1 – Electroduct in brickwork (multi-core)
    C – On the wall
    C – On the ceiling
    <img class="src=" photo="" copperconductorcable="" editor="" 20170927191416_90776.png"=""> A1 – Thermally insolated wall (Single-core)
    A2 – Thermally insolated wall (multi-core)
    B1 – Apparent electroduct (Single-core)
    B2 – Apparent electroduct (multi-core)
    C – Non-perforated tray
    F – Perforated tray (Single-core)
    F – Perforated tray (multi-core)
    F –Suspended (Single-core)
    F – Perforated tray (Single-core)
    F – Perforated tray (multi-core)
    F –Suspended (Single-core)
    E – Suspended (multi-core)
    B2 – Construction space
    B2 – Construction space
    B1 – Electroduct (Single-core)
    B2 – Electroduct (Multi-core)
    B2 – Construction space
    B2 – Closed raceway embedded in floor (multi-core)
    B1 – Ventilated raceway embedded in floor
    C – Embedded in the brickwork
    D – Buried in additional mechanical protection
    Quality Class 5 Copper Conductors XLPE Insulated Power Cable for Industrial Plants IEC 60502-1 Standard for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Chengtiantai Cable Industry Development Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more XLPE Insulated Power Cable products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0