Sign In | Join Free | My burrillandco.com
Home >

XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

    Buy cheap XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV from wholesalers
     
    Buy cheap XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV from wholesalers
    • Buy cheap XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV from wholesalers

    XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

    Ask Lasest Price
    Brand Name : Chengtiantai
    Certification : CE, CB
    Price : On Request
    Payment Terms : T/T, L/C
    Supply Ability : 20,000 KM per Month
    Delivery Time : 7/10 working days
    • Product Details
    • Company Profile

    XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV

    Medium Voltage Power Cable single core

    3.6/6 kV, 6/10 kV, 8.7/15 kV, 12/20 kV, 18/30 kV, 21/35KV, 26/35KV

    XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

    The single core cables are designed for distribution of electrical power with nominal voltage Uo/U ranging from 3.6/6KV to 26/35KV and frequency 50Hz.

    They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

    STANDER

    International:IEC60502-2

    National:GB/T 12706.1-2008

    CONSTRUCTION:

    1. CONDUCTOR

    – Bare copper class 2 to IEC 60228, round, multiwire stranded and compact

    2. CONDUCTOR SCREEN

    – Inner semi-conducting coating

    3. INSULATION

    – Core insulation of cross-linked polyethylene (XLPE)

    4. INSULATION SCREEN

    – Outer conductive layer extruded and per-manently welded with the core insulation

    Semi-conducting type
    – Over the outer semi-conducting layer, a semiconducting tape must be used.

    5. METAL SCREEN

    – copper tapes helically with a minimum thickness of 0,1 mm.

    Separator
    – Over the screen as well as under outer sheath, a separating layer must be used (e. g. taping).

    6. SHEATH

    – Outer sheath of PVC compound

    ​PHYSICAL PROPERTIES:

    Temperature range
    – during installation up to -5°C

    Operating temperature
    – max. +90°C

    Short circuit temperature
    +250°C (short circuit duration max. 5 s)

    Minimum bending radius
    – 20 x cable Ø

    Nominal /Operating /Testing Voltages

    Nominal voltage( U0/U)Operating voltage 50 HzTest voltage(kV/5 min)
    3.6/6 kV7.2 kV12.5 kV
    6/10 kV12 kV21 kV
    8.7/15 kV17.5 kV30.5KV
    12/20 kV24 kV42 kV
    18/30 kV36 kV63 kV
    21/35 kV40.5 kV73.5 kV
    26/35 kV40.5 kV91 kV

    3.6/6 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

    No. of cores and nominal cross sectionOperation
    voltage
    max.
    Nominal
    voltage
    U0/U
    Insulation
    thickness
    Sheath
    thickness
    Nominal
    value
    Outer Ø
    approx.
    weight
    approx.
    Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
    mm²kVkVmmmmmmkg / kmAAΩ/km
    1 x 357.23.6 / 62.51.618.46162051900.52
    1 x 507.23.6 / 62.51.719.97882452250.39
    1 x 707.23.6 / 62.51.7219993052750.27
    1 x 957.23.6 / 62.51.823.512763703300.19
    1 x 1207.23.6 / 62.51.824.915324303750.15
    1 x 1507.23.6 / 62.51.926.718494904250.12
    1 x 1857.23.6 / 62.51.928.321975604800.1
    1 x 2407.23.6 / 62.62.030.727636655550.08
    1 x 3007.23.6 / 62.82.133.733917656300.06
    1 x 4007.23.6 / 63.02.238.944338907250.05
    1 x 5007.23.6 / 63.22.342.2547410308250.04
    1 x 6307.23.6 / 63.22.445.6675111909400.03

    6/10 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

    No. of cores and nominal cross sectionOperation
    voltage
    max.
    Nominal
    voltage
    U0/U
    Insulation
    thickness
    Sheath
    thickness
    Nominal
    value
    Outer Ø
    approx.
    weight
    approx.
    Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
    mm²kVkVmmmmmmkg / kmAAΩ/km
    1 x 35126/ 103.41.620.66872051900.52
    1 x 50126/ 103.41.7228552452250.39
    1 x 70126/ 103.41.723.610863052750.27
    1 x 95126/ 103.41.825.513513703300.19
    1 x 120126/ 103.41.826.916224303750.15
    1 x 150126/ 103.41.928.619324904250.12
    1 x 185126/ 103.41.930.322995604800.1
    1 x 240126/ 103.42.032.728646655550.08
    1 x 300126/ 103.42.135.334597656300.06
    1 x 400126/ 103.42.238.645548907250.05
    1 x 500126/ 103.42.342.2557410308250.04
    1 x 630126/ 103.42.445.9686711909400.03

    8.7/15 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

    No. of cores and nominal cross sectionOperation
    voltage
    max.
    Nominal
    voltage
    U0/U
    Insulation
    thickness
    Sheath
    thickness
    Nominal
    value
    Outer Ø
    approx.
    weight
    approx.
    Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
    mm²kVkVmmmmmmkg / kmAAΩ/km
    1 x 3517.58.7 / 154.51.722.97792051900.52
    1 x 5017.58.7 / 154.51.724.29522452250.39
    1 x 7017.58.7 / 154.51.826.111903052750.27
    1 x 9517.58.7 / 154.51.927.714613703300.19
    1 x 12017.58.7 / 154.51.929.317384303750.15
    1 x 15017.58.7 / 154.5230.920544904250.12
    1 x 18517.58.7 / 154.5232.724275604800.1
    1 x 24017.58.7 / 154.52.135.130016655550.08
    1 x 30017.58.7 / 154.52.237.336047656300.06
    1 x 40017.58.7 / 154.52.341.947028907250.05
    1 x 50017.58.7 / 154.52.445.4575310308250.04
    1 x 63017.58.7 / 154.52.549.1703511909400.03

    12/20 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

    No. of cores and nominal cross sectionOperation
    voltage
    max.
    Nominal
    voltage
    U0/U
    Insulation
    thickness
    Sheath
    thickness
    Nominal
    value
    Outer Ø
    approx.
    weight
    approx.
    Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
    mm²kVkVmmmmmmkg / kmAAΩ/km
    1 x 352412/ 205.51.824.98602051900.52
    1 x 502412/ 205.51.826.411382452250.39
    1 x 702412/ 205.51.928.112813052750.27
    1 x 952412/ 205.51.929.915703703300.19
    1 x 1202412/ 205.5231.318394303750.15
    1 x 1502412/ 205.5233.121744904250.12
    1 x 1852412/ 205.52.134.725405604800.1
    1 x 2402412/ 205.52.237.131206655550.08
    1 x 3002412/ 205.52.239.537467656300.06
    1 x 4002412/ 205.52.344.148638907250.05
    1 x 5002412/ 205.52.447.6590510308250.04
    1 x 6302412/ 205.52.551.3722011909400.03

    18/30 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

    No. of cores and nominal crosssectionOperation
    voltage
    max.
    Nominal
    voltage
    U0/U
    Insulation
    thickness
    Sheath
    thickness
    Nominal
    value
    Outer Ø
    approx.
    weight
    approx.
    Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
    mm²kVkVmmmmmmkg / kmAAΩ/km
    1 x 503618/ 308232.613632452250.39
    1 x 703618/ 308234.316143052750.27
    1 x 953618/ 3082.136.119193703300.19
    1 x 1203618/ 3082.137.522034303750.15
    1 x 1503618/ 3082.239.325564904250.12
    1 x 1853618/ 3082.240.929345604800.1
    1 x 2403618/ 3082.343.335406655550.08
    1 x 3003618/ 3082.445.741917656300.06
    1 x 4003618/ 3082.549.152468907250.05
    1 x 5003618/ 3082.654.6656110308250.04
    1 x 6303618/ 3082.758.4790611909400.03

    21/35 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

    No. of cores and nominal crosssectionOperation
    voltage
    max.
    Nominal
    voltage
    U0/U
    Insulation
    thickness
    Sheath
    thickness
    Nominal
    value
    Outer Ø
    approx.
    weight
    approx.
    Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
    mm²kVkVmmmmmmkg / kmAAΩ/km
    1 x 5040.521/ 359.32.134.815332452250.39
    1 x 7040.521/ 359.32.136.417913052750.27
    1 x 9540.521/ 359.32.238.321153703300.19
    1 x 12040.521/ 359.32.239.724084303750.15
    1 x 15040.521/ 359.32.341.427694904250.12
    1 x 18540.521/ 359.32.343.131675604800.1
    1 x 24040.521/ 359.32.445.537906655550.08
    1 x 30040.521/ 359.32.548.144817656300.06
    1 x 40040.521/ 359.32.651.455618907250.05
    1 x 50040.521/ 359.32.757.1689410008250.04
    1 x 63040.521/ 359.32.860.8826311609400.03

    26/35 kV XLPE Insulated, Copper conductor, single core, screened, PVC sheathed

    No. of cores and nominal crosssectionOperation
    voltage
    max.
    Nominal
    voltage
    U0/U
    Insulation
    thickness
    Sheath
    thickness
    Nominal
    value
    Outer Ø
    approx.
    weight
    approx.
    Current ratings in air 30℃Current ratings buried 20℃maximum DC resistance at 20℃
    mm²kVkVmmmmmmkg / kmAAΩ/km
    1 x 5040.526/ 3510.52.237.617152452250.39
    1 x 7040.526/ 3510.52.239.219803052750.27
    1 x 9540.526/ 3510.52.341.123133703300.19
    1 x 12040.526/ 3510.52.342.526124303750.15
    1 x 15040.526/ 3510.52.444.229814904250.12
    1 x 18540.526/ 3510.52.445.933875604800.1
    1 x 24040.526/ 3510.52.548.340216655550.08
    1 x 30040.526/ 3510.52.650.947257656300.06
    1 x 40040.526/ 3510.52.754.258208907250.05
    1 x 50040.526/ 3510.52.859.7714210008250.04
    1 x 63040.526/ 3510.52.963.4852811609400.03
    *Dimensions and specifications may be changed without prior notice.

    MEDIUM VOLTAGE CABLE TESTING

    Routine tests:

    Sample tests:Type tests:

    These non-destructive tests are normally carried out on all lengths manufactured.
    - Conductor resistivity
    - Spark test on oversheath
    - Voltage tests on sheath
    - D.C. voltage test on oversheath

    These potentially destructive tests are normally carried out on every production run.
    - Examination of conductor and dimensions
    - Hot set test for XLPE insulation
    - Insulation and oversheath thickness
    - Four hour voltage test
    These destructive tests are normally carried out in addition to the above tests on commencement of a particular cable supply to validate its design.
    - Electrical type tests including bending and heat cycle
    - Non-electrical type tests including mechanical properties after ageing and tests under fire conditions.

    PACKING AND SHIPPING

    Packing: steel wooden drum, other as required ; standard delivery length is 300 m

    Packaging details :

    Delivery :

    Steel Wooden DrumsCable Drum In containershipped in 15 days after payment

    Cable Drum Data

    CABLE DRUMSD1=Flange Diameter(mm)W=Useful Width (mm)D2=Barrel Diameter(mm)
    1000700500
    1100700550
    1200700600
    1400750710
    1600900900
    180011201000
    240011501300

    Delivery Port:

    Port of ShenzhenPort of HongkongPort of Guangzhou

    Our production in numbers

    ● Cable production started 1983
    35 years of cable manufacturing experience

    ● Sales in 2016 about 500 million USD

    100,000 m2 Production area
    350 Will-trained employees
    ● Exported more than 22 countries
    2 Manufacturing plant
    1 R&D Center

    200 Sets Of Testing Equipment

    100 Testing Items
    8 workshop
    40 wire drawing machines
    10 bunching machines
    28 Extruder system
    42 stranding machines
    10 Braiding machines

    Shenzhen chengtiantai cable operates certified management systems compliant with:

    CertificatInformation
    ISO 9001:2008
    Quality management systems

    Certificat ISO 9001:2008
    - Shenzhen chengtiantai cable industry development Co.Ltd. ;
    Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
    Valid until 13 January 2019

    ISO 14001:2004
    Environmental management systems

    Certificat ISO 14001:2004

    - Shenzhen chengtiantai cable industry development Co.Ltd. ;

    Certified through Guangdong quality Testing CTC Certification Co.Ltd.;

    Valid until 13 January 2019

    OHSAS 18001:2007
    Assessment specification for occupational health & safety management systemsenvironmental management systems
    Certificat OHSAS 18001:2007
    - Shenzhen chengtiantai cable industry development Co.Ltd. ;
    Certified through Guangdong quality Testing CTC Certification Co.Ltd.;
    Valid until 13 January 2019

    Manufacturing Process Of Medium Voltage Power Cable

    1. wire drawing
    2. wire stranding
    3. Assembling
    4. Triple Extrusion Process
    5. Screening Process
    6. outer covering Process
    7. Marking
    8. cabling

    Some great shots of our manufactering plant

    Manufacturing plant
    Bird's eye on our manufacturing plant
    Wire drawing workshop
    Wire stranding
    CCV production line
    SIKORA X-ray measurement for CV
    Medium Voltage power cable shop
    Cable reel waiting to be shipped out
    Quality XLPE Insulated MV Power Cable , Single Core screened Cable 3.6/ 6 KV To 26/ 35 KV for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Chengtiantai Cable Industry Development Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Medium Voltage Power Cables products from this supplier
    Inquiry Cart 0