Sign In | Join Free | My burrillandco.com
Home > Food Sterilizer >

1200 Liter Large Steam Sterilizer With Safety Valves In Jacket and Chamber

    Buy cheap 1200 Liter Large Steam Sterilizer With Safety Valves In Jacket and Chamber from wholesalers
     
    Buy cheap 1200 Liter Large Steam Sterilizer With Safety Valves In Jacket and Chamber from wholesalers
    • Buy cheap 1200 Liter Large Steam Sterilizer With Safety Valves In Jacket and Chamber from wholesalers

    1200 Liter Large Steam Sterilizer With Safety Valves In Jacket and Chamber

    Ask Lasest Price
    Brand Name : Medpharm
    Model Number : MD-1.2Y
    Certification : CE/SGS
    Price : Negotiation
    Payment Terms : T/T in advance, LC AT SIGHT
    Supply Ability : 10 pcs per month
    Delivery Time : 35 working days after received your payment
    • Product Details
    • Company Profile

    1200 Liter Large Steam Sterilizer With Safety Valves In Jacket and Chamber

    1200 Liter Large Steam Sterilizer With Safety Valves In Jacket And Chamber

    Specification


    Model No

    MD-1.2Y

    Chamber dimensions

    mm

    680*1180*1500

    Overall dimensions

    mm

    2200*2000*1910

    Inner capacity

    L

    1200

    Door operation

    AUTO

    Horizontal single sliding

    Setting range time

    min

    0~99

    Setting range temperature

    110~135

    Controller

    Panel

    Touch screen

    System

    PLC

    Display

    5.7" Touch Screen

    Version

    Chinese/English/Spanish/Thai

    Output interface

    RS-232

    Vacuum

    Drawing

    Vacuum pump

    Printer

    Paper

    Heat sensitive type with auto rolling back

    Accessories

    Trolley

    1 set of floor-Loading carriage

    Printer paper

    2 rolls

    Manual

    1 copy of operation and maintenance manual


    Program Parameter

    Cycle name

    Further details

    Application

    Instruments/Tools

    3 times Vacuum, expose temperature 132℃, expose time 8 min, drying time 5 min.

    Solid materials to be sterilized:
    ●Packaged instruments
    ●Empty glass containers
    ●Empty metal containers
    Porous materials to be sterilized:
    ●Rubber articles

    Clothing

    3 times Vacuum, expose temperature 121℃, expose time 15 min, drying time 25 min.

    Materials to be sterilized from which air can’t be easily displaced
    ●Textile

    User Programmable

    All preset parameters can be reset; Multiple customized programs can be set and stored by user.

    Customized

    Test programs

    B-D Test

    3 times Vacuum, expose temperature 134℃, expose time 4 min, drying time 3 min.

    Test program

    Vacuum Leakage Test

    Test the chamber connecting parts’ tightness effect. It’s important to ensure the sterilization effect.

    Test program






    Description of sterilization cycle

    Pre-Vacuum Cycle - pre-conditioning of load during air removal using programmable ramped
    positive and negative pressure pulsing to remove entrapped air. Programmable ramped vacuum
    drying.


    Micro Isolator Cycle - pre-vacuum cycle using programmable, ramped, positive and negative pressure pulsing to reduce internal and external crazing of animal housing by allowing pressure stabilization to product items being processed.

    Test Cycles Leak Test - programmable vacuum leak test to verify door seal, sterilizer chambe
    r and piping integrity through monitoring of acceptable vacuum loss over selected time.


    Autoclave air removal test - pre-programmed vacuum cycle used to verify removal of residual air from
    chamber and load, and ensure steam penetration into the test load.

    Bio-Waste Cycle - designed for pre-sterilization conditioning through positive and negative pressurization to ensure air removal from mixed products in containers. Programmable ramped steam pressurization is used to maximize heat penetration of mixed laboratory biohazard waste.

    F0 Temperature Control Cycle - for the sterilization of heat sensitive materials using time-at-temperature calculations beginning at a predetermined point of the conditioning phase. This reduces the product exposure to higher temperatures normally found in standard sterilization cycles.

    Gravity Cycle - for non-air retentive products; utilizes positive steam pressure with vacuum assist air removal for conditioning of load. The end of cycle exhaust is programmable for dry and non-dry phases

    Liquid Cycles Liquid Cycle - cycle used for liquids in vented borosilicate glass or metal containers. Positive steam pressure with vacuum assisted air removal with programmable ramped heating and exhaust to ambient with optional cooling phase.

    Liquid, Air Cool Cycle - cycle used for liquids in vented borosilicate glass or metal containers
    . Positive steam pressure with vacuum assisted air removal with programmable ramped
    heating and introduction of filtered air during exhuast to speed cooling.

    Pre-Vacuum Liquid Cycle - pre-conditioning of load using programmable, ramped, positive
    and negative pressure pulsing to assist in removal of entrapped air. Chamber temperatures
    at negative pressures are controlled to prevent boiling of product. Controlled ramped exhaust
    to ambient with optional cooling phase.

    Effluent - for the processing of items in BSL3 and BSL4 laboratories. The cycle uses a heated,
    jacketed, 0.2 micron hydrophobic filter to contain biohazard contents in sterilizer chamber
    while allowing exhaust of sterile gasses.


    Advantages

    Reliability - Industrial grade valves and high temperature gaskets prevent otherwise costly
    and common service downtime. The vessel is tested and certified to exceed national pressure
    vessel standards and carries a manufacturer’s warranty.

    Safety - Operator and technician safety is ensured through temperature and pressure monitoring,
    relief valves, safety interlocks overrides.

    Serviceability - Reduce costly maintenance downtime with easy to access consumable and
    expendable components.

    Simplicity - The intuitive touch screen interface provides users with clearly identifiable selections
    to begin cycles.

    Long Life Door Gasket - Medpharm high temperature, air actuated door gaskets are seated
    into a machined groove that provides a close tolerance creating a less strenuous environment,
    extending door gasket life.



    Brochure load down from here

    Medpharm medical large steam autoclave brochure.pdf

    Quality 1200 Liter Large Steam Sterilizer With Safety Valves In Jacket and Chamber for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: ZHANGJIAGANG MEDPHARM MACHINERY LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Large Steam Sterilizer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0