Sign In | Join Free | My burrillandco.com
Home > Water Treatment >

KBSG Mine Flameproof Dry Type Transformer Mining substation

    Buy cheap KBSG Mine Flameproof Dry Type Transformer Mining substation from wholesalers
     
    Buy cheap KBSG Mine Flameproof Dry Type Transformer Mining substation from wholesalers
    • Buy cheap KBSG Mine Flameproof Dry Type Transformer Mining substation from wholesalers

    KBSG Mine Flameproof Dry Type Transformer Mining substation

    Ask Lasest Price
    Brand Name : HENTG Power
    Certification : CE
    • Product Details
    • Company Profile

    KBSG Mine Flameproof Dry Type Transformer Mining substation



    Main Specification
    Transformer Typedry type
    Rated capacityup to 8000kva
    Rated voltageup to 11kv
    Frequency50/60Hz
    Phase3 Phase
    Winding materialCopper /Aluminum
    Insulation classH(180℃), C (220℃)
    Vector groupDyn11, YNd1d1,
    Cooling

    ANAN,GNAN

    Protection EnclosureIP00 to IP54
    Explosion-proof typeExdIMb
    ZoneZone 1, Zone 2
    Tank PainingC4 and C5 on resquest
    AltitudeMax 2300m
    standardIEC, AS, EN, IEEE/ANSI, GOST


    Purpose and Conditions of Use

    This productisused inmines with methane mixed gas. coal dust and explosion risk as the powe distributiondevice ofcomprehensive mechanized mining equipment in coal mines.
    Service conditions:Theproductcan work continuously for a long time under the following service conditions and rated capacity.
    a.Altitude not exceeding 2000m;
    b.The ambient temperature is not higher than +40 ℃;
    c.The relative air humidity shall not exceed 95% (at+25℃);
    d.Thereisnostrongturbulenceandvibrationandthe inclination of the vertical plane does not exceed 15 degrees;
    e.There is no gas and steam that can corrode metal and damage insulation: f.A place without dripping water.

    Structure Overview

    Miningtameproofdrytypetranstormer KBSGis composed of box shell, box cover, iron core assembly,insulationassembly,high-voltagelead,low-voltage lead and trolley for railway track.
    The transformer box shellisanexplosion-proof structure with top open cover. Four small hoisting mixers are setonthe boxcoverfor oistingduringtheremoval of the box cover. Corrugated steel plates are used onboth sidesofthe boxshellthickstee plates are used at the bottom of the box, and connectingflanges areset on the high and lowvoltage sides of the transformer to connect high and low voltaaeswitchesourarae hoistna mixersarearranaed on the box shell for the inteara hoisting of the transformer:Bothendsofthe boxshell are welded with grounding bolts and "=" grounding marks for connecting external grounding wires.
    High andlowvoltageinterlockinglines and temperature control lines inside the transformer are respectivelyconnected with high andlowvoltage switches; PT100 platinum resistance or temperature relavisusedfortemperaturecontroWhenthetemperature in the transformer is too high. an ove temperature signal will be sent.
    Transformer coreassemblyconsists ofcore,clipsinsulating parts and so on. The iron core adopts high-qualitycold-rolled oriented silicon steel sheet multi-stage stepping full-slope three-seam aminationstructuretoreducenooadossandnooad current: Hiah temperature anti-rust and moisture-proofpaint.Theclampis made of channe steel, and the upper and lower tension adopts the pul screwstructure.andmeasuresaretakento preventthe relative dispacement of the iron core and the clamp, so as not to affect theproductquality.The core insulation parts are made of domestic high-quality insulation materials.

    Transformerinsulation assemblyincludes mainlongitudinal insulation. high and low voltage coils. coi pressingand otherstructures.Themainlongitudinal insulation is made of high-quality insulating materials High andlowvoltage coilsadopttight winding technology, which improves the mechanical strength o coils;HighandlowvoltagecoilsaremadeofC-grade insulating paper wrapped oxygen free copper conductors.The electric field aroundthe coils is uniform and the partial discharge is small. The coil shal be pressed with pressing nail and porcelain pressing block, and measures shall be taken to prevent looseness.
    The high-voltagelead isled out by cableand thelow-voltage lead is led out by cable or copper bus. The creepagedistanceand airgap aregreater than the relevant provisions in GB3836.3-2000.Under normaloperatina condtionssparksarcsanddanaeroustemperatures will not occur. and the use is safe and reliable.
    The trolleyisfixed atthebottom ofthe box with bolts and can be disassembled. The trolley gauge is900/600mm.

    Quality KBSG Mine Flameproof Dry Type Transformer Mining substation for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Hunan Hentg Power Electric Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Dry Type Transformer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0