Sign In | Join Free | My burrillandco.com
Home >

Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator

    Buy cheap Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator from wholesalers
     
    Buy cheap Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator from wholesalers
    • Buy cheap Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator from wholesalers
    • Buy cheap Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator from wholesalers
    • Buy cheap Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator from wholesalers
    • Buy cheap Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator from wholesalers

    Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator

    Ask Lasest Price
    Brand Name : HUIYUE
    Model Number : YG-RLM-15-25
    Price : 20~150
    Supply Ability : 1000
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Delivery Time : 2~3weeks
    • Product Details
    • Company Profile

    Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator

    This product adopts advanced non-magnetic technology and has the characteristics of simple structure, compact size, elegant design, and detachable body. It can be used measure the flow of heating and cooling systems in living areas. The temperature range is from 4 to 95°C. Measurement unit: kilowatt-hour optional gigacard For multi-jet heat meter, communication can be selected through M-BUS, RS-485, pulse output.


    Technical Parameters:

    MODELQn(m3/h)Length(mm)DN(mm)Sensor lengthdisplayremotetype
    RLM-15-0.60.6110151.5mkw/hM-BUS2
    RLM-15-0.60.6110151.5mGcalRS-4852
    RLM-15-1.51.5110151.5mkw/hM-BUS2
    RLM-15-1.51.5110151.5mGcalRS-4852
    RLM-20-2.52.5130201.5mkw/hM-BUS2
    RLM-20-2.52.5130201.5mGcalRS-4852
    RLM-25-2.52.5160251.5mkw/hM-BUS2
    RLM-25-2.52.5160251.5mGcalRS-4852

    Features:

    1. Flow range: 0.6~2.5m3/h.

    2. Minimum temperature difference 3°

    3. Horizontal/vertical installation

    4. Built-in removable mounting design to prevent damage during adjustment

    5. Smart multi-flow design, capable of recording flow volume

    6. Advanced non-magnetic sensor technology

    7. High precision design, meeting EN1434 and CJ128 standard 2nd class metering requirements .

    8. Battery with a lifespan of over 6 years

    9. Optional remote RS485 or M-BUS output for easy remote systems

    10. Payment settlement date be renewed, data storage for 18 months

    11. 360-degree rotatable monitoring for easy reading

    12. Tilt LCD for optimal viewing

    13. Wide measuring range (q s/q i = 100:1)

    14. Low start-up flow rate

    15. Capable measuring thermal and cold energy

    16. For cold water inlet (heat meter for return water can be provided according to user requirements)

    17. PT1000 sensor pair

    18. Ambient grade: A


    Application: Install this YG-EAS in the pipeline first before installing the heat. This will help to avoid damaging the meter and blockage of garbage the pipeline during the construction of the apartment. The heat meter can be assembled simply by opening the lid and installing the heat on the body of the YG-EAS.


    Measurement features:

    If the temperature drops, water will release heat. The heat released can be regulated by the instrument according to the temperature difference and flow. The flow signal comes from the flow sensor, and the temperature difference comes from the temperature sensor pair, and the result calculator will calculate the heat according to the flow and temperature difference

    Water pressure: ≤1.6Mpa

    Measurement accuracy: 2nd grade

    Quality Disassemblable multi-nozzle mechanical calorimeter;heat meter with removable flow sensor, M-Bus mechanical calorimeter, heat cost allocator for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Zhuhai Huiyue Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Inquiry Cart 0