| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | GENY |
| Model Number : | YC1893D |
| Certification : | ISO, CE |
| Price : | Negotiations |
| Payment Terms : | L/C,T/T,D/P |
| Supply Ability : | 100/Year |
| Delivery Time : | 30 days after order confirmed |
| Type | YC1893D-6 | YC1893D-12 | YC1893D-24 | YC1893D-48 |
| Number of meter positions | 6 | 12 | 24 | 48 |
| Accuracy | 0.05 | |||
| Power Source | YCS-103-250 | YCS-103-600 | YCS-103-1200 | YCS-103-2500 |
| Reference Standard Meter | SZ-03A-K8 | |||
| Scanning Head | YCG-2-series | |||
| Voltage | ||||
| Test voltage output(Phase-Neutral) | 3x(24V-300V)(or customized) | |||
| Power of the voltage output | Max.3x100VA | Max.3x250VA | Max.3x500VA | Max.3x1000VA |
| Resolution | Better than 0.01%of full scale value of range | |||
| Setting accuracy | Better than 0.05%at the final range value | |||
| Stability | Better than 0.005%/h(integration time 150 s) | |||
| Load regulation from 0-max.load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonics | 2nd-41st free programmable | |||
| Current | ||||
| Test current output | 3x(1mA-120A/200A) | |||
| Power of the current output | Max.3x250VA | Max.3x500VA | Max.3x1000VA | Max.3x2000VA |
| Resolution | Better than 0.01% of full scale value of range | |||
| Setting accuracy | Better than 0.05% at the final range value | |||
| Stability | Better than 0.005%/h(integration time 150 s) | |||
| Load regulation from 0-max.load | Better than 0.01% | |||
| Distortion factor | Better than 0.3% for linear resistance load | |||
| Harmonics | 2nd-41st free programmable | |||
| Phase angle | ||||
| Range | 0-360° | |||
| Resolution | 0.01° | |||
| Setting accuracy | 0.1° | |||
| Frequency | ||||
| Range | 45Hz-65Hz | |||
| Resolution | 0.01Hz | |||
| Error display | ||||
| Type of error display | Red LED | |||
| Resolution of the error displays | 8 digits | |||
Supported Meter Types: 3P4W, 3P3W
Test Modes: Active, reactive, and cross-connected reactive power
Optional ICT Module: Supports closed-link three-phase meter testing (I-P Links)
Optional Tests: Neutral current testing
Communication Options: RS232 and Ethernet for automatic calibration
Meter Compatibility: Mechanical, electromechanical, and electronic meters; supports automatic, semi-automatic, and manual operation
Durable Structure: Lightweight, strong, corrosion-resistant aluminum alloy
Efficient Mechanical Meter Testing: Auto rotor mark positioning; unified scanning head movement
Standard Functional Tests: Starting test, creeping test, and synchronous constant measurement
Protection Features: Overload, short voltage circuit, and open current circuit protection
User-Friendly Software: Windows 10/XP support; includes error, harmonic, demand, and influence tests with multi-format data export
Compliance: CE certified and meets EU health and safety standards
Our dedicated and well-trained service team ensures that every customer receives fast, reliable, and comprehensive technical support. We provide a full range of after-sales services designed to maximize the performance and longevity of our electric energy meters and meter testing instruments, including:
Preventive and corrective maintenance to ensure long-term product stability
On-site and remote technical training to help users operate and manage equipment efficiently
Customized system and solution design, tailored to different application scenarios
Regular software updates and upgrades to keep test systems accurate, compliant, and up-to-date
By combining technical expertise with customer-focused service, we ensure that clients receive continuous support throughout the entire product lifecycle, enhancing operational efficiency and overall user satisfaction.

|
| Company Info. |
| Guangzhou GENY Electric Co., Ltd |
| Verified Supplier |
| View Contact Details |
| Product List |