Sign In | Join Free | My burrillandco.com
Home > Wiring Accessories >

6500kva Cast Coil Epoxy Resin Transformer Dry Type 33000V To 900V AS60076 AS3000 Standards

    Buy cheap 6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards from wholesalers
     
    Buy cheap 6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards from wholesalers
    • Buy cheap 6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards from wholesalers
    • Buy cheap 6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards from wholesalers
    • Buy cheap 6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards from wholesalers
    • Buy cheap 6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards from wholesalers

    6500kva Cast Coil Epoxy Resin Transformer Dry Type 33000V To 900V AS60076 AS3000 Standards

    Ask Lasest Price
    Brand Name : WINLEY
    Model Number : SCB10-1250/0.48
    Certification : CE,ISO
    Price : $5000-$100000
    Payment Terms : T/T
    Supply Ability : 1000set/month
    Delivery Time : 30days
    • Product Details
    • Company Profile

    6500kva Cast Coil Epoxy Resin Transformer Dry Type 33000V To 900V AS60076 AS3000 Standards

    6500kva Cast Coil epoxy resin Transformer Dry Type 33000V To 900V AS60076



    Winley’s 6,500 kVA dry‑type cast resin transformer is engineered for reliable, low‑maintenance power distribution in commercial, industrial and utility indoor installations. Designed and manufactured to AS 60076 and AS 3000 standards, this transformer provides robust performance, excellent dielectric safety and low harmonic distortion for critical systems where fire safety, compact footprint and environmental friendliness are priorities.


    Product Photos





    Main data

    No.ParticularsUnitSpecification
    1Type~dry type, cast resin
    2Rated capacitykVA6500
    3Duty~Continuous duty
    4No. of Phase~3
    5Primary voltageV33000
    6Secondary voltageV900
    7Tapping type~off-circuit
    8Tapping range%±2*2.5%
    9Cooling method~AN/AF
    10Rated frequencyHz50
    11Vector group~Dyn11
    12Insulation class~F
    13Temperature rise100

    Technical drawings


    Built in accordance with AS/NZS 60076 and wiring per AS/NZS 3000 to ensure regulatory compliance, safety and interoperability with Australian/New Zealand power systems.


    Standard Features


    • Cooling fans for AN/AF operation to maintain thermal margins under higher load or elevated ambient temperatures.
    • Temperature monitoring: Nine PT100 sensors on the low‑voltage winding plus a resistance temperature device for thorough thermal supervision and integration with protecting/control systems.
    • Wiring and identification: All wiring and heat shrink materials installed to AS/NZS 3000. Phase identification follows the color code — Phase A (a): red, Phase B (b): white, Phase C (c): blue.


    The transformers have the following characteristics:


    • Windings have high mechanical strength and no partial discharge.
    • Epoxy resin and insulating materials used for windings are non-flammable, will not burn from an electric arc, and no toxic gases will be given off when the resin is burned.
    • Envionmental adaptability with windings that will not absorb moisture and a special anti-rust protective coating that seals the core and frame.
    • Operates under one-hundred percent relative humidity and other severe ambient conditions.
    • Ability to switch on the device without pre-drying or long periods of service interruptions.
    • Excellent short-circuit and lighting impulse strength.
    • Cooled naturally by air (AN) and forced air cooling (AF) provided as an option to improve overload capacity.
    • Smaller dimensions, less weight, and space saving.
    • Oil drainage pits and fire extinguishing devices not required for operation.

    Production process

    High-voltage winding appliesvacuumpouring of padding epoxyresin which, at highlevel,reduces partial discharge capacity andelevates the electric strength of coils. The insideand outside of the winding is buildup with glassfiber grid overlaywhich strengthens thethemechanicalrobustnessandimprovesresistance of short-circuits and ensures the coilswill never crack.

    Low-voltage winding applies the structure that windedby copper foil which solves the problem that the axle wouldpoint to the helix angle when winds and make the ampereturn of winding distribute evenly. Meanwhile, the coilsapplies axial fan which improves the heat dispersion.Between the layers of winding, it applies DMD epoxy resinpreliminary dip cloth and makes it whole solidificationfor

    Quality 6500kva Cast Coil Epoxy Resin Transformer Dry Type  33000V To 900V AS60076 AS3000 Standards for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xiamen Winley Electric Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Cast Coil Transformer products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0