Sign In | Join Free | My burrillandco.com
Home > Supplies and Equipment >

Compact Hollow Fiber Ultrafiltration Membrane 80L / M2 / H Easy Maintenance

    Buy cheap Compact Hollow Fiber Ultrafiltration Membrane 80L / M2 / H Easy Maintenance from wholesalers
     
    Buy cheap Compact Hollow Fiber Ultrafiltration Membrane 80L / M2 / H Easy Maintenance from wholesalers
    • Buy cheap Compact Hollow Fiber Ultrafiltration Membrane 80L / M2 / H Easy Maintenance from wholesalers
    • Buy cheap Compact Hollow Fiber Ultrafiltration Membrane 80L / M2 / H Easy Maintenance from wholesalers

    Compact Hollow Fiber Ultrafiltration Membrane 80L / M2 / H Easy Maintenance

    Ask Lasest Price
    Brand Name : SINOMEMB
    Model Number : SNU-HO-2-K200T
    Certification : NSF
    Price : CN¥4,855.09/pieces >=1 pieces
    Supply Ability : 1500000 Piece/Pieces per Month
    • Product Details
    • Company Profile

    Compact Hollow Fiber Ultrafiltration Membrane 80L / M2 / H Easy Maintenance

    The core SINOMEMB ® series SNU-HO-2-K200T hollow fiber UF membrane element is suitable for systems with a capacity of more than 50 m 3 /hr (220gpm) . Compact design and excellent performance help customers achieve more economical membrane system design, excellent physical and mechanical properties, better flexibility , asymmetric structure , and higher design flux make it widely used in surface water, wells Various water treatment applications such as water, seawater, industrial wastewater, and sewage secondary and tertiary treatment.

    Ø Membrane element specification

    Membrane element model

    Effective membrane area

    ft 2 (m 2 )

    Effective volume

    G( L )

    weight empty /full of water

    ( kg )

    SN U-HO-2- K200T646(60)10(38)55/121
    Inlet sizeWater outlet sizeConcentrated water outlet sizeMembrane Polymer
    DN50DN50DN50PVDF
    Membrane inner diameter/outer diameter (mm)Filtration precision (μ m )shell materialSealant material
    0.6/1.20.03pvcepoxy resin

    Ø Membrane element operating parameters

    Filtration flux ( 25℃ ) L/㎡·hr40-100
    Flow range ( 25℃ ) m³/hr2.4-6.0
    Maximum influent turbidity (NTU)≤300
    Maximum resistance to residual chlorine (NaCLO) (ppm)Continuous: 500; Momentary: 2000
    Maximum anti-suspended solid capacity (ppm)≤200
    Maximum influent COD (ppm)100
    Working temperature (℃)5-40
    pH range2-11
    Maximum water production (L/m³·h)140
    Maximum water inlet pressure ( 20°C ) (Mpa)0.25
    Maximum transmembrane pressure difference (Mpa)0.2
    Maximum backwash pressure (Mpa)0.2
    Maximum air flushing flow rate (Nm³/hr)12
    General backwash cycle (min)15-60
    General backwash time (sec)30-60
    General backwash flow rate (L/m³·h)100-350
    General chemical enhanced backwash cycle (day)1-15
    General chemical backwashing time (min)1-15
    General chemical cleaning cycle (day)30-180
    General chemical cleaning time (min)90-480
    General chemical cleaning chemicalsNaClO or H2O2 20 00ppm , NaOH (PH≤10), HCl ( PH≥2 )
    How to run /operateoutside-in / full flow or cross flow filtration
    Expected water production SDI≤3
    Expected product water turbidity NTU≤0.2
    Bacteria removal rate (log)>6
    E. coli removal rate (log)>6
    service life≥3 years under standard conditions


    LL1L2L3L4Diameter Φair intake
    2340mm2000mm2130mm2320mm160mm344mmRP 3/8”
    (92.1)in(78.7)in(83.9)in(91.3)in(6.2)in(13.5)in/

    Ø Membrane element operation guide

    During the operation of the UF system, it is necessary to avoid sudden changes in pressure during system start-up, shutdown, operation, cleaning, maintenance, etc., as well as exceeding the maximum pressure specified in this manual, to prevent possible membrane breakage, sealing, etc. End fall off, membrane shell cracking and other serious damage consequences; this series of products have been treated with anti-corrosion and membrane wire protection before leaving the factory, and the inner membrane wire of the module is in a semi-dry state. For manual operation, the water production rate should be set to 50% of the design water production rate, and the initial water production must be discharged directly and cannot be used as product water.

    Ø Membrane element product usage tips

    The normal start-up and normal cleaning and maintenance of the UF system are the key to ensure the long-term normal use of membrane products. Before starting the system, it should be ensured that the parameters of each valve, instrument, pre-processing equipment, signal transmission equipment, power equipment, etc. meet the design specifications and requirements, so as to ensure the safe, stable and up-to-standard operation of the overall system. Please refer to the product technical manual for the debugging and testing work of the system in the early stage.

    Ø Disclaimer

    Failure to operate in strict accordance with the operating limits and guidelines set forth herein voids our limited warranty. If the UF system is out of service, please inject protective liquid inside the membrane module for anti-corrosion treatment, so as to avoid the increase of maintenance cost caused by the large number of microorganisms in the system.

    Q:How is SINOMEMB membrane different from others? A:We offer value against your money, prices which are comparatively lower, performance equivalent to best membranes available and with higher longevity. Q:Are you a manufacturer? A.Yes,we have been in providing the professional products in wire mesh field for more than 10 years. Q:How about the delivery time? A:Usually within7-10days,customized order may need longer time.

    Quality Compact Hollow Fiber Ultrafiltration Membrane 80L / M2 / H Easy Maintenance for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Sinomemb Environment Technology (beijing) Co.,
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Ultrafiltration Membrane products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0