Sign In | Join Free | My burrillandco.com
Home >

5 Core SWA Armoured Electrical Cable 1.5-400mm2 IEC 60502-1 BS5467 Standard

    Buy cheap 5 Core SWA Armoured Electrical Cable 1.5-400mm2 IEC 60502-1 BS5467 Standard from wholesalers
     
    Buy cheap 5 Core SWA Armoured Electrical Cable 1.5-400mm2 IEC 60502-1 BS5467 Standard from wholesalers
    • Buy cheap 5 Core SWA Armoured Electrical Cable 1.5-400mm2 IEC 60502-1 BS5467 Standard from wholesalers

    5 Core SWA Armoured Electrical Cable 1.5-400mm2 IEC 60502-1 BS5467 Standard

    Ask Lasest Price
    Brand Name : Zhongdong
    Model Number : VV72
    Certification : ISO,VDE,ISO,TUV
    Price : Negotiable
    Payment Terms : L/C,T/T
    Supply Ability : 100KM/Week
    Delivery Time : 10 Work days
    • Product Details
    • Company Profile

    5 Core SWA Armoured Electrical Cable 1.5-400mm2 IEC 60502-1 BS5467 Standard

    5 Core SWA Armoured Electrical Cable 1.5-400mm2 IEC 60502-1 BS5467 Standard


    APPLICATION

    This product is suitable for power transmission and distribution in lines rated voltage not exceeding 0.6/1kV.


    CONSTRUCTION

    • Conductor: Class 1/Class 2 stranded Copper conductor
    • Insulation: Polyvinyl chloride (PVC)
    • Filler(options):Polypropylene mesh tearing rope
    • Inner sheath:Polyvinyl chloride (PVC)
    • Armour:Aluminum wire or stainless steel wire(single core)galvanized steel wire(multi core)
    • Outer sheath:Polyvinyl chloride (PVC)



    CHARACTERISTIC

    • Voltage Rating Uo/U: 0.6/1kV
    • Maximum operating temperature of conductor:+90℃
    • Operating ambient temperature: -20℃~+45
    • Cable laying temperature:Not less than 0℃(When the ambient temperature is below 0℃, the cable should be preheated.)
    • Minimum Bending Radius: 12D (D is the actual outer diameter of the cable)

    Specification

    Specs
    mm²

    Conductor diameter
    mm

    Nominal thickness of insulation
    mm

    Lining thickness
    mm

    Nominal thickness of steel wire
    mm

    Nominal thickness of sheath
    mm

    Approximate outer diameter of cable
    mm

    Approximate cable weight
    kg/km

    5×1.5

    1.38

    0.8

    1

    0.8

    1.8

    16.7

    468

    5×2.5

    1.78

    0.8

    1

    0.8

    1.8

    17.8

    553

    5×4

    2.25

    1

    1

    1.25

    1.8

    21.1

    867

    5×6

    2.76

    1

    1

    1.25

    1.8

    22.5

    1032

    5×10

    4

    1

    1

    1.6

    1.8

    26.5

    1518

    5×16

    5

    1

    1

    1.6

    1.8

    29.2

    1932

    5×25

    6.1

    1.2

    1

    1.6

    1.9

    33.7

    2632

    5×35

    7.2

    1.2

    1.2

    2

    2

    38.2

    3559

    5×50

    8.4

    1.4

    1.2

    2

    2.2

    43

    4495

    5×70

    10

    1.4

    1.2

    2

    2.3

    47.5

    5756

    5×95

    12

    1.6

    1.4

    2.5

    2.5

    55.9

    8080

    5×120

    13

    1.6

    1.4

    2.5

    2.7

    59

    9457

    5×150

    14.9

    1.8

    1.6

    2.5

    2.9

    66

    11477

    5×185

    16.5

    2

    1.6

    2.5

    3

    71.7

    13732

    5×240

    18.4

    2.2

    1.8

    3.15

    3.3

    80.3

    18105

    5×300

    21

    2.4

    1.8

    3.15

    3.6

    89

    22013

    5×400

    23.4

    2.6

    1.8

    3.15

    3.9

    97.2

    27030

    ABOUT US

    PACKAGE



    APPLICATION



    PROJECT

    Armored STA 3 Core Electrical Cable Wire Flame Retardant IEC60502-1 IEC 60332 Standard Cable 4
    WHY US

    Armored STA 3 Core Electrical Cable Wire Flame Retardant IEC60502-1 IEC 60332 Standard Cable 5

    FAQ

    What is the typical application of this cable?
    Mainly used for power distribution in industrial plants, underground installations, and outdoor environments requiring robust protection.

    How is the armor layer constructed?
    The steel wire armor consists of interlocking steel wires helically wound around the insulated cores, offering both tensile strength and rodent resistance.

    What are the core materials used?
    Conductors are typically made of stranded copper or aluminum, with PVC or XLPE insulation for each core.

    Is this cable suitable for direct burial?
    Yes, the SWA design makes it ideal for direct burial without additional conduit, though local regulations should be verified.

    What bending radius should be maintained during installation?
    Minimum bending radius is generally 12 times the cable's outer diameter to prevent armor deformation.

    How does the armor affect cable weight?
    The steel wire armor increases weight by approximately 30-50% compared to non-armored equivalents.

    What termination methods are recommended?
    Use gland fittings compatible with SWA armor to ensure proper grounding and strain relief.

    What maintenance is required for this cable?
    Regular visual inspections for armor damage or corrosion, especially in harsh environments



    Quality 5 Core SWA Armoured Electrical Cable 1.5-400mm2 IEC 60502-1 BS5467 Standard for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Zhongdong Cable Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Armoured Electrical Cable products from this supplier
    Inquiry Cart 0