COMEN battery CMLI1X3N002B is an original replacement for the COMEN C50 multi-parameter critical care monitor. This brand-new battery is fully compatible with the device, offers long battery life, and is safe to use. It provides continuous and stable power to the monitor in situations such as unreliable power outages, sudden utility outages, and patient transport, ensuring uninterrupted real-time monitoring of critical patient vital signs.
Battery Compatibility
This battery is only compatible with the COMEN C50 multi-parameter intensive care monitor.
Lifespan and Warranty
The battery has a cycle life of ≥500 cycles and a storage life of 2 years in a standard environment. If unused for extended periods (>3 months), recharge to 50%-60% every 2 months to prevent damage.
Typical Usage Scenarios
Intra-hospital transport of critically ill patients, long-distance ambulance visits, ICU emergency backup, and special environment monitoring.
| Brand | Comen Medical |
|---|---|
| Model | CMLI1X3N002B |
| Battery Type | Li-ion |
| Voltage | 11.1V |
| Capacity | 5.2Ah |
| Energy | 57.72Wh |
| Working current | 1.0-1.5A |
| Charging time | 2.5-3hours |
| Charging temperature limit | 0-40℃ |
| Color | White |
| Size | 140mm*75mm*35mm |
| Weight | About 450g |
Q1: While transporting a patient by ambulance, the monitor suddenly displays "Battery Low," but the hospital is still 20 minutes away. What should I do?
A1: You can use the "Reducing Power Consumption to Extend Battery Life" feature as an emergency measure. Disable non-essential monitoring parameters, such as temporarily stopping automatic non-invasive blood pressure measurement and reducing screen brightness to 30%. If there are no backup batteries, prioritize heart rate and blood oxygen monitoring, closely monitor the patient's consciousness and respiratory status, and contact the hospital's emergency department to prepare for the patient's arrival. This will minimize the time it takes to connect data after transport.
Q2: After the battery is fully charged, the monitor displays "Battery Health 75%" when installed and in use. Does this indicate a battery failure?
A2: "Battery Health 75%" does not indicate a failure; it is a normal indicator of natural battery capacity degradation. This battery is designed for 350 cycles. After about a year of use, the health level will drop from 100% to 80-75%. As long as the battery life still meets basic clinical needs, it does not need to be replaced.
Q3: I'm using the Coman C50 monitor charger to charge this battery, but the charger indicator light isn't on and the battery won't charge. Is the battery damaged?
A3: This is most likely due to charger incompatibility, not battery damage. This battery requires the original C30 charger (12.6V DC/1.5A output), while the C50 monitor charger outputs 14.8V DC/2A. The voltage, current, and interface protocols differ. We recommend replacing the original C30 charger and trying again. If charging still fails, check the battery connector for cleanliness or damage.

|