Sign In | Join Free | My burrillandco.com
Home > Filter Supplies >

ESR Blood Collection Tube with Room-Temperature Storage Bionic Active Membrane and Black Cap for Clinical Diagnostics

    Buy cheap ESR Blood Collection Tube with Room-Temperature Storage Bionic Active Membrane and Black Cap for Clinical Diagnostics from wholesalers
     
    Buy cheap ESR Blood Collection Tube with Room-Temperature Storage Bionic Active Membrane and Black Cap for Clinical Diagnostics from wholesalers
    • Buy cheap ESR Blood Collection Tube with Room-Temperature Storage Bionic Active Membrane and Black Cap for Clinical Diagnostics from wholesalers
    • Buy cheap ESR Blood Collection Tube with Room-Temperature Storage Bionic Active Membrane and Black Cap for Clinical Diagnostics from wholesalers

    ESR Blood Collection Tube with Room-Temperature Storage Bionic Active Membrane and Black Cap for Clinical Diagnostics

    Ask Lasest Price
    Brand Name : Orsin
    Model Number : Gel Clot ActivatoR
    Certification : ISO 13485
    Price : Negotiation
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 20million/pcs/moth
    Delivery Time : 1-4 weeks
    • Product Details
    • Company Profile

    ESR Blood Collection Tube with Room-Temperature Storage Bionic Active Membrane and Black Cap for Clinical Diagnostics

    Orsin Medical Technology ESR Blood Collection Tubes

    Orsin Medical Technology presents its high-precision Erythrocyte Sedimentation Rate (ESR) Blood Collection Tubes, engineered for accuracy and reliability in clinical diagnostics.

    These vacuum-evacuated tubes are specifically designed for the precise measurement of the Erythrocyte Sedimentation Rate, a critical marker for detecting and monitoring inflammatory activity, infections, and chronic diseases.

    Product Highlights: Technological Innovation Ensures Accuracy

    ESR tubes incorporate advanced engineering to deliver superior clinical performance:

    Feature CategoryTechnical SpecificationClinical Value
    Contamination PreventionClosed vacuum system; direct blood transfer to anticoagulant tubeEliminates operator exposure; reduces lab contamination; complies with biosafety standards
    Operational EfficiencyDistinctive black cap; pre-measured anticoagulant; ready-to-useStreamlines workflow; reduces sampling errors
    Result Precision0.129mol/ L(anticoagulant:blood=1:4); concentration-controlledEnsures consistent anticoagulation; prevents ESR deviations
    System CompatibilityCompatible with major automated ESR analyzers (e.g., ESR-30/40); LIS/HIS integrationEnhances lab efficiency; reduces transcription errors
    Interference ResistanceSpecialized anticoagulant minimizes effects of icteric/hemolyzed/lipemic samplesExpands detectable sample range; improves reliability in pathological states

    Usage Precautions: Standardized Operations Ensure Reliability

    3.1 Pre-collection Preparation

    • Tube Selection: Verify black-capped ESR-specific tubes contain 3.8% sodium citrate. Inspect for particulates, sedimentation, or cap looseness.

    • Storage Conditions: Store at 4-25°C. Avoid freezing (causes tube fracture) or high temperatures (degrades anticoagulant).

    • Patient Preparation: Collect blood from calm, preferably fasting patients. Note non-fasting status on requisition forms.

    3.2 Blood Collection Protocol

    • Order of Draw: Follow international sequence: blood culture → coagulation tubes → other anticoagulant tubes → ESR tubes (black cap). Prevents anticoagulant cross-contamination.

    • Exact Fill Volume: Draw precisely to fill line (typically 2mL). Underfilling causes false-low ESR; overfilling promotes microclot formation.

    • Mixing Technique: Gently invert 5-10 times immediately after collection. Avoid vigorous shaking to prevent partial anticoagulation or hemolysis.

    3.3 Post-collection Handling

    • Testing Timeline: Analyze within 2 hours. Delayed testing alters erythrocyte morphology. Store at 18-25°C if necessary (NEVER refrigerate).

    • Tube Orientation: Transport upright to avoid disturbing sedimentation.

    • Sample Rejection Criteria: Reject clotted, severely hemolyzed, improperly filled (>±10%), unlabeled, or damaged specimens.

    *Note: 30% of ESR errors originate from pre-analytical issues, primarily inaccurate fill volumes and improper mixing.*

    Technical Specifications: Standard-Compliant Parameters

    arameter CategorySpecification Detail
    Intended UseFor the collection of venous blood and the measurement of Erythrocyte Sedimentation Rate (ESR).
    AnticoagulantTri-Sodium Citrate (Na<sub>3</sub>C<sub>6</sub>H<sub>5</sub>O<sub>7</sub> · 2H<sub>2</sub>O)
    Concentration3.2% (0.109 Molar) or 3.8% (Note: 3.2% is the ICSH international standard)
    Blood to Additive Ratio4:1 (e.g., 1.6 mL draw volume with 0.4 mL citrate)
    Tube SizeCommon sizes: 13x75 mm, 16x100 mm
    Draw VolumeCommon volumes: 1.8 mL, 2.4 mL, 2.7 mL, 4.5 mL
    Tube MaterialClear PET (Polyethylene Terephthalate) or Glass
    Closure ColorBlack (ISO 6710 & CLSI Standard)
    SterilitySterilized by Radiation (SAL 10<sup>-6</sup>)
    Endotoxin Level≤ 0.5 EU/mL (As per USP/EP standards)
    Shelf LifeTypically 12-24 months from date of manufacture.

    Key Features:

    • Optimized Anticoagulant: Pre-filled with a 3.2% concentration of Tri-Sodium Citrate, ensuring the ideal blood-to-anticoagulant ratio for consistent and clinically accurate ESR results.

    • International Compliance: Features a distinct black closure for instant, unambiguous identification according to global ISO 6710 standards, enhancing safety and workflow efficiency in the lab.

    • Superior Clarity: Manufactured from high-quality, clear glass or PET plastic for excellent sample visibility and minimal interference.

    • Safety and Reliability: Each batch undergoes rigorous quality control to ensure sterility, consistent vacuum pressure, and clot-free sample collection.

    Quality ESR Blood Collection Tube with Room-Temperature Storage Bionic Active Membrane and Black Cap for Clinical Diagnostics for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shanghai Orsin Medical Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Vacuum Blood Test Tube products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0