Sign In | Join Free | My burrillandco.com
Home > Home Product Making Machinery >

Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants

    Buy cheap Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants from wholesalers
     
    Buy cheap Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants from wholesalers
    • Buy cheap Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants from wholesalers

    Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants

    Ask Lasest Price
    Brand Name : Yokogawa
    Model Number : RC800D
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 1000 Piece/Pieces per Week negotiable
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants

    Providing reliable chlorine measurements in Water Treatment Plants since 1959
    No.1 Process analyzer supplier to Japanese market*

    "Reliable Chlorine monitoring and minimize Chlorine injection"

    "Continuous automatic cleaning and achieved less maintenance time"

    "Maintenance remotely and reduce maintenance time"

    Many of our customers face these challenges - Yokogawa Chlorine Analyzers resolve them.

    The RC800D residual chlorine analyzer employs a polarographic system that uses rotating platinum electrodes to provide a continuous online measurement of residual chlorine concentration. It is possible to separate residual chlorine (free chlorine + combined-chlorine) from free chlorine for measurements by appropriate use of reagents.

    The RC800D is suitable for various water condition measurements and gives you a stable and high-quality measurement thanks to the rotation electrodes and superior reagent pump.

    The RC800D is intended for water distribution measurements at pumping stations, water delivery points, schools, and public facilities.
    *Based on a Yokogawa survey in 2019

    Features

    Easy to clean cell structure, Module motor unit, and Sensor health and motor check

    • Amperometric measurement of free chlorine or total chlorine (polarographic method)
    • Measure Free chlorine or residual chlorine (total chlorine) continuously in water
    • Unique rotation electrode method keeps sensor clean and reduces maintenance cycle
    • Superior reagent pump realizes stable measurement regardless of sample conditions
    • Easy maintenance structure, modularized motor unit, and diagnostics functions strongly support regular maintenance
    • Remote wash and calibration functions are available
    • RC800D is equipped with Manual calibration and Auto Calibration, 2 points correction, Basic (reference) sensitivity calibration, and circuit open Zero calibration
    • Remote range switching is available
    RC800D Left

    RC800D display:easy to use touch screen

    Structure

    TC8000D Structure

    Application

    Each process at treatment plant: from reservoir to treated water, distribution system

    Water Purification Treatment

    • Stabilization
    • Flocculation
    • Settling Basins
    • Chlorination
    • Clean water reservoir
    • Distributing pump
    • Distribution tank & Piping


    Use case


    Specifications

    Measured ObjectFree chlorine or residual chlorine (total chlorine) in water
    Measuring SystemAmperometric method (Polarographic method) using rotating electrode
    Measuring Range0-10 mg/L
    Sample ConditionsTemperature0 to 50°C (Temperature compensation is effective within 0 to 40°C)
    pH3 to 9
    Flow Rate1 to 4 L/min, for pure water or municipal water application.
    5 to 10 L/min, for raw water or sea water application.
    10 to 20 L/min, for secondary sewage treatment application.
    Pressure20 to 500 kPa
    Power Supply100 to 240 V DC, 50/60 Hz
    Digital CommunicationModbus TCP/IP, Modbus RTU
    InstallationIndoor (Outdoor use requires protection against rain. Direct sunlight must be avoided.)


    Performance

    Linearity±3% of reading or ±0.03 mg/L whichever is greater
    Repeatability±1% of reading or ±0.01 mg/L whichever is greater


    Quality Reagent Type Residual Chlorine Sensor with 0-10 mg/L Measuring Range and 100-240 V DC Power Supply for Water Treatment Plants for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xi'an Kacise Optronics Co.,Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Water Quality Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0