Sign In | Join Free | My burrillandco.com
Home > Lab Supplies >

Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output

    Buy cheap Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output from wholesalers
     
    Buy cheap Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output from wholesalers
    • Buy cheap Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output from wholesalers

    Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output

    Ask Lasest Price
    Brand Name : Merrytek
    Model Number : KE028-02AM180HE
    Certification : CE, UKCA, UN38.3,MSDS
    Price : Negotiation
    Payment Terms : T/T or Western Union
    Supply Ability : 10,000pcs per month
    Delivery Time : 1, Sample and small order: Within 5 working days after receiving your payment. 2, Bulk order: 3-4 weeks after receiving deposit.
    • Product Details
    • Company Profile

    Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output

    Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output


    1. Description


    1) Constant power output LED emergency power supply with a wide output voltage range.
    2) Input relay switching.
    3) High safety, high performance, long life LifePO4 battery.
    4) With battery management.

    5) Manual check and self-check selection.


    2. Parameters

    Charge PartKE02802AM180HE03AM180HE04AM180HE05AM180HE
    Rated input voltage220-240Vac 50Hz/60Hz
    Rated input current0.06A Max. @230Vac
    Input inrush current10A(Twidth=100us 50% Ipeak )@230Vac(Cold start at full load )
    Power factor≥0.5@230Vac
    Input power<4W@230Vac
    Battery charging current200mA200mA350mA350mA
    Battery charging time24 hours Max.
    Emergency PartOperating modeEmergency mode
    Load typeLED
    Emergency power2W2.5W4W5W
    Emergency time3hours
    Load output current25-10mA31-12mA50-20mA57-23mA
    Load output voltage80-200Vdc
    BatteryLifePO4 (The battery capacity meets the emergency time at 25℃)6.4V 1.8Ah6.4V 1.8Ah6.4V 3.6Ah6.4V 3.6Ah
    Battery warrantyWarranty 5 years @5~60℃.
    Exception Driver RequirementsSurge current8A
    Input current3A Max.
    Output current2A Max.
    LED Indication
    (Manual test)
    ChargingGreen light
    FaultGreen light off
    Emergency Function TestManual testDefault
    Auto testSettable
    Auto TestingFault/test / StatusReasonCharge Indicator Status
    The battery is fully charged and operationalStandard daily use
    solid green
    Battery ChargingInitial Charge/Battery Top Up
    Flashing green 1 sec on 1 sec off
    Auto Test 3 Hours (every 12 months)Periodic self-test
    Flashing Green 3 sec on 1 sec off
    Auto Test 5 Min (every 30 days)Periodic self-test
    Flashing Green 3 sec on 3 sec off
    Duration test faultAutomatic test failed
    Flashing Red 0.5 sec on 0.5 sec off
    LED faultNot plugged in or damaged/faulty
    Flashing Red 2 sec on – 2 sec off
    Battery Disconnected/FaultyNot plugged in or damaged/faulty
    solid red
    Emergency protectionBattery over-charge/deep discharge protectionYes
    Output over-voltage protectionYes
    Output overload protectionYes
    Output short circuit protectionYes

    Operating

    Environment

    Operating temperature/humidity0℃…+50℃, Humidity: 20%-75%(without condensation)
    Storage temperature/humidity-5℃-35℃
    Case Max. Temp(Tc)75℃

    Safety

    & EMC


    Withstand voltage3000Vac 5mA 60s (Input “L N” – output “SEC+ SEC-)
    Safety standardEN61347-1, 60598-2-22, 61347-2-7, 62034
    EMC standardEN55015, EN61000-3-2, EN61000-3-3
    Battery standardUN38.3
    Environmental protection requirementsCompliant with RoHS
    CertificationCE
    OthersInput/output(terminal/wiring) specificationPress terminal, wire diameter: 0.5-0.75mm2
    IP ratingIP20
    Type of protectionClass 2
    Installation typeBuilt-in installation
    Installation dimension146*30*22.5mm
    Packaging requirementWhite box+Instruction manual+clapboard+outer carton(K=A)
    Weight75g (driver)
    Lifespan5 Year @Ta

    Notes:

    All parameters are tested on the input voltage 230Vac, environment temperature 25℃, unless otherwise specified.


    3. Dimension (Unit: mm)


    4. Battery Dimension (Unit: mm)

    Fig. A Fig. B

    Fig. C Fig. D


    5. Wiring Diagram


    OR


    6. Manual and Automatic Test Set Exchange


    7. Wire Preparation

    1)Solid or Stranded wire type: 0.5 -0.75mm2

    2)To access or remove the wires from the terminals, use a screwdriver to push the buttons down


    8. Manual Test & Operation Instructions

    1) Before installation, set Pin short: Manual Test.

    2) Connect the wire according to the wiring diagram.

    3) L, N power on, Switch on S1. Then the load lamp turns on, the emergency driver indicator light turns green, emergency power supply is normal charging. Turn off Switch S1, and the load lamp turns off.

    4) Emergency Simulation: Switch on, the load lamp turns on, press the switch(TEST SWITCH), then switch to emergency mode, the indicator light of the emergency driver will be extinguished. Release the switch(TEST SWITCH), then the lamp is powered by the LED driver, and the indicator light will turn on.


    9. Automatic Test & Operation Instructions

    1) Before installation, set Pin open: Automatic Test.

    2) Connect the wire according to the wiring diagram. Remove the test switch on the LED Emergency Driver.

    3) L, N power on, start the clock, and periodic self-test. To replace the battery, turn off the power supply, and Re-time.


    10. Battery Application Notice

    1) The battery should be recharged and discharged semiannually in normal use conditions.

    2) Do not connect to the circuit when the battery is not in use to prevent over-discharge of the battery due to self-consumption of the circuit board.

    3) Please keep the battery away from the heat source when installing and using it, and only allow it to be used in a certain working temperature range.

    4) The battery should be stored in a cool and dry environment.

    5) After long-term storage, the battery is cycled every 12 months as required.

    6) AC power is off, and the clock lasts for 7 days. Power on and re-time. To replace the battery, turn off the power supply, and Re-time.


    Quality Self-check 2W LED conversion kits with 3 hours duration time and 80-200Vdc output for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Merrytek Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more LED Emergency Driver products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0