Sign In | Join Free | My burrillandco.com
Home > Paper Chemicals >

2.0 mL ESR Blood Collection Tube - 12000pcs/hour Room Temperature

    Buy cheap 2.0 mL ESR Blood Collection Tube - 12000pcs/hour Room Temperature from wholesalers
     
    Buy cheap 2.0 mL ESR Blood Collection Tube - 12000pcs/hour Room Temperature from wholesalers
    • Buy cheap 2.0 mL ESR Blood Collection Tube - 12000pcs/hour Room Temperature from wholesalers

    2.0 mL ESR Blood Collection Tube - 12000pcs/hour Room Temperature

    Ask Lasest Price
    Brand Name : Orsin
    Model Number : Gel Clot ActivatoR
    Certification : ISO 13485
    Price : Negotiation
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 20million/pcs/moth
    Delivery Time : 1-4 weeks
    • Product Details
    • Company Profile

    2.0 mL ESR Blood Collection Tube - 12000pcs/hour Room Temperature

    Orsin Medical Technology ESR Blood Collection Tubes

    Orsin Medical Technology presents its high-performance ESR Blood Collection Tubes, engineered to deliver precision and reliability in erythrocyte sedimentation rate testing. Designed for the Westergren method, our tubes ensure accurate diagnostic results with enhanced safety and efficiency.

    Product Highlights: Technological Innovation Ensures Accuracy

    ESR tubes incorporate advanced engineering to deliver superior clinical performance:

    Feature CategoryTechnical SpecificationClinical Value
    Contamination PreventionClosed vacuum system; direct blood transfer to anticoagulant tubeEliminates operator exposure; reduces lab contamination; complies with biosafety standards
    Operational EfficiencyDistinctive black cap; pre-measured anticoagulant; ready-to-useStreamlines workflow; reduces sampling errors
    Result Precision0.129mol/ L(anticoagulant:blood=1:4); concentration-controlledEnsures consistent anticoagulation; prevents ESR deviations
    System CompatibilityCompatible with major automated ESR analyzers (e.g., ESR-30/40); LIS/HIS integrationEnhances lab efficiency; reduces transcription errors
    Interference ResistanceSpecialized anticoagulant minimizes effects of icteric/hemolyzed/lipemic samplesExpands detectable sample range; improves reliability in pathological states

    Usage Precautions: Standardized Operations Ensure Reliability

    3.1 Pre-collection Preparation

    • Tube Selection: Verify black-capped ESR-specific tubes contain 3.8% sodium citrate. Inspect for particulates, sedimentation, or cap looseness.

    • Storage Conditions: Store at 4-25°C. Avoid freezing (causes tube fracture) or high temperatures (degrades anticoagulant).

    • Patient Preparation: Collect blood from calm, preferably fasting patients. Note non-fasting status on requisition forms.

    3.2 Blood Collection Protocol

    • Order of Draw: Follow international sequence: blood culture → coagulation tubes → other anticoagulant tubes → ESR tubes (black cap). Prevents anticoagulant cross-contamination.

    • Exact Fill Volume: Draw precisely to fill line (typically 2mL). Underfilling causes false-low ESR; overfilling promotes microclot formation.

    • Mixing Technique: Gently invert 5-10 times immediately after collection. Avoid vigorous shaking to prevent partial anticoagulation or hemolysis.

    3.3 Post-collection Handling

    • Testing Timeline: Analyze within 2 hours. Delayed testing alters erythrocyte morphology. Store at 18-25°C if necessary (NEVER refrigerate).

    • Tube Orientation: Transport upright to avoid disturbing sedimentation.

    • Sample Rejection Criteria: Reject clotted, severely hemolyzed, improperly filled (>±10%), unlabeled, or damaged specimens.

    *Note: 30% of ESR errors originate from pre-analytical issues, primarily inaccurate fill volumes and improper mixing.*

    Technical Specifications: Standard-Compliant Parameters

    CategorySpecificationDetails
    Intended UseFor the in-vitro collection of venous blood and measurement of Erythrocyte Sedimentation Rate (ESR) by the Westergren method.
    AnticoagulantTypeTri-Sodium Citrate (3.2% or 3.8%)
    Concentration0.109 mol/L or 0.129 mol/L
    Ratio4:1 (Blood to Anticoagulant)
    Volume0.4 mL anticoagulant for 1.6 mL blood draw
    Tube DesignMaterialBorosilicate Glass or PET Plastic
    Dimensions13 x 100 mm (Standard Westergren) or 13 x 75 mm
    Total Volume2.0 mL or 2.5 mL
    GraduationPrecision scale from 0 to 200 mm
    ClosureSafety-engineered, latex-free stopper
    PerformanceSterilitySterilized by Gamma Irradiation or ETO
    Endotoxins< 20 EU/tube
    Vacuum Accuracy±10% of nominal draw volume
    Shelf Life24 months from date of manufacture
    Storage & HandlingTemperatureRoom Temperature (15-30°C / 59-86°F)
    HandlingProtect from direct sunlight. Do not freeze.
    Stability after drawTest within 4-6 hours (RT) or 12-24 hours (refrigerated)
    ComplianceStandardsCE Marked. Complies with relevant EU IVD Directive.

    Orsin Medical Technology's ESR tubes are engineered for precision and compliance in erythrocyte sedimentation rate testing.


    Quality 2.0 mL ESR Blood Collection Tube - 12000pcs/hour Room Temperature for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shanghai Orsin Medical Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Vacuum Blood Test Tube products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0