Sign In | Join Free | My burrillandco.com
Home > Laser Equipment >

Safety-engineered, latex-free stopper 1.28 mL ESR Interference Resistance

    Buy cheap Safety-engineered, latex-free stopper  1.28 mL ESR Interference Resistance from wholesalers
     
    Buy cheap Safety-engineered, latex-free stopper  1.28 mL ESR Interference Resistance from wholesalers
    • Buy cheap Safety-engineered, latex-free stopper  1.28 mL ESR Interference Resistance from wholesalers

    Safety-engineered, latex-free stopper 1.28 mL ESR Interference Resistance

    Ask Lasest Price
    Brand Name : Orsin
    Model Number : Gel Clot ActivatoR
    Certification : ISO 13485
    Price : Negotiation
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 20million/pcs/moth
    Delivery Time : 1-4 weeks
    • Product Details
    • Company Profile

    Safety-engineered, latex-free stopper 1.28 mL ESR Interference Resistance

    Orsin Medical Technology ESR Blood Collection Tubes

    Orsin Medical Technology's ESR tube is a vacuum blood collection system specifically designed for the Erythrocyte Sedimentation Rate (ESR) test. It features a pre-filled, precise amount of liquid sodium citrate anticoagulant to ensure a correct 4:1 blood-to-anticoagulant ratio, which is critical for accurate and reliable test results.

    Engineered for safety and efficiency, the tube includes a safety-engineered stopper and is made from clear, break-resistant glass or PET plastic for optimal sample visibility. It is ideal for clinical laboratories seeking consistent performance in hematology testing.

    Product Highlights: Technological Innovation Ensures Accuracy

    ESR tubes incorporate advanced engineering to deliver superior clinical performance:

    Feature CategoryTechnical SpecificationClinical Value
    Contamination PreventionClosed vacuum system; direct blood transfer to anticoagulant tubeEliminates operator exposure; reduces lab contamination; complies with biosafety standards
    Operational EfficiencyDistinctive black cap; pre-measured anticoagulant; ready-to-useStreamlines workflow; reduces sampling errors
    Result Precision0.129mol/ L(anticoagulant:blood=1:4); concentration-controlledEnsures consistent anticoagulation; prevents ESR deviations
    System CompatibilityCompatible with major automated ESR analyzers (e.g., ESR-30/40); LIS/HIS integrationEnhances lab efficiency; reduces transcription errors
    Interference ResistanceSpecialized anticoagulant minimizes effects of icteric/hemolyzed/lipemic samplesExpands detectable sample range; improves reliability in pathological states

    To ensure the accuracy, safety, and reliability of test results, strictly adhere to the following standardized operating procedures:

    1. Correct Order of Draw

    • Precaution: If multiple tubes are being collected, the non-additive tube (e.g., serum tube) should be drawn first. The citrate tube (ESR tube) should be the second in the order of draw.

    • Ensures Reliability: Prevents cross-contamination from other anticoagulants (like EDTA or Heparin), which can significantly alter the test results and lead to erroneous ESR values.

    2. Proper Fill Volume is Critical

    • Precaution: Allow the tube to fill completely until the vacuum is exhausted. The blood volume must reach the fill mark on the tube to achieve the exact 4:1 blood-to-anticoagulant ratio.

    • Ensures Reliability: An underfilled tube has an excess of anticoagulant, which can cause hemodilution and artificially slow the sedimentation rate, producing inaccurate and unreliable results.

    3. Immediate and Thorough Mixing

    • Precaution: Gently invert the tube immediately after collection a minimum of 8-10 times.

    • Ensures Reliability: Ensures complete mixing of the blood with the sodium citrate anticoagulant. Inadequate mixing can lead to clot formation, which renders the sample unusable and requires a recollection.

    4. Adherence to Testing Timeframe

    • Precaution: The sample should be tested within 4 hours of collection if stored at room temperature. If a delay is unavoidable, the sample may be refrigerated (2-8°C or 36-46°F) for up to 12 hours, but it must be brought back to room temperature and mixed thoroughly before testing.

    • Ensures Reliability: prolonged storage at room temperature can alter the morphology and sedimentation characteristics of red blood cells, compromising the integrity of the result.

    5. Use of Dedicated Equipment

    • Precaution: Use only Westergren pipettes or automated ESR analyzers that are specifically designed and validated for use with 4:1 ratio sodium citrate tubes.

    • Ensures Reliability: Using incorrect or non-validated equipment (e.g., pipettes for different tube sizes or ratios) will produce invalid and non-standardized results.

    6. Visual Inspection Before Use

    • Precaution: Inspect the tube for damage, cracks, or expired shelf life before use. Do not use tubes if the anticoagulant appears discolored, evaporated, or crystallized.

    • Ensures Reliability: Guarantees the integrity of the vacuum and the effectiveness of the pre-filled anticoagulant, which are fundamental to obtaining a correct sample.

    7. Safety Handling

    • Precaution: Treat all samples as potentially infectious. Use standard precautions. After use, dispose of the tube and sharp in an approved sharps container.

    • Ensures Reliability: Protects the healthcare worker from exposure to bloodborne pathogens, ensuring a safe working environment. A safe procedure is a reliable and controlled procedure.

    Technical Specifications: Standard-Compliant Parameters

    CategorySpecificationDetails
    Intended UseFor the in-vitro collection of venous blood and measurement of Erythrocyte Sedimentation Rate (ESR) by the Westergren method.
    AnticoagulantTypeTri-Sodium Citrate (3.2% or 3.8%)
    Concentration0.109 mol/L or 0.129 mol/L
    Ratio4:1 (Blood to Anticoagulant)
    Volume0.4 mL anticoagulant for 1.6 mL blood draw
    Tube DesignMaterialBorosilicate Glass or PET Plastic
    Dimensions13 x 100 mm (Standard Westergren) or 13 x 75 mm
    Total Volume2.0 mL or 2.5 mL
    GraduationPrecision scale from 0 to 200 mm
    ClosureSafety-engineered, latex-free stopper
    PerformanceSterilitySterilized by Gamma Irradiation or ETO
    Endotoxins< 20 EU/tube
    Vacuum Accuracy±10% of nominal draw volume
    Shelf Life24 months from date of manufacture
    Storage & HandlingTemperatureRoom Temperature (15-30°C / 59-86°F)
    HandlingProtect from direct sunlight. Do not freeze.
    Stability after drawTest within 4-6 hours (RT) or 12-24 hours (refrigerated)
    ComplianceStandardsCE Marked. Complies with relevant EU IVD Directive.

    Key Features:

    • Precise 4:1 blood-to-anticoagulant ratio

    • Pre-filled liquid sodium citrate

    • Safety-engineered design

    • Clear material for easy sample inspection

    • Consistent and reliable ESR results


    Quality Safety-engineered, latex-free stopper  1.28 mL ESR Interference Resistance for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shanghai Orsin Medical Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Vacuum Blood Test Tube products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0