MQ136 Gas Sensor For Hydrogen Sulfide Gas Leakage Alarms
Working Principle:
The MQ136 operates based on the principle of gas adsorption on the surface of a semiconductor material. When the target gas (especially H₂S) comes into contact with the heated SnO₂ sensitive layer, the conductivity of the material changes. This change in conductivity is proportional to the concentration of the target gas, which can be converted into a measurable electrical signal through a simple circuit.
Key Features:
Applications:
Parameter | Symbol | Value | Unit | Remarks |
|---|---|---|---|---|
| Heater Voltage | Vh | 5.0V ± 0.1V | - | AC or DC |
| Loop Voltage | Vc | 5.0V ± 0.1V | - | DC |
| Heater Resistance | Rh | 30Ω ± 3Ω | - | At room temperature |
| Heater Power Consumption | Ph | ≤ 900 | mW | - |
| Detection Range | - | 10 - 1000 | ppm | For H₂S |
| Sensitivity | S | Rs (in air) / Rs (in 100ppm H₂S) ≥ 5 | - | - |
| Response Time | T90 | ≤ 10 | s | - |
| Recovery Time | T10 | ≤ 30 | s | - |
| Operating Temperature | - | -10 - 50 | ℃ | - |
| Storage Temperature | - | -20 - 70 | ℃ | - |
| Relative Humidity | - | ≤ 95 | % RH | Non-condensing |
| Pre-heat Time | - | ≥ 48 | hours | For stable performance |
| Service Life | - | ≥ 5 | years | - |

|