Sign In | Join Free | My burrillandco.com
Home >

H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas

    Buy cheap H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas from wholesalers
     
    Buy cheap H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas from wholesalers
    • Buy cheap H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas from wholesalers
    • Buy cheap H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas from wholesalers
    • Buy cheap H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas from wholesalers
    • Buy cheap H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas from wholesalers
    • Buy cheap H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas from wholesalers
    • Buy cheap H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas from wholesalers

    H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas

    Ask Lasest Price
    Model Number : H2-1000
    Price : Negotiable
    Payment Terms : L/C, D/A, D/P, T/T, Western Union, MoneyGram
    Supply Ability : 5000PCS
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas


    H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas


    Product Features:

    • High Sensitivity and Resolution: Capable of detecting low-concentration hydrogen gas, with resolutions as low as 0.1 ppm (depending on the specific model), ensuring accurate monitoring even at trace levels.
    • Wide Measurement Range: Typically covers 0 - 1000 ppm, with a maximum overload capacity of up to 2000 ppm, adapting to various hydrogen concentration detection scenarios.
    • Fast Response: Features a short response time, with T90 (time to reach 90% of the final value) generally less than 90 seconds (some models can be as fast as less than 30 seconds), enabling quick detection of hydrogen leaks.
    • Good Stability: Exhibits low baseline drift and long-term output drift (e.g., < 2% signal/month), ensuring reliable and consistent measurement results over extended periods.
    • Robust Environmental Adaptability: Operates within a wide temperature range (e.g., -20°C to 50°C or even -40°C to 55°C) and humidity range (15 - 90% RH non-condensing), suitable for use in harsh or varying environmental conditions.
    • Long Service Life: Depending on the model, the expected operating life can reach more than 2 years (some up to over 5 years) in clean air, reducing the frequency of replacement and maintenance costs.
    • Low Cross-sensitivity: Has minimal interference from other gases (e.g., low cross-sensitivity to carbon monoxide in some models), ensuring measurement accuracy for hydrogen.
    • Compact and Lightweight: Small in size (e.g., Φ20 x 16.6 mm) and light in weight (generally less than 10 g), making it easy to integrate into various detection devices.

    Product Applications:

    • Industrial Safety: Used in hydrogen production plants, hydrogen storage facilities, and hydrogen transportation systems to monitor hydrogen leaks in real-time, preventing potential safety hazards such as explosions or fires.
    • Fuel Cell Systems: Applied in fuel cell-powered devices (e.g., fuel cell vehicles, backup power systems) to detect hydrogen concentrations, ensuring the safe and efficient operation of the fuel cell system.
    • Laboratory and Research: Utilized in laboratories for hydrogen gas concentration analysis in experiments, providing accurate data support for scientific research.
    • Medical Equipment: In some medical devices involving hydrogen, it is used to monitor hydrogen levels to ensure the safety of medical procedures and equipment operation.
    • Domestic Safety: Integrated into household gas detection systems to alert residents in a timely manner if hydrogen leaks occur in home environments (e.g., from hydrogen-based appliances), ensuring family safety.

    Measurement Range0 - 1000 ppm
    Maximum Measurement Limit2000 ppm
    Sensitivity0.4 ± 0.2 (nA/ppm)
    Response Time (T90)<60 seconds
    Baseline Range (20℃)±10 ppm
    Zero - point Drift (-20℃ - 40℃)±20 ppm
    Repeatability2%

    Quality H2-1000 Gas Sensor Is Mainly Used To Detect Hydrogen Gas for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: ShenzhenYijiajie Electronic Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Gas Sensor products from this supplier
    Inquiry Cart 0