Sign In | Join Free | My burrillandco.com
Home >

ASTM D6304 E1064 Karl Fischer Moisture Meter ISO 10337 Karl Fischer Micro Moisture Analyzer

    Buy cheap ASTM D6304 E1064 Karl Fischer Moisture Meter ISO 10337 Karl Fischer Micro Moisture Analyzer from wholesalers
     
    Buy cheap ASTM D6304 E1064 Karl Fischer Moisture Meter ISO 10337 Karl Fischer Micro Moisture Analyzer from wholesalers
    • Buy cheap ASTM D6304 E1064 Karl Fischer Moisture Meter ISO 10337 Karl Fischer Micro Moisture Analyzer from wholesalers

    ASTM D6304 E1064 Karl Fischer Moisture Meter ISO 10337 Karl Fischer Micro Moisture Analyzer

    Ask Lasest Price
    Brand Name : Lonroy
    Model Number : LR-Q430
    Certification : ISO ASTM CE
    Price : Negotaible
    Payment Terms : L/C,D/A,D/P,T/T,Western Union
    Supply Ability : 200
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    ASTM D6304 E1064 Karl Fischer Moisture Meter ISO 10337 Karl Fischer Micro Moisture Analyzer

    ASTM D6304 E1064 Karl Fischer Moisture Meter ISO 10337 Karl Fischer Micro Moisture Analyzer

    Introduction

    The Karl Fischer micro moisture analyzer is automatically controlled by a single-chip microcomputer. It has self-diagnosis for system failures, a color liquid crystal touch screen, a full Chinese menu, and a more user-friendly interface. It automatically subtracts the blank current, has high accuracy in test results, a large current background compensation function, significantly shortened standby time, a unique reagent failure detection function, and automatically reminds users to replace the failed reagents in time, thereby greatly improving the utilization rate of the reagents. It has built-in multiple calculation formulas for moisture content, which meets the needs of different users.

    Product Features

    1. This instrument is automatically controlled by a single-chip microcomputer, with self-diagnosis for system faults;

    2. Color LCD touch screen, with full Chinese menus, providing a more user-friendly interface;

    3. Automatic blank current deduction, resulting in highly accurate test results;

    4. Function for detecting expired reagents, automatically alerting users to replace the expired reagents in time;

    5. Equipped with an efficient micro printer, with a built-in large-capacity memory, facilitating customers to review and print test reports;

    Execution Standards

    GB/T 6283-2008 Method for Determining Moisture Content in Chemical Products - Karl Fischer Method

    ASTM E1064-2008 Karl Fischer Coulometric Titration Method for Determining Moisture Content in Organic Liquids

    GB/T 7600-1987 Method for Determining Moisture Content in Transformer Oil during Operation (Coulometric Method)

    ASTM D4928-00(2010) Karl Fischer Coulometric Titration Method for Determining Moisture Content in Crude Oil

    ASTM D6304-2007 Karl Fischer Coulometric Titration Method for Determining Water Content in Petroleum Products, Lubricants and Additives

    ISO 10337-1997 Method for Determining Moisture Content in Crude Oil - Karl Fischer Coulometric Titration Method

    GB/T 11146-2009 Method for Determining Moisture Content in Crude Oil - Karl Fischer Coulometric Titration Method

    GB/T 3727-2003 Determination of Trace Moisture in Industrial Ethylene and Propylene (Micro-Coulometric Method)

    GB/T 5074-1985 Micro-Coulometric Method for Determining Moisture Content in Pyrolysis Products

    GB/T 6023-2008 Determination of Trace Moisture in Industrial Butadiene - Karl Fischer Coulometric Method

    GB/T 7376-2008 Determination of Trace Moisture in Industrial Fluorinated Alkane Compounds - Karl Fischer Method

    GB/T 18619.1-2002 Determination of Moisture Content in Natural Gas - Karl Fischer Coulometric Method

    GB/T 18826-2002 Industrial 1,1,1,2-Tetrafluoroethane HFC-134a

    SH/T 0246-1992 Method for Determining Moisture Content in Light Petroleum Products (Electrical Method)

    SH/T 0255-1992 Electrical Method for Determining Moisture Content in Additives and Lubricating Oils Containing Additives

    ASTM E1064-2008 Karl Fischer Coulometric Titration Method for Determining Moisture Content in Organic Liquids

    ASTM D4928-00(2010) Karl Fischer Coulometric Titration Method for Determining Moisture Content in Crude Oil

    ASTM D6304-2007 Karl Fischer Coulometric Titration Method for Determining Water Content in Petroleum Products, Lubricants and Additives and other method standards;

    Application Scope

    Chemical Industry: Alcohols, ethers, acids, benzene derivatives, phenols, organic solvents, etc. applicable for determination by Karl Fischer method

    Petroleum and Power Industry: Insulating oil, transformer oil, etc. oil products

    Pharmaceutical Industry: Pharmaceutical raw materials, etc. Pesticide Industry: Emulsifiers, fertilizers, pesticides, etc.

    Food and Beverage, Surfactants, Cosmetics

    Other Industries: Lithium battery electrolyte, etc.


    Technical specifications

    Model

    LR-Q430

    Display

    Large screen LCD display or touchscreen

    Determination principle

    Karl-Fischer coulometric method (also known as electrolysis method)

    Measurement voltage

    Double platinum electrodes, constant current polarization detection

    Electrolysis current

    Automatic pulse current 400mA

    Blank current

    Real-time detection of reagent moisture absorption and intuitive display, automatically deducted

    Stirring speed

    Stepless speed adjustment

    Determination range

    0.1μg - 200mg; 1ppm - 100%

    Sensitivity

    0.1μg

    Accuracy

    3μg - 500μg: ±3 μg; Above 500μg: 0.3% (excluding sample error)

    Automatic printing

    Built-in high-efficiency low-noise line thermal printer

    Result display

    Multiple calculation formulas, automatically display moisture%, ppm, mg/L, etc.

    Instrument self-check

    Fault self-diagnosis, intuitive reminder to users

    Titration delay

    Adjustable determination delay time (0 - 999 seconds); ensures complete release of sample moisture before detection for higher accuracy

    Reagent life

    Automatic tracking of reagent consumption, automatic reminder when expired

    System calibration

    Built-in calibration program; calibrates via standard samples; enables software micro-adjustment of system gain coefficient to correct to accurate value

    Analysis speed

    Users can freely select electrolysis speed according to analysis requirements

    History records

    Can store 500 records (with sample number and time mark) for user query and printing

    Power supply voltage

    AC 220V ± 10% 50HZ ± 5%

    Size and weight

    Dimensions: 350mm * 320mm * 160mm; Net weight: 6kg


    Quality ASTM D6304 E1064 Karl Fischer Moisture Meter ISO 10337 Karl Fischer Micro Moisture Analyzer for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: DONGGUAN LONROY EQUIPMENT CO LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Small Meter products from this supplier
    Inquiry Cart 0