Sign In | Join Free | My burrillandco.com
Home > Woodworking Machinery >

Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side

    Buy cheap Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side from wholesalers
     
    Buy cheap Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side from wholesalers
    • Buy cheap Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side from wholesalers
    • Buy cheap Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side from wholesalers
    • Buy cheap Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side from wholesalers

    Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side

    Ask Lasest Price
    Brand Name : TENCAN
    Model Number : GBP1000S-3
    Certification : CE ISO
    Price : Negotiable
    Payment Terms : T/T, Western Union
    Supply Ability : 100 sets per month
    Delivery Time : 25-35 working days After getting deposit
    • Product Details
    • Company Profile

    Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side

    China Tencan Glove Box With Purification System Single Side for Water and Oxygen Removal


    Brief Introduction


    The Purification System Glove Box is a laboratory device designed to infuse its chamber with high-purity inert gas and simultaneously purify it by eliminating active impurities. Commonly known as a "vacuum glove box for water and oxygen extraction" or an "inert gas purification glove box," its main functions include the removal of water, oxygen, and other organic gases. This glove box is widely employed to establish a high-purity, contamination-free environment free from water, oxygen, and dust particles.


    Working principle


    The box and purification system are integrated to establish a securely enclosed operational area. By consistently infusing inert gas or nitrogen into the box, it enables the continuous extraction of active substances in a cyclical manner, thereby ensuring that the interior maintains an exceptional level of cleanliness and a consistent high-purity inert gas atmosphere, with water content kept at 1 ppm or below and oxygen content limited to 1 ppm or less.


    Structure Principle


    The Purification System Glove Box primarily consists of two essential components: the main box body and a transition chamber. We offer customized designs and specifications to meet our clients' unique requirements.

    The main box body features two or more glove operation interfaces on its front or back side, enabling simultaneous operation by one or multiple operators, thus enhancing the efficiency of using the glove box. Furthermore, observation windows are incorporated on either the front or back, offering clear visibility of the operational processes inside the box. Air suction and charging nozzles are located on the valves of the transition chamber, facilitating the extraction or introduction of air as needed. Additionally, the main box body is equipped with a valve and nozzle that can be used to maintain an air pressure balance inside the box whenever necessary.

    The transition chamber serves as an intermediary space between the main box body and the external environment, comprising two sealing doors, two valves, and a chamber body. Both sealing doors effectively isolate the interior of the main box body from the outside, allowing for seamless transfer of items in and out of the box while maintaining an isolated atmosphere, thereby eliminating the need for repeated evacuation and inflation procedures.


    Applications


    Applies to making pure environment with removal of water, oxygen and dust.

    R&D and production of battery industry (Lithium ion battery, powder battery, solar cell, lithium ion phosphate battery ).

    R&D and manufacture of special lamp (HD lamp, metal halide lamp, ceramic metal halide lamp).

    Welding (resistance welding, TIG welding, laser welding, plasma welding, brass solder)

    R&D and production of OLED

    R&D and production of pharmaceuticals

    R&D and production of super capacitors

    Fine chemical industry

    Nuclear industry

    R&D and production of new energy materials


    Specifications


    Specifications of Standard Model of Purification Glove Box
    No.Model No.Box DimensionsTotal DimensionsOperating Sides

    Numbers

    of Gloves

    Options
    1GBP800S-21200*800*930mm1915*830*1830mmSingle2Single or double purification columns
    2GBP1000S-21200*1000*930mm1915*1060*1830mmSingle2Single or double purification columns
    3GBP1000D-41200*1000*930mm1915*1060*1830mmDouble4Single or double purification columns
    4GBP1200S-21200*1200*930mm1915*1260*1830mmSingle2Single or double purification columns
    5GBP1200D-41200*1200*930mm1915*1260*1830mmDouble4Single or double purification columns
    6GBP800S-31500*800*930mm2215*1060*1830mmSingle3Single or double purification columns
    7GBP1000S-31500*1000*930mm2215*1060*1830mmSingle3Single or double purification columns
    8GBP1000D-61500*1000*930mm2215*1060*1830mmDouble6Single or double purification columns
    9GBP1200S-31500*1200*930mm2215*1260*1830mmSingle3Single or double purification columns
    10GBP1200D-61500*1200*930mm2215*1260*1830mmDouble6Single or double purification columns
    11GBP800S-41900*800*930mm2615*1060*1830mmSingle4Single or double purification columns
    12GBP1000S-41900*1000*930mm2615*1060*1830mmSingle4Single or double purification columns
    13GBP1000D-81900*1000*930mm2615*1060*1830mmDouble8Single or double purification columns
    14GBP1200S-41900*1200*930mm2615*1260*1830mmSingle4Single or double purification columns
    15GBP1200D-81900*1200*930mm2615*1260*1830mmDouble8Single or double purification columns

    Notes:
    Cabinet water and oxygen content under the standard condition:

    The acceptable water content is limited to 1 ppm or less, and the oxygen content must not exceed 1 ppm (Note: These specifications are measured under standard conditions of atmospheric pressure and a constant temperature of 20°C).
    Leakage Rate: ≤0.05Vol%/ h (subject to change value of oxygen content in box)
    Used Gas:
    a) Working Gas: N2,Ar,He and etc.
    b) Controlling Gas: Compressed air or Inert Gas.
    C) Restoring Gas: Mixed gas of working gas and hydrogen.
    Restoring gas is as same as working gas if there is only water removal system or oxygen removal system.
    Note: An assembled glove box system comprises single-sided boxes, each equipped with four gloves, and the number of these boxes can be tailored to meet customer requirements. Additionally, the purification columns are specifically designed in quantities that exactly match each customer's specifications.


    Technical Parameters


    TECHNICAL DATA OF TENCAN INERT GAS GLOVE BOX WITH PURIFICATION SYSTEM
    ItemsData
    Water content under the standard condition (Note: The standard condition is one atmospheric pressure, constant temperature of 20 degrees)≤1ppm

    The measurement of oxygen content is conducted under standardized conditions: one atmosphere of pressure and a consistent temperature maintained at 20 degrees Celsius.

    ≤1ppm
    Max Vacuum Degree which the transition cabinet bears<100pa
    Leakage Rate≤ 0.05vol%/h
    Gas presure range inside the box-3000pa~+3000pa

    Functions


    FUNCTIONS OF TENCAN INERT GAS GLOVE BOX WITH PURIFICATION SYSTEM
    ItemsDescriptions
    Automatic ControlControlled and monitored automatically by the program control unit.
    Box body gas replacement
    (manual/automatic)

    Before starting up, the cabinet's air needs to be swapped out for inert gas or nitrogen. This process can be efficiently executed through the cabinet's system-integrated automatic gas replacement feature, or it can be done manually as a secondary option.

    Transition cabinet replacement
    (manual/automatic

    Upon placing material in a box, it necessitates the replacement of the gas transition cabinet. This can be achieved by either utilizing the airlock system's automatic gas exchange function or by manually carrying out the gas replacement.

    Gas purification control

    After setting up the work status and results, the system purification procedures set to “Auto”, the system will automatically maintain the atmosphere condition of the cabinet,then the system will automatically complete the work; you may also choose manual control.

    Pedal air-pressure control

    Operate the foot controller to regulate gas pressure within the cabinet by controlling the inflation or exhaust system.

    Reduction of purification system

    After setting the reduction parameters, the system assumes control over the purification material reduction process. With a simple "reduce" command, the system manages the entire procedure independently, negating the need for human supervision.

    On-line operating condition detection

    The control system provides users with the operating condition detection function of the component of the equipment. Such function can be used to observe operating condition of the component and inspect fault source of each function and component.

    System parameter setting

    System settings function, users can set the system parameters to achieve the desired working conditions and feature set.

    Data logging function

    The system provides operating parameter record of the equipment, this record can be traced back to monitor production or experiment.

    Control of gas reserve function

    When the temporary cutting of control-gas supply, or cutting off control-gas source for some time, the control-gas reserve will protect the equipment continue working.

    Standby function of cycle gas cooled

    The purification system includes a heat exchange process that cools the circulating gas, enabling it to function standalone by utilizing coolant injection to manage the temperature of the circulating gas.

    Multi-level safety system

    The control system is equipped with various security features, encompassing multilevel safety warnings, alarms, and deactivation capabilities, aimed at safeguarding both the operators and the equipment.

    Protection function when purification
    cycle blocked

    Upon detecting an obstruction in the circulation system, the control system initiates alerts and proactively modifies the air speed to protect the motor. Furthermore, this feature has the capability to identify problems including blocked system cycles, inadequate piping, obstructions in filter controls due to dust, and various other associated issues.



    Quality Gas Management Systems Inert Chemistry Laboratory Glove Boxes With Water And Oxygen Removal 3kpa Single Side for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Changsha Tianchuang Powder Technology Co., Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Inert Gas Glove Box products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0