Sign In | Join Free | My burrillandco.com
Home >

Spare And Wear Part V3560170-0100 V3568985-0100 For ALSTOM OPTIPULS Pulse Valve V2549810-0300 V2549810-0400

    Buy cheap Spare And Wear Part V3560170-0100 V3568985-0100 For  ALSTOM OPTIPULS Pulse Valve  V2549810-0300  V2549810-0400 from wholesalers
     
    Buy cheap Spare And Wear Part V3560170-0100 V3568985-0100 For  ALSTOM OPTIPULS Pulse Valve  V2549810-0300  V2549810-0400 from wholesalers
    • Buy cheap Spare And Wear Part V3560170-0100 V3568985-0100 For  ALSTOM OPTIPULS Pulse Valve  V2549810-0300  V2549810-0400 from wholesalers
    • Buy cheap Spare And Wear Part V3560170-0100 V3568985-0100 For  ALSTOM OPTIPULS Pulse Valve  V2549810-0300  V2549810-0400 from wholesalers

    Spare And Wear Part V3560170-0100 V3568985-0100 For ALSTOM OPTIPULS Pulse Valve V2549810-0300 V2549810-0400

    Ask Lasest Price
    Brand Name : ALSTOM , AIRWOLF
    Model Number : V3560170-0100 (Nitrile),V3568985-0100 (fluororubber)
    Price : price negotiable
    Payment Terms : T/T in advance,Western Union,Paypal,Credit card
    Supply Ability : 2000 pcs
    Delivery Time : within 1-30 working days after payment
    • Product Details
    • Company Profile

    Spare And Wear Part V3560170-0100 V3568985-0100 For ALSTOM OPTIPULS Pulse Valve V2549810-0300 V2549810-0400

    Spare and wear part V3560170-0100 V3568985-0100 for ALSTOM OPTIPULS Pulse valve V2549810-0300 V2549810-0400


    Diaphragm code : V3560170-0100 ,max.90°C fitted for ALSTOM OPTIPULS Pulse valve V2549810-0300
    Diaphragm code : V3568985-0100 ,max.120°C fitted for ALSTOM OPTIPULS Pulse valve V2549810-0400



    1 . The design with integral compression fittings will facilitate installation because there is no need for threaded piping

    2 . The high quality diaphragms are reinforced and wear resistant to guarantee a long operating life, even under harsh conditions

    3 . Integral pilot operated valves satisfy all relevant EC directives

    4 . The pulse diaphragm valves are especially designed for dust collector service applications, combining high flow, long life and extremely fast opening and closing to produce reliable and economical operation.

    5 . The high flow, angle type bodies in combination with the special main diaphragm assemblies give the unique operating features required for dust collector service applications


    Competitive Advantage:


    Our product features:Our Services Guarantee:
    1) Competitive price1) Prompt respond (Reply with 24 hours)
    2) Good quality2) Free Samples (Customer pay for the delivery cost)
    3) Professional Packaging,3) Registration support.
    4) Produce according to Customers’ instruction4) Photos/videos are available during production.
    5) None delay shipment

    5) Loading inspection, and send loading photos before shipment.



    The installment introduction:
    1. First, Confirm the pulse valve in good condition and then installed
    2. Pulse valve will be installed directly the outer wall of flange of gas manifold. The spray pipe across the gas manifold. According to the drawing and manual, the pulse valve matching appropriate spray pipe and installation. To avoid the valve install in the air manifold bottom. If the pulse valve matched trachea and connector, the connector will be used for sealing purpose only. It can not as structural support components. It can not rely on the straight connector fixed spray torch and package. The spray pipe and air manifold must be fixed independent.
    3. To tighten the hard nut, the maximum torque of 20 N*m.Tighten the trachea, torsion of 20 N*m.
    4. The connection control wire needs connect of every electric control valve seat. Pay attention to the line adown to prevent rain waterproof. Or through the joint and nylon pipe, it will connect the pulse valve and electromagnetic assembly boxes of nylon pipe connection.
    5. To ensure that provide compressed air clean and dry. The air manifold system provides moderate pressure and check for leaks installation. ( it can brush on soap and water, check whether the interface is bubble). Pressure was carried out on the air bag inflated (pressure of the valve is around 0.03 ~ 0. 86 mpa), recommend for air pressure 0.8 mpa maximum
    6. Testing the pulse valve blowing, listening all the pilot valve whether it is normal operation and whether the pulse blowing sound is clear.


    Product Tags:

    V3560170-0100

      

    V3568985-0100

      
    Quality Spare And Wear Part V3560170-0100 V3568985-0100 For  ALSTOM OPTIPULS Pulse Valve  V2549810-0300  V2549810-0400 for sale
    Company Info.
    Airwolf Automation
    Verified Supplier
    View Contact Details
    Product List
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ