| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | wanyuan |
| Certification : | ISO9001,ISO14001,ISO45001 |
| Price : | Negotiable |
| Delivery Time : | Negotiable according to customer requirements |
| Payment Terms : | L/C, D/P, T/T, Western Union |
| Supply Ability : | Negotiable according to customer requirements |
Water Treatment Two Stage RO System , Industrial Reverse Osmosis Machine
The two-stage reverse osmosis system is an efficient water
treatment solution designed for industrial applications. With the
use of advanced reverse osmosis technology, this system is capable
of significantly improving the water purification capacity through
a two-stage treatment process.
The first stage of this system utilizes pretreatment to remove
large particle impurities from the raw water. The second stage uses
high-performance reverse osmosis membranes to further remove
dissolved solids, heavy metals and microorganisms to ensure that
the effluent quality meets industry standards.
This system is widely used in electronics, pharmaceuticals, food
and beverage and other fields, and can effectively meet the demand
for high-purity water.
Pretreatment: The raw water first passes through the pretreatment
equipment to remove suspended solids, sediments and other large
particle impurities to protect the subsequent reverse osmosis
membrane.
First-stage reverse osmosis: The pretreated water enters the first
reverse osmosis unit. Under the action of the high-pressure pump,
water molecules pass through the reverse osmosis membrane,
dissolved solids and contaminants are intercepted, and pure water
flows out.
Second-stage reverse osmosis: The first-stage reverse osmosis water
then enters the second reverse osmosis unit to further remove
residual contaminants and improve water quality.
Water output and monitoring: The high-purity water finally obtained
is tested in real time by a water quality monitor to ensure that it
meets the predetermined water quality standards.
Efficient impurity removal: can remove more than 95% of dissolved
solids, heavy metals, organic matter and bacteria.
Water quality improvement: provide high-quality pure water that
meets international standards to meet various industrial needs.
Wastewater reuse: achieve industrial wastewater treatment and
recycling, and promote the sustainable use of water resources.
Real-time monitoring: equipped with water quality monitoring
instrument to monitor the water quality at any time to ensure water
safety.
The system design for water treatment includes a raw water tank to store the water, a raw water pump to move the water through the system, a pretreatment process to remove impurities, a reverse osmosis process for further purification, and a production water tank to store the purified water. All of these components work together to ensure that the water meets the required standards for use in various industries.
The two-stage reverse osmosis design creates a high water treatment efficiency and produces a higher quality water output.
The structure employs a skid design, making it incredibly easy to maintain and replace, ultimately leading to lower operating costs.
The intelligent control system supports remote monitoring and management, making operation easier for the user.
The system has low failure rates and a decreased maintenance and replacement frequency ensuring strong stability and consistent operation.
The system provides high-purity water and meets strict industrial water quality standards.
The efficient water treatment and resource reuse are more environmentally friendly, leading to reduced energy requirements and resource conservation.
Maximum Operating Temperature: The highest temperature that this particular system can operate at
is 45℃. This is important to keep in mind while configuring this
system for continuous operation. If the temperature exceeds 45℃, it
could lead to system damage or failure.
Maximum Operating Pressure: The maximum operating pressure for this system is 41bar. This
means that the pressure cannot exceed this limit while the system
is in operation. It is vital to monitor the system pressure
regularly to ensure that it doesn't surpass 41bar.
Maximum Pressure Drop: The maximum pressure drop for this system is restricted to only
1bar. It is important to note that the pressure drop can occur when
the supply pressure falls below the operating pressure required by
the system. A pressure drop beyond the set limit can lead to system
malfunctioning and poor performance.
PH Value Range (Continuous Operation): The continuous operating range of PH values for this system is
between 2 to 11. Therefore, any external factor that affects the PH
values should be monitored, like adding pH stabilizers to the
system to prevent the values from going beyond the set limit.
PH Value Range (Short-Term Cleaning): For short-term cleaning of the system, the safety range of PH
values is limited between 1 to 13. It should be kept in mind that
any potential deviation in this range can alter the product's
chlorine tolerance and functionality.
Maximum Water Flow Rate: The maximum water flow rate for this system is 4040 3.6t/h and
8040 19t/h. This means that the water flow rate should not cross
the given limits. The flow rate should be monitored to ensure that
it does not exceed the maximum limit, which could cause significant
damage to the system.
Maximum Water Supply SDI: The maximum water supply SDI that can be allowed while using this
system is 5. It is necessary to monitor the water quality, as a
higher SDI level could cause severe damage to the system's
membranes, resulting in poor performance and reduced lifespan.
Allowable Free Chlorine Content: While using this system, the permissible level of free chlorine
content is restricted to only 0.1ppm. This level should be
constantly monitored to avoid any chemical incompatibility with the
system material and prevent any damage or potential risks.
In the chemical industry, water is needed for the treatment of cooling water and reaction water to ensure the stability of the production process. Without proper treatment, the water used in chemical processes can contain impurities that negatively impact the quality of the end product.
The production of food and beverages requires purified water to ensure that products meet food safety standards. Contaminated water can result in serious health issues for consumers, so it's crucial to have a reliable water purification system in place.
The pharmaceutical industry requires high-purity water that meets the strict requirements of drug production. This is to ensure the safety and effectiveness of drugs. Any impurity in the water can have a significant impact on the quality of the drugs and can lead to serious consequences for patients.
The electronic industry requires ultrapure water for the production of electronic components. The production process requires an extremely clean environment, and the water used in the process must meet high purity standards to avoid any contamination that could affect product quality or performance.
The environmental protection industry is responsible for implementing sewage reuse to support enterprises' environmental protection and resource conservation. This is crucial for sustainable development practices and reducing the impact of industrial production on the environment.
|