Sign In | Join Free | My burrillandco.com
Home > Outdoor Sports >

Fluke 1586A Super-DAQ Precision Temperature Scanner F1586A

    Buy cheap Fluke 1586A Super-DAQ Precision Temperature Scanner F1586A from wholesalers
     
    Buy cheap Fluke 1586A Super-DAQ Precision Temperature Scanner F1586A from wholesalers
    • Buy cheap Fluke 1586A Super-DAQ Precision Temperature Scanner F1586A from wholesalers

    Fluke 1586A Super-DAQ Precision Temperature Scanner F1586A

    Ask Lasest Price
    Brand Name : Fluke
    Model Number : Fluke 1586A Super-DAQ Precision Temperature Scanner F1586A
    Certification : CCCI
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 1000pcs
    Delivery Time : 15-20days
    • Product Details
    • Company Profile

    Fluke 1586A Super-DAQ Precision Temperature Scanner F1586A

    Specifications: Fluke 1586A Super-DAQ Precision Temperature Scanner

    General Specifications
    Mains Voltage 100 V Setting: 90 V to 110 V
    120 V Setting: 108 V to 132 V
    220 V Setting: 198 V to 242 V
    240 V Setting: 216 V to 264 V
    Frequency 47 Hz to 440 Hz
    Power Consumption 36 VA peak (24 W average)
    Environment Temperature Operating: 0 °C to 50 °C
    Full accuracy: 18 °C to 28 °C
    Storage: −20 °C to 70 °C
    Warm-up: 1 hour to full accuracy specifications
    Relative Humidity (non-condensing) Operating: 0 °C to 30 °C <80 %;
    30 °C to 50 °C <50 %
    Storage: −20 °C to 70 °C <95 %
    Altitude Operating: 2,000 m
    Storage: 12,000 m
    Vibration and Shock Complies with MIL-PRF-28800F Class 3
    Channel Capacity Total analog channels: 45
    Voltage/resistance channels: 41
    Current channels: 5
    Digital I/O: 8 bits
    Totalizer: 1
    Alarm outputs: 6
    Trigger input: 1
    Channel Input Connector Types 1586A Channel 001 (front panel): gold pins, bare wire, spade lugs, banana plugs
    DAQ-STAQ Multiplexer: gold pins, bare wire, mini spade lugs, mini banana plugs, mini-jack thermocouple
    High-Capacity Module: gold pins, bare wire
    Input Protection 50 V all functions, terminals and ranges
    Math Channels Number of channels: 20
    Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum
    Triggers interval, external (trigger input), alarm, remote (bus), manual, automated test
    Memory Scan data RAM: 75,000 readings with timestamp
    Data/Setup flash memory: 20 MB
    USB Host Port Connector type: Type A
    Function: Memory
    File system: FAT32
    Memory capacity: 32 GB
    USB Device Port Connector type: Type B
    Class: Instrument
    Function: Control and data transfer
    Command protocol: SCPI
    LAN Function: Control and data transfer
    Network protocols: Ethernet 10/100, TCP/IP
    Command protocol: SCPI
    RS-232 Connector: D-sub 9 pin (DE-9)
    Baud rates: 1200, 2400, 4800, 9600, 19200, 38400
    Function: Temperature source control output
    Dimensions Height: 150 mm
    Width: 245 mm
    Depth: 385 mm Weight: 6 kg (typical configuration)
    Shipping Weight: 9.5 kg (typical configuration)
    Conformity CE, CSA, IEC 61010 3rd ed.
    Measurement Specifications
    Accuracy specifications generally apply with medium and slow sample rates (unless otherwise noted), after a warm-up time of 1 hour, and within an environment temperature range of 18 °C to 28 °C, and may depend on the channel. The confidence level for accuracy specifications is 95 % within 1 year of calibration.
    Scan rate Fast: 10 channels per second max (0.1 seconds per channel) Medium: 1 channel per second (1 second per channel)
    Slow: 4 seconds per channel
    Display Resolution 6 1/2 digits (see Measurement Characteristics tables below to find the display resolution of temperature readings)
    PRT/RTD
    Temperature Range −200 °C to 1200 °C (depending on the sensor)
    Resistance Range 0 Ω to 4 kΩ
    Offset Compensation 0 Ω to 400 Ω, 4-wire: automatic current reversal
    400 Ω to 4000 Ω or 3-wire: none
    Source Current Reversal Interval (0 Ω to 400 Ω range) Fast sample rate: 2 ms
    Medium sample rate: 250 ms
    Slow sample rate: 250 ms
    Maximum Lead Resistance (4-wire Ω) 2.5 % of range per lead for 400 Ω and 4 kΩ ranges
    PRT/RTD Resistance Accuracy
    Accuracy is given as % of measurement or ohms, whichever is greater. Basic accuracy is for 4-wire PRT/RTD. When using 3-wire PRT/RTD add 0.013 Ω to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.05 Ω if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
    Range Sample Rate DAQ-STAQ Module and Channel 1 High-Capacity Module T.C./ °C Outside 18 °C to 28 °C
    0 Ω to 400 Ω Slow 0.002 % or 0.0008 Ω 0.003 % or 0.003 Ω 0.0001 % or 0.0008 Ω
    Medium 0.002 % or 0.002 Ω 0.003 % or 0.003 Ω 0.0001 % or 0.0008 Ω
    Fast 0.002 % or 0.005 Ω 0.003 % or 0.006 Ω 0.0001 % or 0.0008 Ω
    400 Ω to 4 kΩ Slow 0.004 % or 0.06 Ω 0.006 % or 0.06 Ω 0.0001 % or 0.008 Ω
    Medium 0.004 % or 0.1 Ω 0.006 % or 0.1 Ω 0.0001 % or 0.008 Ω
    Fast 0.004 % or 0.18 Ω 0.006 % or 0.18 Ω 0.0001 % or 0.008 Ω
    PRT/RTD Temperature Accuracy
    Accuracy is for 4-wire 100 Ω nominal PRT/RTD. When using 3-wire PRT/RTD add 0.039 °C to the accuracy specification for internal resistance mismatch and voltage offset if using Channel 1, or add 0.15 °C if using channels x01 through x20. If the environment temperature is outside the specified range, multiply the temperature coefficient number by the temperature deviation and add to the accuracy specification. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor and characterization.
    Sample Rate Temperature DAQ-STAQ Module and Channel 1 High-Capacity Module T.C./ °C Outside 18 °C to 28 °C
    Slow −200 °C 0.002 °C 0.008 °C 0.002 °C
    0 °C 0.005 °C 0.008 °C 0.003 °C
    300 °C 0.012 °C 0.018 °C 0.006 °C
    600 °C 0.02 °C 0.03 °C 0.01 °C
    Medium −200 °C 0.005 °C 0.008 °C 0.002 °C
    0 °C 0.005 °C 0.008 °C 0.003 °C
    300 °C 0.012 °C 0.018 °C 0.006 °C
    600 °C 0.02 °C 0.03 °C 0.01 °C
    Fast −200 °C 0.013 °C 0.015 °C 0.002 °C
    0 °C 0.013 °C 0.015 °C 0.003 °C
    300 °C 0.014 °C 0.018 °C 0.006 °C
    600 °C 0.02 °C 0.03 °C 0.01 °C
    PRT/RTD Measurement Characteristics
    Temperature Display Resolution
    Range Slow / Medium Sample Rate Fast Sample Rate Source Current
    0 Ω to 400 Ω 0.001 °C 0.01 °C ±1 mA
    400 Ω to 4 kΩ 0.001 °C 0.01 °C 0.1 mA
    Thermistor
    Temperature Range −200 °C to 400 °C (depending on the sensor)
    Resistance Range 0 Ω to 1 MΩ
    Thermistor Resistance Accuracy
    Accuracy is given as ± (% of measurement + Ω). The basic accuracy specification is for 4-wire thermistor, slow sample rate. When using medium or fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification. For 2-wire thermistor add 0.02 Ω internal resistance if using Channel 1 or
    1.5 Ω if using channels x01 through x20, and add external lead wire resistance.
    Range Slow Sample Rate Medium Sample Rate Rate Fast Sample Rate T.C./ °C Outside18 °C to 28 °C
    0 Ω to 2.2 kΩ 0.004 % + 0.2 Ω add 0.3 Ω add 1 Ω 0.0005 % + 0.05 Ω
    2.1 kΩ to 98 kΩ 0.004 % + 0.5 Ω add 0.5 Ω add 1.3 Ω 0.0005 % + 0.1 Ω
    95 kΩ to 1 MΩ 0.015 % + 5 Ω add 5 Ω add 13 Ω 0.001 % + 2 Ω
    Thermistor Temperature Accuracy
    Accuracy specifications are for 4-wire thermistor. When using 2-wire thermistor, add the number given in the table to the specification for internal resistance. If the environment temperature is outside the specified range, increase the accuracy specification by 25 % for every 1 °C outside the specified environment temperature range. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor.
    Accuracy 2.2 kΩ Thermistor
    Temperature SlowSample Rate MediumSample Rate FastSample Rate 2-wire
    −40 °C 0.001 °C 0.001 °C 0.01 °C add 0.001 °C
    0 °C 0.003 °C 0.004 °C 0.01 °C add 0.004 °C
    25 °C 0.006 °C 0.011 °C 0.02 °C add 0.016 °C
    50 °C 0.008 °C 0.018 °C 0.04 °C add 0.05 °C
    100 °C 0.047 °C 0.114 °C 0.28 °C add 0.34 °C
    150 °C 0.23 °C 0.56 °C 1.34 °C add 1.7 °C
    Accuracy 5 kΩ Thermistor
    Temperature Slow Sample Rate Medium Sample Rate Fast Sample Rate 2-wire
    −40 °C 0.003 °C 0.004 °C 0.01 °C add 0.001 °C
    0 °C 0.002 °C 0.002 °C 0.01 °C add 0.002 °C
    25 °C 0.004 °C 0.006 °C 0.01 °C add 0.007 °C
    50 °C 0.005 °C 0.009 °C 0.02 °C add 0.022 °C
    100 °C 0.022 °C 0.052 °C 0.13 °C add 0.16 °C
    150 °C 0.096 °C 0.24 °C 0.57 °C add 0.7 °C
    Accuracy 10 kΩ Thermistor
    Temperature Slow Sample Rate Medium Sample Rate Fast Sample Rate 2-wire
    −40 °C 0.003 °C 0.004 °C 0.01 °C add 0.001 °C
    0 °C 0.002 °C 0.002 °C 0.01 °C add 0.002 °C
    25 °C 0.003 °C 0.004 °C 0.01 °C add 0.004 °C
    50 °C 0.005 °C 0.009 °C 0.02 °C add 0.011 °C
    100 °C 0.011 °C 0.024 °C 0.06 °C add 0.067 °C
    150 °C 0.04 °C 0.098 °C 0.24 °C add 0.29 °C
    Thermistor Measurement Characteristics
    Temperature Display Resolution
    Range Slow / Medium
    Sample Rate
    Fast
    Sample Rate
    Source Current
    0 Ω to 2.2 Ω 0.0001 °C 0.001 °C 10 μA
    2.1 Ω to 98 Ω 0.0001 °C 0.001 °C 10 μA
    95 Ω to 1 MΩ 0.0001 °C 0.001 °C 1 μA
    Thermocouple
    Temperature Range −270 °C to 2315 °C (depending on the sensor)
    Voltage Range −15 mV to 100 mV
    Thermocouple Voltage Accuracy
    Accuracy is given as ± (|% of measurement| + μV). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
    Range Accuracy Channel 1 Ch. x01 – x20 Fast Sample Rate T.C./ °C Outside
    18 °C to 28 °C
    −15 mV to 100 mV 0.004 % + 4 μV add 2 μV add 1 μV 0.0005 % + 0.0005 mV
    Thermocouple Reference Junction Accuracy
    Module CJC Accuracy T.C./ °C Outside
    18 °C to 28 °C
    DAQ-STAQ Module 0.25 °C 0.02 °C
    High-Capacity Module 0.6 °C 0.05 °C
    Thermocouple Temperature Accuracy
    Accuracy specifications apply using medium or slow sample rate. When using fast sample rate, increase the accuracy specification by 25 %. If the environment temperature is outside the specified range, increase the accuracy specification by 12 % for every 1 °C outside the specified environment temperature range. Accuracy with fixed/external CJC does not include the accuracy of the reference junction temperature. Linear interpolation may be used between points in the table. Specifications do not include sensor accuracy. The practical range of temperature measurement depends on the sensor.
    Type
    (Range)
    Temperature Accuracy
    Fixed / External CJC Internal CJC
    Channel 1 Ch. x01 – x20 DAQ-STAQ Module High-Capacity
    Module
    K
    −270 °C to
    1372 °C
    −200 °C
    0 °C
    1000 °C
    0.28 °C
    0.10 °C
    0.14 °C
    0.41 °C
    0.15 °C
    0.20 °C
    0.76 °C
    0.29 °C
    0.32 °C
    1.60 °C
    0.62 °C
    0.64 °C
    T
    −270 °C to
    400 °C
    −200 °C
    0 °C
    200 °C
    400 °C
    0.27 °C
    0.10 °C
    0.08 °C
    0.08 °C
    0.40 °C
    0.15 °C
    0.12 °C
    0.11 °C
    0.76 °C
    0.30 °C
    0.23 °C
    0.20 °C
    1.60 °C
    0.65 °C
    0.47 °C
    0.41 °C
    R
    −50 °C to
    1768 °C
    0 °C
    300 °C
    1200 °C
    1600 °C
    0.76 °C
    0.42 °C
    0.33 °C
    0.34 °C
    1.13 °C
    0.63 °C
    0.47 °C
    0.49 °C
    1.16 °C
    0.64 °C
    0.48 °C
    0.50 °C
    1.28 °C
    0.71 °C
    0.52 °C
    0.54 °C
    S
    −50 °C to
    1768 °C
    0 °C
    300 °C
    1200 °C
    1600 °C
    0.74 °C
    0.45 °C
    0.37 °C
    0.39 °C
    1.11 °C
    0.67 °C
    0.54 °C
    0.56 °C
    1.14 °C
    0.68 °C
    0.55 °C
    0.57 °C
    1.26 °C
    0.76 °C
    0.60 °C
    0.63 °C
    J
    −210 °C to
    1200 °C
    −200 °C
    0 °C
    1000 °C
    0.20 °C
    0.08 °C
    0.11 °C
    0.29 °C
    0.12 °C
    0.14 °C
    0.65 °C
    0.28 °C
    0.25 °C
    1.41 °C
    0.61 °C
    0.53 °C
    N
    −270 °C to
    1300 °C
    −200 °C
    0 °C
    500 °C
    1000 °C
    0.42 °C
    0.15 °C
    0.12 °C
    0.14 °C
    0.62 °C
    0.23 °C
    0.17 °C
    0.19 °C
    0.90 °C
    0.34 °C
    0.24 °C
    0.26 °C
    1.69 °C
    0.64 °C
    0.44 °C
    0.45 °C
    E
    −270 °C to
    1000 °C
    −200 °C
    0 °C
    300 °C
    700 °C
    0.17 °C
    0.07 °C
    0.06 °C
    0.08 °C
    0.25 °C
    0.10 °C
    0.09 °C
    0.10 °C
    0.64 °C
    0.27 °C
    0.21 °C
    0.21 °C
    1.42 °C
    0.61 °C
    0.46 °C
    0.45 °C
    B
    100 °C to
    1820 °C
    300 °C
    600 °C
    1200 °C
    1600 °C
    1.32 °C
    0.68 °C
    0.41 °C
    0.38 °C
    1.97 °C
    1.02 °C
    0.60 °C
    0.55 °C
    1.97 °C
    1.02 °C
    0.60 °C
    0.55 °C
    1.97 °C
    1.02 °C
    0.60 °C
    0.55 °C
    C
    0 °C to
    2315 °C
    600 °C
    1200 °C
    2000 °C
    0.23 °C
    0.28 °C
    0.44 °C
    0.33 °C
    0.40 °C
    0.60 °C
    0.37 °C
    0.45 °C
    0.66 °C
    0.54 °C
    0.63 °C
    0.91 °C
    D
    0 °C to
    2315 °C
    600 °C
    1200 °C
    2000 °C
    0.22 °C
    0.26 °C
    0.39 °C
    0.32 °C
    0.36 °C
    0.53 °C
    0.34 °C
    0.39 °C
    0.56 °C
    0.44 °C
    0.49 °C
    0.69 °C
    G
    0 °C to
    2315 °C
    600 °C
    1200 °C
    2000 °C
    0.24 °C
    0.22 °C
    0.33 °C
    0.36 °C
    0.32 °C
    0.46 °C
    0.36 °C
    0.32 °C
    0.46 °C
    0.36 °C
    0.33 °C
    0.46 °C
    L
    −200 °C to
    900 °C
    −200 °C
    0 °C
    800 °C
    0.13 °C
    0.08 °C
    0.09 °C
    0.19 °C
    0.12 °C
    0.12 °C
    0.45 °C
    0.28 °C
    0.23 °C
    0.99 °C
    0.62 °C
    0.48 °C
    M
    −50 °C to
    1410 °C
    0 °C
    500 °C
    1000 °C
    0.11 °C
    0.10 °C
    0.10 °C
    0.16 °C
    0.15 °C
    0.14 °C
    0.30 °C
    0.25 °C
    0.21 °C
    0.64 °C
    0.51 °C
    0.41 °C
    U
    −200 °C to
    600 °C
    −200 °C
    0 °C
    400 °C
    0.25 °C
    0.10 °C
    0.08 °C
    0.37 °C
    0.15 °C
    0.11 °C
    0.71 °C
    0.30 °C
    0.20 °C
    1.48 °C
    0.63 °C
    0.40 °C
    W
    0 °C to
    2315 °C
    600 °C
    1200 °C
    2000 °C
    0.24 °C
    0.22 °C
    0.33 °C
    0.36 °C
    0.32 °C
    0.46 °C
    0.36 °C
    0.32 °C
    0.46 °C
    0.36 °C
    0.33 °C
    0.46 °C
    Thermocouple Measurement Characteristics
    Range Temperature Display Resolution
    Slow / Medium
    Sample Rate
    Fast
    Sample Rate
    −270 °C to 2315 °C 0.01 °C 0.1 °C
    DC Voltage
    Maximum Input 50 V on any range
    Common Mode Rejection 140 dB at 50 Hz or 60 Hz (1 kΩ unbalance in LOW lead) ±50 V peak maximum
    Normal Mode Rejection 55 dB for power line frequency ±0.1 %, ±120 % of range peak maximum
    A/D Linearity 2 ppm of measurement + 1 ppm of range
    Input Bias Current 30 pA at 25 °C
    DC Voltage Accuracy
    Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for Channel 1, medium or slow sample rate. For channels x01 through x20 or when using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
    Range Accuracy Channel 1 Ch. x01 – x20 Fast Sample Rate T.C./ °C Outside
    18 °C to 28 °C
    ±100 mV 0.0037 % + 0.0035 % add 2 μ add 0.0008 % of range 0.0005 % + 0.0005 %
    ±1 V 0.0025 % + 0.0007 % add 2 μ add 0.0008 % of range 0.0005 % + 0.0001 %
    ±10 V 0.0024 % + 0.0005 % add 0.0008 % of range 0.0005 % + 0.0001 %
    ±50 V 0.0038 % + 0.0012 % add 0.0008 % of range 0.0005 % + 0.0001 %
    DC Voltage Input Characteristics
    Resolution Input Impedance
    Range Slow / Medium Fast
    ±100 mV 0.1 μ 1 μ 10 GΩ [1]
    ±1 V 1 μ 10 μ 10 GΩ [1]
    ±10 V 10 μ 100 μ 10 GΩ [1]
    ±50 V 100 μ 1 mV 10 MΩ ±1 %
    [1] - Input beyond ±12 V is clamped. The clamp current is up to 3 mA.
    DC Current
    Input Protection 0.15 A resettable PTC
    DC Current Accuracy
    Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for medium or slow sample rate. When using a fast sample rate, add the number given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the temperature coefficient numbers by the temperature deviation and add to the accuracy specification.
    Range Accuracy Fast Sample Rate T.C./ °C Outside
    18 °C to 28 °C
    ±100 μA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
    ±1 mA 0.015 % + 0.0011 % add 0.0008 % of range 0.002 % + 0.001 %
    ±10 mA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
    ±100 mA 0.015 % + 0.0035 % add 0.0008 % of range 0.002 % + 0.001 %
    DC Current Input Characteristics
    Resolution
    Range Slow / Medium Fast Burden Voltage
    ±100 μA 0.1 nA 1 nA <1 mV
    ±1 mA 1 nA 10 nA <1 mV
    ±10 mA 10 nA 100 nA <1 mV
    ±100 mA 100 nA 1 μA <1 mV
    Resistance
    Max. Lead Resistance (4-wire ohms) 10 Ω per lead for 100 Ω and 1 kΩ ranges. 1 kΩ per lead on all other ranges.
    Resistance Accuracy
    Accuracy is given as ± (% measurement + % of range). Basic accuracy specification is for 4-wire resistance, medium or slow sample rate. For 2-wire resistance add 0.02 Ω internal resistance if using Channel 1, or 1.5 Ω if using channels x01 through x20, and add external lead wire resistance. When using Fast sample rate, add the numbers given in the table to the accuracy specification. If the environment temperature is outside the specified range, multiply the Temperature Coefficient numbers by the temperature deviation and add to the accuracy specification
    Range Accuracy Fast Sample Rate T.C./ °C Outside
    18 °C to 28 °C
    100 Ω 0.004 % + 0.0035 % add 0.001 % of range[1] 0.0001 % + 0.0005 %
    1 kΩ 0.003 % + 0.001 % add 0.001 % of range[2] 0.0001 % + 0.0001 %
    10 kΩ 0.004 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
    100 kΩ 0.004 % + 0.001 % add 0.001 % of range 0.0001 % + 0.0001 %
    1 MΩ 0.004 % + 0.001 % add 0.006 % of reading plus 0.0008 % of range 0.0005 % + 0.0002 %
    10 MΩ 0.015 % + 0.001 % add 0.2 % of reading plus 0.0008 % of range 0.001 % + 0.0004 %
    100 MΩ 0.8 % + 0.01 % add 0.01 % of range 0.05 % + 0.002 %
    Notes:
    For conducted disturbances on mains input >1 V from 10 MHz to 40 MHz, add 0.6 % of range. For disturbances >3 V, accuracy is unspecified.

    [1] 0.15 % of range for 2-wire
    [2] 0.015 % of range for 2-wire
    Resistance Input Characteristics
    Range Resolution
    Slow / Medium
    Fast Source Current
    (open-circuit voltage)
    100 Ω 0.1 mΩ 1 mΩ 1 mA (4 V)
    1 kΩ 1 mΩ 10 mΩ 1 mA (4 V)
    10 kΩ 10 mΩ 100 mΩ 100 μA (6 V)
    100 kΩ 100 mΩ 1 Ω 100 μA (12 V)
    1 MΩ 1 Ω 10 Ω 10 μA (12 V)
    10 MΩ 10 Ω 100 Ω 1 μA (12 V)
    100 MΩ 100 Ω 1 kΩ 0.1 μA (12 V)
    Digital I/O
    Absolute Voltage Range –4 V to 30 V
    Input Minimum Logic High 2.0 V
    Input Maximum Logic Low 0.7 V
    Output Type open drain active low
    Output Logic Low (<1 mA) 0 V to 0.7 V
    Maximum Sink Current 50 mA
    Output Resistance 47 Ω
    Totalizer
    Absolute Voltage Range –4 V to 30 V
    Minimum Logic High 2.0 V
    Maximum Logic Low 0.7 V
    Minimum Pulse Width 50 μs
    Maximum Frequency 10 kHz
    Debounce Time 1.7 ms
    Maximum Count 1048575 (20 bits)
    Trigger
    Absolute Voltage Range –4 V to 30 V
    Minimum Logic High 2.0 V
    Maximum Logic Low 0.7 V
    Minimum Pulse Width 50 μs
    Maximum Latency 100 ms
    Alarm Output
    Absolute Voltage Range –4 V to 30 V
    Output Type open drain active low
    Output Logic Low (<1 mA) 0 V to 0.7 V
    Maximum Sink Current 50 mA
    Output Resistance 47 Ω
    1586-2588 DAQ-STAQ Input Module Specifications
    Maximum Input 50 V
    Offset Voltage <2 μV
    3-Wire Internal Resistance Mismatch <50 mΩ
    Basic CJC Accuracy 0.25 °C
    1586-2586 High-Capacity Input Module Specifications
    Maximum Input 50 V
    Offset Voltage <2 μV
    3-Wire Internal Resistance Mismatch <50 mΩ
    Basic CJC Accuracy 0.6 °C
    Quality Fluke 1586A Super-DAQ Precision Temperature Scanner F1586A for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: WUHU WANYI INDUSTRY CO.,LTD
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more FLUKE products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0