1. Equipment Overview
MyLab50 integrates advanced ultrasound technology and humanized
design, providing high-quality ultrasound images and accurate
diagnostic information for clinicians. It is suitable for multiple
examination areas such as abdomen, obstetrics and gynecology, small
organs, peripheral blood vessels, and rectal/cavity, providing
comprehensive diagnostic support for doctors.
2. Technical Features
High-frequency probe: MyLab50 is equipped with probes of various
frequencies, including/rectal dual-purpose probes (ultrasound
frequency 39MHz, scanning angle 200 degrees) and small organ
high-frequency probes (ultrasound frequency 413MHz). These probes
can meet the needs of different examination sites and provide clear
ultrasound images.
Intelligent image scanning technology: The device uses intelligent
image scanning technology, which can automatically adjust
parameters such as gain and scale, and act on 2D and Doppler
imaging, improving image clarity and diagnostic accuracy.
Pulse code group transmission and reception technology: MyLab50
uses pulse code group transmission and reception technology or
similar technology, which balances the transmission pulse frequency
according to different examination depths, improves penetration,
and makes the image of deep tissue clearer.
Fully digital ultrasound platform: The device uses a fully digital
multi-channel beamformer and variable aperture and dynamic
apodization technology, and the A/D conversion bit is 16bit,
ensuring high resolution and clarity of the image.
3. Application fields
MyLab50 is widely used in various clinical fields, including but
not limited to:
Abdominal examination: used to evaluate the morphology, structure
and function of abdominal organs such as the liver, spleen, and
kidneys.
Obstetrics and gynecology examination: used to evaluate the growth
and development of the fetus, the position and morphology of the
placenta, and the amount of amniotic fluid.
Small organ examination: Ultrasound examination of small organs
such as the thyroid and breast helps to find lesions such as
nodules and cysts.
Peripheral vascular examination: used to evaluate the morphology,
structure and hemodynamic status of blood vessels, and helps to
diagnose lesions such as vascular stenosis and aneurysms.
Rectal/cavity examination: suitable for ultrasound examination in
cavities such as the rectum and , which helps to find lesions such
as tumors and polyps.
4. Advantages and characteristics
High-definition images: MyLab50 uses advanced ultrasound technology
and high-resolution probes to provide clear ultrasound images,
which helps doctors make accurate diagnoses.
Easy to operate: The device adopts a humanized design, which is
easy to operate, reducing the difficulty and time cost of
operation.
Versatility: MyLab50 is suitable for multiple examination fields
and has broad application prospects and market demand.
Upgradability: The device supports software upgrades and modular
expansions, and can be customized and upgraded according to
clinical needs.
About the MyLab50 Control Panel
1. Control Panel Overview
The control panel of MyLab20 is the core part of the interaction
between the device and the user. It integrates a variety of
functions and setting options, allowing users to easily operate and
adjust the device's imaging parameters, image optimization methods,
and system settings.
2. Control Panel Layout
Monitor and host: The control panel is usually located below or on
the side of the monitor and connected to the host. The monitor is
used to display ultrasound images, while the control panel is used
to control and adjust these images.
Probe interface: There are usually one or more probe interfaces on
the control panel for connecting different types of ultrasound
probes (such as abdominal probes, high-frequency probes, etc.).
These probes are able to capture ultrasound images of different
parts and depths.
Control panel elements:
Trackball/mouse: used to move the cursor on the screen and select
menu options.
Keyboard area: Contains numeric keys, function keys, and
confirmation keys, etc., for entering data and executing commands.
Gain adjustment: used to adjust the gain of ultrasound images
(i.e., the brightness or contrast of the image).
Image optimization buttons: such as dynamic image storage, static
image storage, local zoom, color Doppler, pulsed Doppler, etc.,
used to optimize and save ultrasound images.
System Settings Button: Used to access the device's system settings
menu, such as time gain compensation, image resolution adjustment,
etc.
3. Operation Recommendations
Be familiar with the control panel: Before using MyLab20, it is
recommended that users first familiarize themselves with the layout
and functions of the control panel so that they can quickly find
the required functions and settings.
Adjust imaging parameters: According to the examination site and
imaging requirements, appropriately adjust imaging parameters such
as gain, depth, left and right double width to obtain the best
ultrasound image quality.
Optimize images: Use the image optimization buttons on the control
panel, such as dynamic image storage, static image storage, local
magnification, etc., to further optimize and save ultrasound
images.
Pay attention to safe operation: When operating MyLab20, please
follow the device's safe operating procedures to avoid unnecessary
damage or personal injury.
4. Precautions
Regular maintenance: Regularly maintain and service MyLab20 to
ensure the normal operation of the device and image quality.
Software update: Pay attention to the software update information
released by the manufacturer, and update the device's software
version in a timely manner to obtain better performance and
functions.
Training and education: For new users or users who are not
proficient in operation, it is recommended to receive professional
training and education to improve the quality and accuracy of
ultrasound imaging.
Other ultrasound parts related to Biosound that we can offer:
| Brand | Machine type | Description |
| Biosound | MyLab 25 | Power supply 9501083010/4271440192 |
| Biosound | MyLab 25 | Doppler PCB Board(P/N : 8607300660 / 8607300670) |
| Biosound | MyLab 40 | System disk |
| Biosound | MyLab 50 | TRX board 9501212000 |
| Biosound | MyLab 50 | P/N: 9501220000 |
| Biosound | MyLab 50 | User Interface Board 9102806000 |
| Biosound | MyLab 50 | SPS Switch Power Supply 9501100000 |
| Biosound | MyLab 50 | XVision Main board 18008-0000-99-2 Rev 1.2 |
| Biosound | MyLab 70 | ITR board 9501089000 |
| Biosound | Mylab twice | ITR board 9501089020 |
| Biosound | Mylab Series | CPU mainboard 9501361000 |
|