Sign In | Join Free | My burrillandco.com
Home > Textile Stock >

Corrtest Three Electrode Potentiostat CS350M Galvanostat And Potentiostat

    Buy cheap Corrtest Three Electrode Potentiostat CS350M Galvanostat And Potentiostat from wholesalers
     
    Buy cheap Corrtest Three Electrode Potentiostat CS350M Galvanostat And Potentiostat from wholesalers
    • Buy cheap Corrtest Three Electrode Potentiostat CS350M Galvanostat And Potentiostat from wholesalers

    Corrtest Three Electrode Potentiostat CS350M Galvanostat And Potentiostat

    Ask Lasest Price
    Brand Name : Corrtest
    Model Number : CS350M
    Certification : CE, ISO9001
    Price : Negotiable
    Payment Terms : T/T, D/P
    Supply Ability : 1000set/year
    Delivery Time : 5-10 working days
    • Product Details
    • Company Profile

    Corrtest Three Electrode Potentiostat CS350M Galvanostat And Potentiostat

    Three electrode potentiostat CS350M consists of DDS arbitrary function generator, high power potentiostat/galvanostat, dual-channel correlation analyzer, dual-channel high-speed 16bit/high-precision 24bit AD converter and extension interfaces. Max. current is ±2A, potential range is ±10V. EIS frequency range is 10uHz~1MHz. It can be used for various electrochemical fields such as corrosion, energy, material and electroanalysis. The current can be boosted up to 20A/40A with a current booster CS2020B/ CS2040B. Three electrode potentiostat CS350M cannot only measure the 3-electrode system, but also be applied for other configurations.


    What is three electrode system?

    The three electrode system consists of a working electrode, counter electrode, and reference electrode. The reference electrode's role is to act as a reference in measuring and controlling the working electrode potential, without passing any current. Most of the electrochemical tests are 3-electrodes system.

    Advantages of three electrode potentiostat CS350M


    Multi electrode system

    ● three electrode potentiostat CS350M supports 2-electrode, 3-electrode system, and 4-electrode system, can be used to test battery internal resistance or 4-electrode thin film impedance measurement

    ● With Zero resistance ammeter for galvanic current measurement

    Full floating

    All Corrtest potentiostats / galvanostats including three electrode potentiostat CS350M are designed as full-floating, and can be used for electrochemical study of working electrode connecting to earth, such as autoclave, metal part in bridge, concrete

    Real-time data storage

    Experiment data can be stored in real time. Even if the test is interrupted by a power failure, the data will be automatically saved.

    Electrochemical impedance spectroscopy(EIS)

    ● Three electrode potentiostat CS350M uses correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. The internal resistance of the instrument is up to 1013Ω. It's suitable for EIS measurements of high-impedance system (such as coating, concrete etc.)

    ● With constant current carrier and DC bias technology,three electrode potentiostat CS350M can be used for battery impedance measurement under charge and discharge state, suitable for ultra-low resistance system (such as 18650 battery, soft pack battery, battery core...)

    Software development kit(SDK)

    We can provide secondary development interfaces,API general interfaces and development examples, and can realize data call for Labview, C, C++, C#, VC and other program, which is convenient for secondary development and test methods customization.

    High current, high compliance options

    ●With the CS2020B/CS2040B booster, the current of three electrode potentiostat CS350M can be boosted to 20A/40A, which meets the requirement in fuel cell, power battery, electroplating, etc

    ●Can customize the instrument to be 30V high compliance voltage, which meets the test requirement in low-conductivity solutions (organic system, concrete system etc), especially suitable for carbon and nitrogen reduction study.


    Versatile data analysis

    CS Studio is the software for Corrtest potentiostat for experiment control and data analysis. It can do: multi-parameter Tafel curve fitting, derivation, integration and peak height analysis of voltammetric curve, EIS equivalent circuit customization and impedance spectrum fitting, etc.

    ● Multi-parameters Polarization curve

    ● EIS fitting

    ● Electrochemical noise analysis

    ● Pseudo capacitance calculation

    ● GCD specific capacitance, efficiency

    ● Mott-Schottky plot analysis

    ● CV analysis

    Combination test

    CS studio software supports the combination test for various experiments to achieve flexible and

    unattended test. You can set the parameters for each experiment in advance, and set the intervals, wait time etc between each experiment. The various experiments will run one by one as setting automatically.

    Combination Test: corrosion tests

    Combination Test: Pseudo capacitor tests


    Specifications of the three electrode potentiostat CS350M
    Support 2-, 3-electrode or 4-electrode systemPotential and current range: Automatic
    Potential control range: ±10VCurrent control range: ±2A
    Potential control accuracy: 0.1%×full range±1mVCurrent control accuracy: 0.1%×full range
    Potential resolution: 10μV (>100Hz),3μV (<10Hz)Current sensitivity:1pA
    Rise time: <1μs (<10mA), <10μs (<2A)Reference electrode input impedance:1012Ω||20pF
    Current range: 2nA~2A, 10 rangesCompliance voltage: ±21V
    Maximum current output: 2ACV and LSV scan rate: 0.001mV~10,000V/s
    CA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/ms
    Potential increment during scan: 0.076mV@1V/msSWV frequency: 0.001~100 kHz
    DPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHz
    DA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mV
    IMP frequency: 10μHz~1MHzLow-pass filters: covering 8-decade
    Operating System: Windows 10/11Interface: USB 2.0
    Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cm
    EIS (Electrochemical Impedance Spectroscopy)
    Signal generator
    Frequency range:10μHz~1MHzAC amplitude:1mV~2500mV
    DC Bias: -10~+10VOutput impedance: 50Ω
    Waveform: sine wave, triangular wave and square waveWave distortion: <1%
    Scanning mode: logarithmic/linear, increase/decrease
    Signal analyzer
    Integral time: minimum:10ms or the longest time of a cycleMaximum:106 cycles or 105s
    Measurement delay: 0~105s
    DC offset compensation
    Potential automatic compensation range: -10V~+10VCurrent compensation range: -1A~+1A
    Bandwidth: 8-decade frequency range, automatic and manual setting

    Techniques of three electrode potentiostat CS350M


    Techniques

    CS350M

    WITH EIS

    Stable
    polarization
    Open Circuit Potential (OCP)
    Potentiostatic (i-t curve)
    Galvanostatic
    Potentiodynamic(Tafel plot)
    Galvanodynamic
    Transient polarizationMulti-Potential Steps
    Multi-Current Steps
    Potential Stair-Step (VSTEP)
    Galvanic Stair-Step (ISTEP)
    Chrono
    methods
    Chronopotentiometry (CP)
    Chronoamperometry (CA)
    Chronocoulometry (CC)
    VoltammetryCyclic Voltammetry (CV)
    Linear Sweep Voltammetry (LSV)(i-v)
    Staircase Voltammetry (SCV) #
    Square wave voltammetry (SWV) #
    Differential Pulse Voltammetry (DPV)#
    Normal Pulse Voltammetry (NPV)#
    Differential Normal Pulse Voltammetry (DNPV)#
    AC voltammetry (ACV) #
    EISPotentiostatic EIS (Nyquist, Bode)
    Galvanostatic EIS
    Potentiostatic EIS (Optional freq.)
    Galvanostatic EIS(Optional freq.)
    Mott-Schottky
    Potentiostatic EIS vs. Time (Single freq.)
    Galvanostatic EIS vs. Time (Single freq.)
    Corrosion
    measurement
    Cyclic polarization curve (CPP)
    Linear polarization curve (LPR)
    Electrochemical Potentiokinetic Reactivation (EPR)
    Electrochemical Noise (EN)
    Zero resistance Ammeter (ZRA)
    Battery testBattery charge and discharge
    Galvanostatic charge and discharge (GCD)
    Potentiostatic Charging and Discharging(PCD)
    Potentiostatic Intermittent Titration Technique(PITT)
    Galvanostatic Intermittent Titration Technique(GITT)
    AmperometryDifferential Pulse Amperometry (DPA)
    Double Differential Pulse Amperometry (DDPA)
    Triple Pulse Amperometry (TPA)
    Integrated Pulse Amperometric Detection (IPAD)

    Q: Besides 3-electrode system, can the three electrode potentiostat CS350M

    also supports other configurations such as 2-electrode, and 4-electrode system?

    A: Yes. Three electrode potentiostat CS350M is a versatile and comprehension tool for all the electrochemical measurements.


    Q: What’s the difference between 2-electrode and 3-electrode system?

    A: In the two-electrode system, CE and RE are connected jointly to one electrode, while WE and SENSE are connected jointly to the opposite electrode, and then the entire potential is measured, including the potential at the interface between CE and electrolyte, and the potential of the electrolyte itself. Therefore, if the interface potential doesn’t have a critical effect on the entire study, a two-electrode system can be used. 2-electrode system is usually applied in energy storage or conversion, such as batteries, fuel cells, solar cells, etc. It’s also used to measure ultrafast kinetics of electrode processes or measure electrochemical impedance at high frequencies.

    The three-electrode system is the most commonly used setup in electrochemistry, in which current flows between CE and WE, the potential between WE and CE is controlled, and the potential is measured between RE and Sense.

    Q: Why do we use a three-electrode system for analytical electrochemistry?

    A: Electrochemical experiments are carried out in an electrochemical cell. The electrochemical cell works usually with a three electrode system, consisting of working electrode(WE), reference electrode(RE) and counter electrode(CE). The RE is used to monitor the potential of the working electrode. The most commonly used RE are the saturated calomel electrode and the silver/silver chloride electrode (Ag/AgCl). A good RE should have a constant potential with respect to time and temperature which should not be altered by passing a small current also. In this method, a constant potential is maintained on the working electrode by using the feed-back mechanism through the reference electrode. In three-electrode system, reference electrode offers very high resistance. For this reason for the current measurement, another electrode called auxiliary electrode or counter electrode is involved. It completes the cell circuit. Mostly the CE is an inert metal like platinum etc.

    The electrode in which modifications are performed by using various electrochemical techniques are called working electrode. In the electrochemical experiment, reaction of interest occurs at the surface of the working electrode. The WE is the main electrode where the potential is controlled and the current is measured. The use of a three-electrode potentiostat allows the potential at the working electrode and the current at the working electrode to be measured with little or no interference or contribution from the other electrodes.


    Quality Corrtest Three Electrode Potentiostat CS350M Galvanostat And Potentiostat for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Wuhan Corrtest Instruments Corp., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Single Channel Potentiostat products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0