    Ask Lasest Price
    Brand Name : Envsin
    Model Number : ESR4150
    Certification : CE ISO
    Price : Negotiation
    Payment Terms : L/C, T/T, Western Union
    Supply Ability : 25 per month
    Delivery Time : 30-35 days after receipt of payment
    • Product Details
    • Company Profile

    High Irradiance Testing Chambers Solar Panel Endurance Chambers with Xenon Arc Lamp

    Stainless Steel Solar Simulator Xenon Lamp Sunlight Simulation Chamber


    Application:
    Full-spectrum solar simulator can be used to evaluate equipment capacity exposure to the sun radiation under solar radiation heat or photochemical in hot season.The solar simulator can be used to evaluate the ability of equipment directly exposed to solar radiation in hot season to withstand the thermal effect or photochemical effect produced by solar radiation.The solar simulator can test the heat dissipation test samples and non-heat dissipation test samples. For the test of heat dissipation test sample, the heat dissipation power can not exceed the cooling capacity of the refrigeration system of the solar simulator, because the control of temperature and humidity is a dynamic balance process, in different temperature and humidity points, the cooling capacity of the refrigeration system is also accompanied by changes.
    Specifications:
    The Temperature Test:Temperature And Climatic Test:Solar Radiation Test:
    No radiation temperature range: -40℃~+120℃Temperature range:+20℃~+85℃UV Exposure Area: >5600cm²
    Radiation temperature range: -20℃~+100℃Humidity range: 10%RH~98%RH

    The light wavelength:

    All band spectrum, simulated sunlight from 280 nm to 3000 nm

    Temperature uniformity: ≤1.5℃

    Temperature uniformity: ≤1.5℃

    Irradiation intensity :

    (0 ~ 1200) W/M² can be adjusted, and can be recorded continuously during the test

    Temperature deviation: ±2.0℃Humidity uniformity: 3.0%RHN/A
    Temperature fluctuation: ±0.5℃Temperature deviation: ±2.0℃N/A
    Heating rate: ≥5℃/minHumidity deviation: +2/-3%RHN/A
    Cooling Rate: ≥2℃/minTemperature fluctuation: ±0.5℃N/A
    N/AHumidity fluctuation: ±2.0%RHN/A
    Performance Curve Diagram:

    Temperature And Humidity Curve Diagram

    • Temperature range:+20℃~+85℃
    • Humidity range:10%RH~98%RH
    • Temperature uniformity: ≤1.5℃
    • Humidity uniformity: 3.0%RH
    • Temperature deviation: ±2.0℃
    • Humidity deviation: +2/-3%RH
    • Temperature fluctuation: ±0.5℃
    • Humidity fluctuation: ±2.0%RH

    ​Standards:

    GJB150.7-86 Solar radiation test

    GJB150A.7-2009 Solar radiation test

    IEC60068-2-5 Test SA: Surface solar radiation simulation

    GB2423.24 Test SA: Simulate solar radiation on the ground

    DIN75220 Changes of automobile components in a sunlight simulator

    MIL-STD 810G Environmental engineering related matters and laboratory testing


    Temperature, Radiation Diagram:

    GB/T2423.24-1995 test procedure:

    • Test procedure A

    Take 24h as a cycle, irradiate for 8h, stop for 16h, repeat the test as required (the total radiation amount of each cycle is 8.96kw.h /㎡, equivalent to the most severe natural conditions).

    • Test procedure B

    Take 24h as a cycle, irradiation for 20h, stop for 4h, repeat the test as required (the total radiation amount of each cycle is 22.4kw.h /㎡).

    • Test procedure C

    Do continuous exposure as required.

    Quality High Irradiance Testing Chambers Solar Panel Endurance Chambers with Xenon Arc Lamp for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Envsin Instrument Equipment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Solar Simulation Chamber products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0