| Sign In | Join Free | My burrillandco.com |
|
| Ask Lasest Price | |
| Brand Name : | AI |
| Model Number : | AIC-2809 |
| Certification : | ISO |
| Price : | Negotiable |
| Payment Terms : | L/C, T/T, Western Union |
| Supply Ability : | 200 sets per month |
| Delivery Time : | 30 days |
Introduction
The test method of Cavitation Corrosion and Erosion-Corrosion Characteristics Analyzer is: pump the sample with a standard aluminum automobile water pump, run it for 100h under the conditions of 113 ºC, 103kpa and pump speed of 4600r / min, and then check the water pump to determine the degree of cavitation corrosion, and grade it according to the grading system table.
Characteristic
1. The Cavitation Corrosion and Erosion-Corrosion Characteristics
Analyzer is composed of operation and display, heating control,
speed control, pressure control, flow control system and supporting
components;
2. Motor: used for coolant circulation drive, linked with water
pump;
3. Water pump: the standard ASTM D method requires imported water
pump;
4. Vacuum pressure gauge: digital display of real-time pump inlet
vacuum;
5. Throttle valve: used to regulate the flow rate of water pump;
6. Heater: heat the coolant to the test temperature;
7. Liquid storage tank: stores cooling liquid for pipeline system;
8. Heat exchanger: provide 35 ~ 38 ºC test temperature through
cooling water heat exchange;
9. Regulating valve: three regulating valves are used to adjust
vacuum degree and test pressure;
10. Pressure gauge: displays the pressure during the test;
11. Expansion tank: steam expansion device
Technical specifications of ASTM D2809 Cavitation Corrosion and Erosion-Corrosion Characteristics Analyzer
| 1 | Applicable standards | ASTM D2809, SH/T0087 |
| 2 | Environmental requirements | 20 ºC ~ 25 ºC, humidity < 60% |
| 3 | Fuse | 20A |
| 4 | Pump speed | 0 ~ 4600 ± 100r / min |
| 5 | Temperature control range | < 650 ºC |
| 6 | Resolution (measurement) | 0.1 ºC |
| 7 | Temperature control accuracy | ± 0.1 ºC |
| 8 | Flow range | 0 ~ 20ml / min |
| 9 | Flow control accuracy | ± 5% |
| 10 | Power supply | AC220V 50Hz |
| 11 | Power consumption | 6.5KW |

|
| Company Info. |
| Advanced Instruments Co.,Limited |
| Verified Supplier |
| View Contact Details |
| Product List |