    Brand Name : XHA
    Model Number : XHA8015
    Certification : CE
    Price : negotiable
    Payment Terms : T/T, Western Union
    Supply Ability : 10000PCS/Month
    Delivery Time : 3 Working days
    • Product Details
    • Company Profile

    Conventional 2 Wire Photoelectric Smoke Detector For Fire Fighting Alarm System

    Conventional 2 Wire Photoelectric Smoke Detector For Fire Fighting Alarm System





    Introduction


    A conventional smoke detector is a safety device designed to sense the presence of smoke in the air and trigger an audible alarm to alert occupants of a potential fire. It typically consists of the following key components:


    Sensing Chamber:
    The sensing chamber is where the smoke detection mechanism is housed.
    It contains either photoelectric sensor, which is the core technology used to detect smoke.

    Alarm Horn/Sounder:
    When smoke is detected, the smoke detector activates a loud audible alarm, typically a high-decibel beeping or buzzing sound.
    The alarm is intended to wake up and alert occupants to the presence of smoke, prompting them to evacuate the area.


    Power Source:
    Conventional smoke detectors can be powered by a hardwired connection to the building's electrical system.

    Status Indicators:
    Smoke detectors often have visual status indicators, such as LED lights, to provide feedback on the device's operational status.
    These indicators can signal issues like low battery, sensor malfunctions, or normal operation.


    Mounting:
    Conventional smoke detectors are typically mounted on the ceiling or high on walls, as smoke typically rises and accumulates at the ceiling level.
    The mounting hardware allows for easy installation and replacement of the detector as needed.



    Parameters

    Product NameSmoke DetectorRated operational voltage9 to 28VDC Volts Non-polarized
    Adjustable Sensitivity1.06±.26%FTStatic current≤60µA @ 24 VDC
    Alarm current30mA @ 24 VDCWork temperature-10°C~+50°C
    CertificationCEHumidity≤95%.
    Size103*103*55mmWeight105 g

    Installation



    INSTALLATION
    NOTE: All wiring must conform to applicable local codes, ordinances, and regulations.
    NOTE: Verify that all detector bases are installed, that the initiating-device circuits have been tested, and that the wiring is correct.

    Remove power from initiating-device circuits before installing detectors.
    1. Wire the sensor base per the wiring diagram, Figure 1.
    2. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place.
    3. After all sensors have been installed, apply power to the control unit.
    4. Test the sensor(s) as described in the TESTING section of this manual.
    5. Notify the proper authorities that the system is in operation.

    Warning:Forbid connect 24VDC directly without current-limiting resistance. Otherwise, the detector would be burnt out.




    Product range

    Conventional Fire Alarm System
    Addressable fire alarm system
    Gas Extinguishing control system
    Beam Detector
    4 wire smoke detectors with relay output.
    2 wire Conventional smoke and heat detectors
    Explosion-proof flame detector for fire alarm system
    Standalone smoke detectors and combustable gas detector




    Service

    1. OEM &ODM service.
    2. Provide technical support and after-sale service.
    3. 1 year warranty.
    4. Normally 15 working days lead time.

    5. Welcome sample order.




    Quality Conventional 2 Wire Photoelectric Smoke Detector For Fire Fighting Alarm System for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Xinhe'an Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Conventional Fire Alarm System products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0