Sign In | Join Free | My burrillandco.com
Home > Telephones & Accessories >

Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface

    Buy cheap Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface from wholesalers
     
    Buy cheap Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface from wholesalers
    • Buy cheap Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface from wholesalers
    • Buy cheap Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface from wholesalers
    • Buy cheap Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface from wholesalers

    Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface

    Ask Lasest Price
    Brand Name : Olycom
    Model Number : OM3800-OLP
    Certification : CE RoHS FCC ISO9001
    Price : negotiable
    Payment Terms : T/T, PayPal
    Supply Ability : 1000 pairs/month
    Delivery Time : 5~10 working days
    • Product Details
    • Company Profile

    Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface

    Olycom OLP optical fiber line protection system


    Parameter


    ChassisStandalone 1U Chassis
    Operating temperature-5℃~+55℃
    Relative humidity5%~95% non-condensing
    Storage temperature-20℃~75℃
    Power supplyAC 220V/50~60Hz, DC(-36~-72)V dual power supply
    DimensionStandard 19' rack 1U (483*249*44mm)
    Max power consumption40W

    Front Panel



    Description


    1) Optical interface description: The flange on the equipment panel is the signal interface.

    2) When removing the optical fiber connection cable, cover it with a dust cap to prevent hard objects, dust or other dirt from touching, damaging and contaminating the optical output port.

    3) LCD display: displays input and output optical power and other related information.

    4) ▲——Up key; ▼——Down key; Enter——OK key; Esc——Cancel key.

    5) RST: Supports hardware reset and hardware initialization by operating buttons.


    Rear Panel



    Description


    1) The power supply (PIU) slot is on the back of the device, supporting AC (APU)/DC (DPU) optional, and 1+1 hot backup of the power supply.

    2) Indicator light: PWR: on: normal power supply; off: no power supply or abnormality.

    3) RJ45 Ethernet interface, RS-232 serial port: communication interface for device monitoring data information.


    Key Features


    1. Shorten communication interruption time, improve maintenance efficiency, and automatically restore communication in a very short time
    2. Reduce various losses caused by line failures
    3. Increase the reliability of the transmission network and improve the service quality of operators
    4. Arbitrary scheduling of active and backup work routes (line maintenance, cutover scheduling) while ensuring no business interruption
    5. Support screen display, real-time monitoring of main and backup optical fiber optical power, and transparent transmission
    6. Support remote and short-range control of the entire system to facilitate equipment management and maintenance.

    OLP: 1+1


    Diagram



    Specification


    FunctionSpecification
    Working wavelength range1260nm~1650nm
    OLP TypeOLP-1+1 (double transmission and selective reception)
    Switching time<15ms
    Introducing lossesWorking path<4dB
    Alternate path<1.2dB
    Monitor optical power range-50 dBm ~+25dBm
    Optical interfaceLC/UPC (Optional)
    Max power consumption5W
    MTBF>100,000 hours

    Interface definition


    InterfaceDescriptionFunction/Connection
    RxOLP local output interfaceConnect to local device RX port
    TxOLP local receiving interfaceConnect to the local device TX port
    R1Main route receiving interfaceConnect to peer T1
    T1Main route output interfaceConnect to peer R1
    R2Backup route receiving interfaceConnect to peer T2
    T2Backup route output interfaceConnect to peer R2

    Indicator definition


    InterfaceDescriptionFunction
    PWR1/PWR2OLP power indicator

    On, OLP power supply is normal

    Off, power supply failure

    RUNOLP system indicator

    On, the OLP is operating normally

    Off, there is an operating failure.

    ACKOLP instruction return indicator

    On, there is an instruction to return

    Off, there is no instruction to return.

    LOSOLP signal indicator

    On, the optical signal is lost

    Off, the signal is lost

    ALMOLP alarm indicatorNo optical signals or abnormal input and output
    AutoOLP working mode indicator

    On, working in automatic mode

    Off: working in manual mode

    R1OLP main route receiving indicator

    On, reception is normal

    Off, reception is abnormal

    R2OLP backup route receiving indicator

    On, reception is normal

    Off, reception is abnormal

    T1OLP main route output indicator

    On, the output is normal

    Off, the output is abnormal

    T2OLP backup route output indicator

    On, the output is normal

    Off, the output is abnormal

    PriMain route working indicatorOn, working on the main route

    Settings


    1.Working mode setting


    The device provides two working modes: manual mode and automatic mode.

    The manual mode is used for device commissioning and forced switching.

    (1) Select automatic and manual through network management;

    (2) Select through the device button, long press the device panel button until the Auto light goes out (working in manual) or lights up (working in automatic)

    After the operator completes the operation, the equipment should be placed in automatic working mode, otherwise protection failure accidents may occur.

    Note: The device supports automatically returning from manual mode to automatic mode, and the return time is 5 minutes by factory default setting.


    2.Main route settings


    The device provides main route settings. Customers can select R1 or R2 as the main route according to needs; the factory default is R1 as the main route


    3.Work route settings


    The factory default R1 is the primary working route (Pri), and R2 is the backup working route (Sec).

    When the device is in automatic working mode, the device will automatically select a working route based on line conditions:

    (1) When only one route is available: work on the channel corresponding to the available route;

    (2) When both routes are available: the route corresponding to the route that works first in time (if working on the backup channel, the device will automatically switch back to the main channel after 5 minutes, provided that the device is started the switchback function).

    When selecting a route manually, set the device to manual mode and set the working route through the panel buttons or network management


    4.Switch threshold power value setting


    The initial switching threshold power value of the device is -30dBm. The user can make corresponding settings according to the type of device and the actual situation of the other party's line.

    Basic principle: The switching threshold power value is slightly greater than the minimum received power value of the optical transmission equipment, and the difference is 0.5~1dB. (The minimum received power value is subject to ensuring normal transmission of the entire system service).


    5.Switchback mode settings


    Definition of switchback: In automatic mode, the device switches from the backup state to the main state. Can be set to "automatic switchback" or "automatic no switchback". In the "automatic non-switchback" mode, even if the switchback conditions are met (both the primary and backup routes are normal), the backup route will not be automatically switched to the main route.


    6.Switchback delay setting


    When the device is in the "automatic switchback" mode, the optical path is in the backup state, and the device is working in the automatic mode, the device will perform light detection on the main and backup paths in real time. If it detects that the optical power of the main and backup paths is within M time (0~999 minutes), the device will automatically switch back to the main road (Pri) state.


    Application



    Description


    OLP TX is connected to the TX light-emitting port of the customer equipment

    RX is connected to the RX light-receiving port of the customer equipment

    R1 is connected to the opposite OLP device T1 through the optical cable

    R2 is connected to the opposite OLP device T2

    T1 is connected to the opposite OLP device R1

    T2 is connected to the opposite end. OLP device R2 port


    Quality Fiber Optical Line Protection OLP Unit Standalone Type With LED Interface for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Olycom Technology Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more WDM Transmission System products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0