Sign In | Join Free | My burrillandco.com
Home > Professional Audio, Video & Lighting >

MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V

    Buy cheap MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V from wholesalers
     
    Buy cheap MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V from wholesalers
    • Buy cheap MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V from wholesalers
    • Buy cheap MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V from wholesalers
    • Buy cheap MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V from wholesalers
    • Buy cheap MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V from wholesalers

    MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V

    Ask Lasest Price
    Brand Name : Estel
    Model Number : MGA3000/E1
    Certification : CE UL FCC
    Price : USD200-USD1000
    Payment Terms : T/T, Western Union
    Supply Ability : 5000
    Delivery Time : 10 days
    • Product Details
    • Company Profile

    MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V

    MGA3000/E1 Outdoor Cabinet Air Conditioner Refrigeration Product Self-developed for Cabinet
    1.Introduction
    1.1. Preface
    This manual introduces the guide for the installation, operation, function and routine maintenance of
    the cabinet air conditioner. Please read carefully the manual before using and follow the usage and note.
    Note: All the operations of this product shall be performed by professional engineers.
    1.2. Product introduction
    The air conditioner is one kind of refrigeration product self-developed for cabinet. It is applicable in
    the place where the cabinet internal heat is very large, the internal electronic equipment is sensitive to the
    environment temperature and which should be isolated internally and externally completely. This product
    has multiple functions, high reliability, and has the feature that it can start to work without complex
    debugging after powering.
    The fan in the internal cycle air path absorbs the hot air from the upside to make air heat exchange
    by evaporator fins, and sends the cooled air from the downside of the air conditioner. By so, the air in
    cabinet can cycle to achieve the purpose of lowering the temperature. Meanwhile, The fan in the external
    cycle air path absorbs the external cold air from the downside, and discharges the hot air from the upside
    after heat exchange.
    2. Product parameter
    2.1. Product technology parameters
    ItemNameUnitParameter
    Dimension and installationBody outline dimension (widthheightdepth)mm784*619*245
    Outline dimension includingmm/
    flange (widthheightdepth)WeightKg40
    Installation methodFloor Mounted
    Installation methodOutdoor
    Environment and protectionWorking environment temperature°C-40 to +55
    NoisedB(A)65
    Life expectancyYears>10
    IP gradeIP55
    RefrigerantR134a
    ROHS certificationyes
    Input voltage range220±15%VAC/50Hz
    PerformanceRefrigerating capacity (L35/L35)W3000
    Rated Refrigerating input power (L35/L35)W1280
    Rated Refrigerant current (L35/L35)A5.8
    Maximum Refrigerating currentA8.5
    Heat capacity (optional)W1000
    Air volume of Inner CirculationM3/h900

    2.2. Installation diagram
    Note: the installation diagram is just for reference, the specific installation scheme should be
    determined according to the environment of the actual usage
    3. Preparation and installation
    3.1. Removing package and checking
    1. Please prepare installation tools: knife and scissors, and wear protective gloves.
    2. Please remove wrapping film and packing belt, then remove the carton, take out the air
    conditioner.
    3. Please check the attachment list and accessory bags in the carton, check whether the air
    conditioner model is right.
    Notes:
    1. After removing the outer package, please make sure that the air conditioner is placed
    upright , and not placed horizontally or upside down.
    2. After removing the outer package, please check carefully whether the appearance of the air
    conditioner is damaged or oil polluted, if the appearance of the air conditioner has obvious
    deformation or oil stain, please contact the manufacturer in time.
    3. If there is no need to install the product immediately or it needs to be transported to other
    place, please repack the air conditioner after the checking.
    4. It is recommended to recycle the unpacking materials.
    3.2. Mechanical installation
    Installation tool: Phillips screwdriver
    Installation Steps:
    1) Choose cut location on the cabinet according to the holing diagram, remove the shadow
    area and make the installation hole.
    2) Make air conditioner flange close to cabinet door, Fix the air conditioner on the installation
    surface of the cabinet firmly with M5 screws.
    3) Check whether air conditioner is installed levelly and firmly.
    Notes:
    1) Check whether air conditioner drainage loop is smooth, in case that drainage is blocked.
    2) When determine the location of the installation hole in the cabinet, you should avoid the inlet
    and outlet air ports inside the cabinet are not blocked by any components inside the cabinet, and
    the two should be kept a horizontal distance of more than 150mm; otherwise, it is prone to lead
    to r short circuit of the return air, and poor cooling effect, etc.;
    3) Carrying or moving the air conditioner should be careful to avoid colliding it and scratching
    its surface coating;
    3.3. Electrical installation
    (1) Power input port
    ItemPortDefinition
    LiveLPower input cable L
    NullNPower input cable N
    EarthPEEarth line

    (2) Alarm output and signal input port
    ItemPortDefinition
    + RS485 communication interfaceRS485ARS485 communication ports (+)
    - RS485 communication interfaceRS485BRS485 communication ports (-)
    The public alarm dry nod (NO)NOIt is normally open if no alarm
    The public alarm dry nod (COM)COMCommon port
    The public alarm dry nod (NC)NCIt is normally close if no alarm
    4. Product function
    4.1. Cooling
    When the temperature inside cabinet is higher than refrigeration starting temperature, it starts
    refrigerating; when the temperature inside cabinet is lower than refrigeration stopping temperature, it
    stops refrigerating.
    ParameterDefault valueSetting rangeUnitNote
    Refrigeration starting temperature32[20~40]°CRefrigeration stopping temperature = Refrigeration starting temperature - Refrigeration return difference
    Refrigeration return difference5[3~10]°C

    4.2. Heating(Optional)
    When the temperature inside cabinet is lower than heating starting temperature, it starts heating;
    when the temperature inside cabinet is higher than heating stopping temperature, it stops heating.
    ParameterDefault valueSetting rangeUnitNote
    Heating starting temperature5[-10~15]°CHeating stopping temperature = Heating starting temperature + Heating return difference
    Heating return difference10[3~15]°C

    4.3. Remote monitor
    Air conditioner has an RS485 communication interface, supporting MODBUS- RTU communication
    protocol.The air conditioner communicates with the upper monitor through the RS485 communication
    interface. Or users can check the air conditioner’s running state by viewing the display screen directly and
    change its running parameters.
    4.4. The control of external fan (Optional)
    According to the optional requirement, the external fan (Hydrogen discharge / emergency fan)19
    automatically realizes cycle hydrogen discharging and emergency ventilation function.
    Hydrogen discharge function(Optional):When hydrogen discharge cycle comes, air conditioner start
    the hydrogen discharge fan, the control switch closes.
    ParameterDefault valueSetting rangeUnit
    Cycle24[0~72]h
    Discharging time5[0~10]Min
    Emergency ventilation function (Optional): When the temperature inside cabinet is higher than
    Emergency ventilation starting temperature, emergency ventilation fans run; when the temperature inside
    cabinet is lower than Emergency ventilation stopping temperature, emergency ventilation fans stop.
    ParameterDefault valueSetting rangeUnit
    Starting temperature45[28~50]°C
    Stopping temperature42[25~50]°C

    5. Display screen
    5.1. Display interface
    NO.IconFunctionFunction explanation
    1❄️Refrigerating runningIndicate whether refrigerating runs or not
    2

    Quality MGA3000/E1 Outdoor Telecom Cabinet with 3000W AC Power Supply, IP55 Rating, 220V for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Tianjin Estel Electronic Science and Technology Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Outdoor Cabinet Air Conditioner products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0