Sign In | Join Free | My burrillandco.com
Home > Telecommunication Services >

INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks

    Buy cheap INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks from wholesalers
     
    Buy cheap INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks from wholesalers
    • Buy cheap INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks from wholesalers
    • Buy cheap INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks from wholesalers
    • Buy cheap INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks from wholesalers

    INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks

    Ask Lasest Price
    Brand Name : ITI-LINK
    Model Number : ITI-CT5SF-024
    Certification : UL, ETL, CSA, RCM, TUV, CPR, CE, RoHS
    Payment Terms : T/T
    Supply Ability : 2000pcs/day
    Delivery Time : 15-45Days
    • Product Details
    • Company Profile

    INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks

    INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks

    Product Description:

    1. Superior Electromagnetic Shielding

    The INTEGRITY Cat5e SFTP Cable is designed with dual shielding (aluminum foil and tinned copper braid) for exceptional EMI protection, providing up to 25dB noise resistance. Perfect for environments requiring high confidentiality and interference resistance.


    2. High-Quality Oxygen-Free Copper

    Featuring high-grade oxygen-free copper conductors, this network cable ensures stable and reliable electrical performance, greatly exceeding standard Cat5e specifications for optimal data transmission quality.


    3. Stable High-Speed Performance

    Supporting typical speeds of 100Mbps and 100MHz bandwidth over a 90-meter distance, this cable delivers fast and reliable connections for LAN networking and high-speed applications.


    4. Versatile & Secure Applications

    Ideal for use in high-security environments, this cable is perfect for shielded confidential systems, office networks, and any installation where EMI protection and data security are critical.


    5. Durable & Robust Construction

    Built to endure harsh environments, the SFTP cable features a durable construction that withstands physical stress while maintaining excellent transmission quality for indoor network wiring.


    6. Advanced Shielding Technology

    The unique 0.06mm aluminum foil and tinned copper braid shielding ensures up to 90dB EMI protection, making it suitable for installations in areas with extreme electromagnetic interference.


    7. Compliant with Industry Standards

    Exceeds the performance of traditional Cat5e cables, making it ideal for use in demanding industrial, commercial, and residential networking applications.


    Performance Index:

    Electrical Properties

    Conductor Resistance at 20°C

    NF EN 50289-1-2 / IEC 60189-1

    ≤ 9.5 Ω / 100m

    Resistance unbalance within a pair

    NF EN 50289-1-2/ IEC 60708

    2%

    Dielectric Strength

    Test Voltage (cd/cd): 1.00KV DC or 0.7 KV AC for 1 min Test Voltage (cd/screen): 1.00KV DC or 0.7 KV AC for 1 min

    NF EN 50289-1-3 / IEC 61196-1-105

    No breakdown

    Insulation Resistance at 20°C after 2min of electrification under a DC voltage between 100 & 500V

    NF EN 50289-1-4 / IEC 60885-1

    >1500 MΩ / 100m

    Mutual capacitance

    NF EN 50289-1-5 /IEC 60189-1

    5600pF / 100m MAX

    Capacitance unbalance pair to ground at 800Hz or 1 kHz

    NF EN 50289-1-5 / IEC 60189-1

    ≤ 160 pF / 100m

    Characteristic impedance at 100MHz

    NF EN 50289-1-11/ IEC 61156-1

    100 ± 15 Ω

    Spark Test

    UL444

    2000 ± 250VOC


    Transmission Properties

    CAT5e ANSI/TIA-568.2-D; IEC 61156-6; YD/T1019-2013

    No.

    Frequency

    Attenuation (Max)

    Propagation Delay

    (MAX)

    Propagation Delay Skew

    (MAX)

    Return Loss (Min)

    NEXT (Min)

    PS NEXT (Min)

    EL-FEXT (Min)

    PS EL-FEXT (Min)

    MHz

    dB/100m

    ns/100m

    ns/100m

    dB(on 100m)

    dB(on 100m)

    dB(on 100m)

    dB(on 100m)

    dB(on 100m)

    1

    4

    4.05

    552

    45

    23.01

    56.27

    53.27

    51.96

    48.96

    2

    8

    5.77

    546.73

    45

    24.52

    51.75

    48.75

    45.94

    42.94

    3

    10

    6.47

    545.38

    45

    25

    50.3

    47.3

    44

    41

    4

    16

    8.25

    543

    45

    25

    47.24

    44.24

    39.92

    36.92

    5

    20

    9.27

    542.05

    45

    25

    45.78

    42.78

    37.98

    34.98

    6

    25

    10.42

    541.2

    45

    24.32

    44.33

    41.33

    36.04

    33.04

    7

    31.25

    11.72

    540.44

    45

    23.64

    42.88

    39.88

    34.1

    31.1

    8

    50

    15.07

    539.09

    45

    22.21

    39.82

    36.82

    30.02

    27.02

    9

    62.5

    16.99

    538.55

    45

    21.54

    38.36

    35.36

    28.08

    25.08

    10

    100

    21.98

    537.6

    45

    20.11

    35.3

    32.3

    24

    21

    11

    12

    13

    14

    Remarks: are the reference values


    Notic:


    1, Wiring Planning and Design
    > Information point setting: Reasonably set information points according to actual needs. For example, the master bedroom can be equipped with two information points so that two people can operate the computer simultaneously; Other bedrooms and living rooms can be equipped with an information point; In the hidden areas of the middle and front and rear balconies of the residence, 2-3 information points can be set up to facilitate the installation of wireless network access devices in the future.
    > Location of information socket: When selecting the location of the information socket, ensure that it is convenient to use and not obstructed by furniture, while maintaining privacy. In the dormitory, information sockets can be placed on both sides of the bed; In the living room, one end of the sofa can be located near the window; In the study, it should be close to the desk, and the vertical distance between the information outlet and the floor should not be less than 20 centimeters.

    2, Network cable selection and connection
    > Network cable types: For indoor use, unshielded Category 5 cables are generally preferred.
    > Network cable connection method: It should follow the EIA/TIA 568B or EIA/TIA 568A standards. Direct lines are used for connecting network cards and switches, as well as optical transceiver modules and switches; Crossover cables are used for connecting network cards to each other and hubs to each other. When making network cables, they must be connected according to standard specifications to ensure the normal operation of the network.
    > Cable length and bending: When wiring, pay attention to the cable length and bending radius. The maximum transmission distance of Category 5e Ethernet cables is usually 100 meters, and exceeding this distance may cause signal attenuation. At the same time, under non heavy pressure conditions, the bending radius of the network cable should not be less than 8 times the diameter of the cable to ensure stable signal transmission.

    3, Gathering device and power supply settings
    > Location of the gathering device: The gathering device should be placed in a well ventilated and concealed place, avoiding installation in damp, water sensitive, and electromagnetic interference prone areas.
    > Power setting: The hub device requires power supply, so when decorating, it is necessary to reserve a power interface for the hub device.

    4, Interference and Protection
    > Electromagnetic interference: Twisted pair cables and computers should be kept at a distance from washing machines, refrigerators, air conditioners, fans, etc. to avoid affecting the signals in the twisted pair cables.

    5, Testing and Acceptance
    > Line testing: After the wiring is completed, professional testing instruments should be used to test the lines to ensure that the connectivity and transmission speed of each line meet the design requirements.
    > Acceptance criteria: During acceptance, relevant standards and specifications should be followed to ensure that the wiring quality meets the design requirements.
    Quality INTEGRITY Cat5e SFTP Cable Enhanced EMI Shielding For Secure Networks for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Integrity Cable Co., Limited
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more SFTP CAT5E Cable products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0