Sign In | Join Free | My burrillandco.com
Home >

3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified

    Buy cheap 3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified from wholesalers
     
    Buy cheap 3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified from wholesalers
    • Buy cheap 3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified from wholesalers
    • Buy cheap 3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified from wholesalers
    • Buy cheap 3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified from wholesalers
    • Buy cheap 3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified from wholesalers
    • Buy cheap 3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified from wholesalers

    3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified

    Ask Lasest Price
    Brand Name : WINLEY
    Model Number : ZGS-3750/35
    Certification : UL/cUL,CE,ISO
    Price : $5000-$150000
    Payment Terms : T/T
    Supply Ability : 1000set/month
    Delivery Time : 30days
    • Product Details
    • Company Profile

    3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified

    3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To 480Y ANSI IEEE DOE 2016 With UL/cUL Certified


    A padmount transformer is a ground-mounted utility distribution transformer, which usually is housed in a locked metal cabinet,situated on a small concrete pad. They are usually manufactured in power ratings from around 75 to around 5000 kVa and often includes built-in fuses and switches. A typical enclosure includes a tank for holding the core/coil assembly of the padmounted transformer immersed in oil or the like, and a wiring cabinet having high and low voltage wiring compartments for enclosing the high and low voltage bushings, respectively, of the transformer, etc.



    Why choose us


    • WINLEY produces a full range of three phase pad mounted transformers with a capacity of 45kva-5500KVA and a voltage of up to 34.5KV. The products meet or even exceed the standards of DOE 2016, IEEE/ANSI, CSA, IEC, NEMA, etc.
    • The three phase pad mounted transformer produced by WINLEY has obtained UL/cUL certification (Certificate Number: UL-US-2431836-0, UL-CA-2423202-0), and can apply for UL (partner authorization) according to customer requirements.
    • Our products are exported to North America, South America, the Philippines and other places in large quantities. We have rich experience in design and production, professional and reliable after-sales service, and can deliver goods quickly within 7-35 days.


    Three Phse Pad Mounted Transformer Main data


    Transformer TypePad Mounted, Compartmental-Type
    Transformer Feed TypeLoop Feed
    OperationStep-Down
    PhaseThree Phase
    Capacity3.75 MVA (3750 KVA)
    Vector GroupDYN1
    Primary Voltage34500V
    Secondary Voltage480Y/277
    Frequency60 Hz
    Temperature Rise65°C
    Insulation RatingClass E Insulation - 120°C, 248°F
    Cooling ClassKNAN; Self-Cooled
    Impedance (Typical)5.75%
    Efficiency Standard(s)Meets DOE 2016 Standards, Meets ANSI/IEEE Standards
    K-Factor Rating (Harmonic Mitigation)K-1 (Standard)
    Winding MaterialCopper
    Ambient Temperature Rating40°C

    Technical drawings



    Product Structure


    • 60 Hz operation.
    • 65°C average winding rise.
    • Radial & loop feed arrangements.
    • Dead and live front type of HV terminals.
    • HV BIL 45 – 150 kV (Dead Front) 200 kV (Live Front).
    • LV BIL 30 – 60 kV.
    • Three-point latching of low-voltage door.
    • High-voltage door, which can be opened only after the low-voltage door is opened.
    • Rigid steel partition.
    • Transformer tank welded from cover to base.
    • Permanent nameplate.
    • One-inch NPT pipe cap filling provision.
    • ANSI tank ground pads.
    • One-inch drain valve and sampler.
    • Automatic pressure-relief valve (35 SCFM).
    • Tap changer with (2) 2.5% full capacity taps above and below nominal.
    • One 10”x18” (or 14”x25”) hand hole in transformer tank cover.
    • Painted olive-green color (Munsell 7GY 3.29/1.5).
    • Designed, manufactured and tested in accordance with the latest ANSI standards



    Factory Tests


    • Winding Resistance Test
    • Insulation Resistance Test
    • Voltage Ratio Error Test
    • Short-circuit Impedance Test
    • No-load Loss (Wattage) Test
    • Load Loss (Wattage) Test
    • Induced Voltage Withstand Test
    • Separate Source Voltage Withstand Test
    • Pressure Integrity Test Test

    Specification


    Rated Power
    (KVA)
    High Voltage
    (KV)
    Low Voltage
    (V)
    No-load Loss
    (W)
    On-load Loss
    (W)
    Height
    (mm)
    Depth
    (mm)
    Width
    (mm)
    Weight
    (kg)
    Weight
    (Lbs)
    75KVA34.5KV
    4.160KV
    12.47KV
    13.2KV
    13.8KV
    24940GrdY/14400
    1247Grdy/7200
    4160GrdY/2400
    or others
    277V
    347V
    480V
    600V
    120/240V
    208GrdY/120
    415GrdY/240
    480GrdY/277
    600Y/347
    1801250143091019306451422
    150KVA2802200153098015109892180
    300KVA480365016801080166014153119
    500KVA680510017901160181019054200
    750KVA980750020301300203027556074
    1000KVA11501030018541549165132357132
    1500KVA164014500215015702210583512864
    2000KVA216020645222016002380643014175
    2500KVA268023786233016503070886519544
    3000KVA3300303002460185032601130024912
    3735KVA4125378752680206040801440031746

    Production process



    FAQ


    1. Q: Can I have a sample order?

    A: Yes, we welcome sample order to test and check quality.

    2. Q: What is the lead time?

    A: Mass production time 15-25 days.

    3. Q: How long is the warranty?

    A: 24 monthes from B/L. If there are any accessory problems,just provide the photos of damaged accessory,then we will provide free service. According to the number of products,we will provide easily damaged accessories for free. we also can provide technical support if you need.

    4. Q: Is OEM/ODM available?

    A: Yes,it is! We are manufacturer with our own R&D team, we can customize products according to customer's drawing or requirements.

    Customized services:

    a. Customized color and special function.

    b. Customized box.

    c. Print customer's logo.

    d. Your other ideas about product, we can help you design and put them into production. The above customized services must be confirmed before production.

    5. Q: How to control the products quality?

    A: Our company owns the core technology ,all kinds of products hold CE certificate. We have professional engineers. Workers are strictly required to make products according to the drawings. Each process has technical instructors.The QC supervisors will regularly inspect the production. We will do products performance tests during production, and comprehensive quality tests when the products is completed.

    Quality 3 Phase Pad Mounted Transformer Distribution Power Oil Immersed 3750Kva Step-Down 34500V To  480Y ANSI IEEE DOE 2016 UL Certified for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Xiamen Winley Electric Co.,Ltd
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Three Phase Pad Mounted Transformer products from this supplier
    Inquiry Cart 0