Sign In | Join Free | My burrillandco.com
Home >

Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable

    Buy cheap Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable from wholesalers
     
    Buy cheap Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable from wholesalers
    • Buy cheap Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable from wholesalers
    • Buy cheap Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable from wholesalers
    • Buy cheap Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable from wholesalers
    • Buy cheap Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable from wholesalers

    Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable

    Ask Lasest Price
    Brand Name : QINGDAO YICABLE CABLE
    Model Number :
    Certification : KEMA,ISO,CE,IEC,PICC
    Price : US$1.0~300per meter
    Delivery Time : Negotiable
    • Product Details
    • Company Profile

    Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable

    Fire-Resistant Assemblies XLPE Insulation Frc LSOH 0.6/1kV Power Cable


    Construction:


    Stranded (RM) bare copper as per IEC60228
    Mica Tape for Fire-Proof
    XLPE (cross-linked polyethylene) Insulation
    Fillers strip, Yarn, or Paper
    Non woven Wrapping tape or Flame Retardant

    Extruded PVC Inner Covering

    Galvanized Steel Tape Armoured
    Overall Sheath: polyvinylchloride (PVC) or FR-PVC, PE, LSOH


    Application:


    Used for tall building, Hospital, Theatre, Power station, Metro Tunnel or Petrochemical Industry or other special place required for low smoke , zero halogen clean and safe cable.


    Technical data:


    Test voltage 0.6/1 kV [kV] 3.5 / 5 min.
    Temperature range in motion -5°C till +70°C
    fixed -20°C till +70°C
    Operating temperature short circuit °C 250
    Short circuit time max. [sec] 5
    Bending radius min. x diameter 15
    Flammability standard EN 60332-1-2

    Cross section of conductorThickness of insulationThickness of SheathApprox.cable diameterMax.resistance of conductor at 20 ℃Test Voltage(AC)
    mm2mmmmmmohm/kmKV/5min
    5x2.50.81.813.67.413.5
    5x41.01.816.14.613.5
    5x61.01.817.73.083.5
    5x101.01.821.01.833.5
    5x161.01.823.81.153.5
    5x251.21.828.70.733.5
    5x351.21.932.00.5243.5
    5x501.42.137.40.3873.5
    5x701.42.241.70.2683.5
    5x951.62.448.10.1933.5
    5x1201.62.553.00.1533.5
    5x1501.82.758.60.1243.5
    5x1852.02.965.10.09913.5
    5x2402.23.172.10.07543.5
    5x3002.43.480.10.0603.5
    5x4002.63.687.00.04703.5


    Main Properties


    No.Test ItemProperty
    1ConstructionListed to the tables
    2Conductor resistanceListed to the tables
    3Test VoltageA.C 3.5kV 5minNo breaken
    4Machenical Properties before agingTensile StrengthInsulationMin. 12.5N/mm2
    SheathMin. 12.5N/mm2
    Elongation at breakInsulationMin. 150%
    SheathMin. 150%
    Machenical properties after agingTensile StrengthInsulation100℃±2℃7days Min. 12.5N/mm2
    Sheath100℃±2℃7days Min. 12.5N/mm2
    Varying valve of tensile strengthInsulation100℃±2℃7days Max. 25%
    Sheath100℃±2℃7days Max. 25%
    Elongation at breakInsulation100℃±2℃7days Min.150%
    Sheath100℃±2℃7days Min.150%
    Varying valve of tensile strengthInsulation100℃±2℃7days Max. 25%
    Sheath100℃±2℃7days Max. 25%
    5Flame retardant propertyIEC60332 - 3
    6Constant of insulation resistivityMin at 20℃36.7
    Ki MΩ.kmMin at 70℃0.037


    Standards:


    IEC 60502, 60332, 60331

    DIN VDE 0276-620
    HD 620 S1: 1996
    DIN EN 60228 class 2 (construction)


    Packing and shipping: We are capable of meeting the most strict delivery schedules according to per purchase order. Meeting the deadline is always the top priority as any delay in the delivery of cable can contribute to overall project delay and cost overrun.
    Cable is supplied in wooden reels, corrugated boxes and coils. Cable ends are sealed with BOPP self adhesive tape and non-hygroscopic sealing caps to protect the cable ends from moisture. The required marking shall be printed with a weather-proof material on the outsides of drum according to customer's requirement.

    Product Tags:

    fire rated cable

      

    fire resistant wire

      
    Quality Flexible / Stranded Fire Resistant Cable XLPE Insulation Frc LSOH 0.6/1 kV Power Cable for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Qingdao Yilan Cable Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Fire Resistant Cable products from this supplier
    Inquiry Cart 0