Sign In | Join Free | My burrillandco.com
Home > Electronics Stocks >

Professional Gas Sensor for Respiratory Anesthesia Machines 8410185

    Buy cheap Professional Gas Sensor for Respiratory Anesthesia Machines 8410185 from wholesalers
     
    Buy cheap Professional Gas Sensor for Respiratory Anesthesia Machines 8410185 from wholesalers
    • Buy cheap Professional Gas Sensor for Respiratory Anesthesia Machines 8410185 from wholesalers

    Professional Gas Sensor for Respiratory Anesthesia Machines 8410185

    Ask Lasest Price
    Model Number : 8410185
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Supply Ability : 5000pcs
    Delivery Time : 5-8 work days
    • Product Details
    • Company Profile

    Professional Gas Sensor for Respiratory Anesthesia Machines 8410185


    8410185 Sensors For Respiratory Anesthesia Machines Gas Sensor


    Basic Information:

    • Brand: Drager
    • Model: 8410185
    • Product Type: Sensor for breathing anesthesia machines (specifically may be an oxygen sensor or flow sensor, subject to confirmation based on the equipment model)
    • Applicable Equipment: Compatible with Drager series breathing anesthesia machines (such as Fabius, Primus, etc.)
    • Origin: Germany (headquarters of Drager, with some components possibly produced in other countries)

    Technical Parameters:

    • Measurement Range:
      • If it is an oxygen sensor, the measurement range is usually 0%–100% O₂;
      • If it is a flow sensor, the measurement range shall be determined according to the specific model, generally covering the clinically commonly used respiratory flow range (e.g., 0–150L/min).
    • Accuracy:
      • The accuracy of the oxygen sensor is usually ≤±2% FS (full scale);
      • The accuracy of the flow sensor is ≤±3% of the reading or ±0.5L/min (taking the larger value).
    • Response Time:
      • Oxygen sensor: T90 (reaching 90% response) ≤10 seconds;
      • Flow sensor: response time ≤50ms when the airflow changes.
    • Operating Temperature: 5°C–40°C (in line with the environmental requirements of medical equipment)
    • Interface Type: Dedicated plug-in interface, compatible with the mainboard or module of Drager equipment
    • Power Supply Mode: Internal power supply of the equipment (usually DC 5V or 12V)

    Product Features:

    • High Accuracy: Adopts electrochemical or thermal measurement principles to ensure stable and reliable data, meeting the high-precision requirements of clinical anesthesia for gas concentration and flow.
    • Anti-interference: The sensor design has the ability to resist water vapor and corrosion, reducing errors caused by anesthetic gases, moisture, and other factors in clinical use.
    • Easy Maintenance: Supports hot-swap replacement without shutdown calibration, and some models have an automatic calibration function (such as zero and span calibration for oxygen sensors).
    • Safety Certification: Complies with medical equipment certification standards such as CE and ISO 13485, and has passed biocompatibility tests to ensure patient safety.

    Application Scenarios:

    • Breathing Anesthesia Machines: Used for real-time monitoring of parameters such as oxygen concentration and respiratory flow in the inhaled/exhaled gas of patients, providing data support for anesthetic depth control and ventilation management.
    • Intensive Care Equipment: Some models can be compatible with intensive care ventilators to assist in monitoring gas parameters during mechanical ventilation.

    Installation and Maintenance:

    • Installation Method: Directly insert into the sensor slot of the equipment, fix it with a buckle or screw, and use it after completing calibration according to the instructions.
    • Replacement Cycle:
      • Oxygen sensor: It is generally recommended to replace it every 1–2 years (affected by usage frequency and environment);
      • Flow sensor: There is no clear replacement cycle. If the measurement deviation exceeds the range or a fault code appears, it needs to be replaced in a timely manner.
    • Calibration Requirements: Standard gases (such as 21% O₂, 100% O₂) are required for calibration when installing for the first time or regularly (such as every 6 months).

    Precautions:

    • No Disassembly: The interior of the sensor is a precision component. Disassembly by non-professionals may cause damage or measurement failure.
    • Storage Conditions: Store in a dry environment without corrosive gases, at a temperature of 0°C–30°C and a humidity of ≤80%RH.
    • Compatibility: Only applicable to the specified models of Drager equipment. Do not mix it with equipment of other brands.

    Packaging and Certifications:

    • Packaging: Independent anti-static packaging, including instructions and a calibration certificate.
    • Certifications: International medical certifications such as CE, ISO 13485, and FDA (if applicable).


    ParameterDetails
    BrandDrager
    Model8410185
    Product Type

    Sensor for breathing anesthesia machines (possibly oxygen/flow

    sensor, subject to equipment model)

    Applicable EquipmentDrager Fabius, Primus series anesthesia machines
    OriginGermany
    Measurement Range- Oxygen sensor: 0%–100% O₂
    - Flow sensor: 0–150L/min (typical clinical range)
    Accuracy- Oxygen sensor: ≤±2% FS
    - Flow sensor: ≤±3% of reading or ±0.5L/min (whichever is larger)
    Response Time- Oxygen sensor: T90 ≤10s
    - Flow sensor: ≤50ms (to airflow changes)
    Operating Temperature5°C–40°C
    Interface TypeDedicated plug-in interface for Drager equipment
    Power SupplyInternal DC power (5V/12V)
    MaterialCorrosion-resistant sensor element with anti-moisture design
    Calibration Requirement

    Standard gas calibration (21% O₂, 100% O₂) required

    for first installation and every 6 months

    Replacement Cycle- Oxygen sensor: 1–2 years (usage-dependent)
    - Flow sensor: As needed (when deviation exceeds range)
    Safety CertificationCE, ISO 13485, FDA (if applicable)
    PackagingAnti-static independent package with calibration certificate
    Storage Conditions0°C–30°C, ≤80% RH, dry environment
    CompatibilityExclusive for Drager specified anesthesia machine models

    Quality Professional Gas Sensor for Respiratory Anesthesia Machines 8410185 for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: ShenzhenYijiajie Electronic Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Gas Sensor products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0