Sign In | Join Free | My burrillandco.com
Home > Valve Parts >

110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter

    Buy cheap 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter from wholesalers
     
    Buy cheap 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter from wholesalers
    • Buy cheap 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter from wholesalers

    110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter

    Ask Lasest Price
    Brand Name : ZJNF
    Model Number : ZJNF-1
    Certification : CE
    Price : negotiate
    Payment Terms : tt lc PayPal credit card
    Delivery Time : 18 days
    • Product Details
    • Company Profile

    110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter

    Here is the professional English translation of the layered ultra-clean workbench description:


    Laminar Flow Clean Bench
    A laminar flow clean bench utilizes a high-efficiency air filtration system to generate unidirectional airflow (vertical or horizontal), creating a localized high-cleanliness operating environment. Its core function is to protect samples from contamination. Key features and applications are as follows:

    I. Core Principles & Structure

    1. Laminar Flow Mechanism
      Room air is pre-purified by a primary filter, pressurized into a plenum chamber via a blower, and then filtered through a HEPA filter to form stable unidirectional airflow (vertical or horizontal)
      • Vertical Laminar Flow‌: Top-down airflow prevents direct exposure to operators; ideal for high-risk biomedical applications
      • Horizontal Laminar Flow‌: Horizontal outward airflow offers larger workspace; commonly used in electronics
    2. Cleanliness Class
      Work zone achieves Class 100 (ISO Class 5) cleanliness: ≤3.52 particles (≥0.5μm) per liter
    3. Core Components
      Include primary/HEPA filters, blower, stainless steel work surface, UV germicidal lamp, and smart control system (e.g., touchscreen for wind speed adjustment)

    II. Classification & Selection

    Classification BasisTypeCharacteristics
    Airflow DirectionVertical Laminar FlowTop-down airflow; high operator safety; suitable for biological labs
    Horizontal Laminar FlowLarger workspace; lower noise; preferred in electronics
    Operation StructureSingle-person single-sideSingle blower; lower noise
    Dual-person single-sideDual blowers; moderate noise increase
    Dual-person dual-sideEnables collaboration; requires larger space
    Special DesignsRecirculating TypeNo external ducts; flexible deployment in non-clean areas
    Benchtop TypeSpace-saving; ideal for compact labs

    III. Primary Applications

    • Biomedicine‌: Cell culture, vaccine preparation, aseptic preparation filling (contamination rate <0.8%)
    • Medical Testing‌: Virus isolation, nucleic acid detection (prevents aerosol contamination)
    • Precision Manufacturing‌: Electronic component assembly, optical instrument production (anti-dust/anti-static)
    • Food & Research‌: Microbial testing, gene editing (e.g., CRISPR), ensures experimental accuracy

    IV. Operation & Maintenance Guidelines

    1. Environmental Requirements
      Temperature: 5–35°C; humidity ≤85%; avoid dusty/explosive environments
    2. Safe Operation
      • Sterilize with UV light for 30 mins before use; keep glass sash partially closed during operation
      • Regularly monitor wind speed (0.3–0.6m/s for vertical flow) and filter pressure differential
    3. Maintenance Cycle
      • Clean primary filter monthly; replace HEPA filter every 2–3 years (varies by environment)
      • Equipment lifespan correlates with air cleanliness; shorter intervals in tropical regions

    V. Technology Evolution

    Modern models (e.g., VD-650) feature smart controls for stepless wind speed adjustment and real-time pressure display; DC motors reduce energy consumption by 30%, while stainless steel enhances corrosion resistance. High-end units include dynamic airflow monitoring to limit speed fluctuations to ≤20%


    Technical Data


    MODELZJNF-1ZJNF-2ZJNF-3ZJNF-4
    Table Size(mm)1200*600*7401200*600*1500600*600*7401800*600*1460
    Fan Size(mm)1200*600*7401175*575*320575*575*3201175*575*320
    MaterialAluminum / Stainless Steel
    Efficiency99.99% @ 0.3um

    Product Details


    Quality 110V/220V 50HZ/60HZ Mushroom Horizontal Current Laminar Flow Clean Workbench Made of Acrylic Plate with HEPA Filter for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: Shenzhen Zhong Jian South Environment Co., Ltd.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Laminar Clean Bench products from this supplier
    Find Similar Products By Category:
    Inquiry Cart 0