| Sign In | Join Free | My burrillandco.com | 
 | 
| Ask Lasest Price | |
| Brand Name : | RESUN | 
| Model Number : | R-6K-TH | 
| Price : | Negotiable | 
| Payment Terms : | T/T | 
| Supply Ability : | 10000 | 
| Delivery Time : | 3-30days | 
• Real time digital monitoring, operation data such as current, and
clear status at a glance. 
• Intelligent fault diagnosis, remote control mode switching, and
more convenient management. 
• Adapt to three-phase power systems and stably output high-power
electricity.
| Model | R-6K-TH | 
| PV input data | |
| Max. PV input power (kW) | 9 | 
| Max. PV input voltage (V) | 1000 | 
| Min. PV input voltage (V) | 125 | 
| Start-up voltage (V) | 125 | 
| MPPT voltage range (V) | 180~850 | 
| MPPT voltage range@full-load (V) | 250~850 | 
| Rated PV input voltage (V) | 600 | 
| No. of MPPT trackers | 2 | 
| No. of strings per MPPT tracker | 1/1 | 
| Max. input current per MPPT (A) | 18/18 | 
| Max. short-circuit current per MPPT (A) | 25/25 | 
| >> >>>  >>>  >Battery input data | |
| Battery type | Lithium-ion / Lead-acid | 
| Max. charge / discharge power (kW) | 6.6 | 
| Battery voltage range (V) | 150-550 | 
| Battery voltage range@full-load (V) | 180-550 | 
| Max. charging / discharging current (A) | 50/50 | 
| Rated charge / discharge current (A) | 40/40 | 
| Battery charging strategy | Self-adaption to BMS | 
| BMS communication | CAN | 
| AC output data (grid side) | |
| Rated output power (kW) | 6 | 
| Max. apparent output power (kVA) | 6.6 | 
| Max. apparent input power(kVA) | 13.2 | 
| Rated grid voltage (V) | 220 / 380; 230 / 400 | 
| Grid voltage range (V) | 187~264.5 | 
| Grid input voltage (V) | 380; 400 | 
| Rated grid frequency (Hz) | 50/60 | 
| Grid frequency range(Hz) | 45-55 / 55-65 | 
| Rated output current (A) | 8.7 | 
| Max. AC output current (A) | 9.5 | 
| Power factor | >0.99 (0.8 leading ~ 0.8 lagging) | 
| THDi | <3% | 
| Grid type | 3L+N+PE | 
| AC output data (back-up) | |
| Rated output power (kW) | 6 | 
| Max. apparent output power (kVA) | 6.6 | 
| Rated output voltage (V) | 220 / 380; 230 / 400 | 
| Rated output frequency (Hz) | 50/60 | 
| Rated output current (A) | 8.7 | 
| Max. AC output current (A) | 9.5 | 
| Peak output power | ≥110%, 10mins; ≥120%, 1.25min; ≥150%, 20ms | 
| Back-up switch time (ms) | <10 | 
| THDu | <2% | 
| Protection | |
| Supported protection | PV reverse polarity protection, Anti-islanding protection, Ground
fault protection, Battery reverse protection, Leakage current protection, Insulation resistance detection, Backup output short circuit protection, AC under-voltage protection, AC output over-current protection, AC over-voltage protection | 
| Over voltage category | DC Type II / AC Type III | 
| Certifications and standards | |
| Certificates | IEC 61000-6-1/-2/-3/-4, IEC 61000-3-11, IEC61000-3-12; EN 62109-1,
EN 62109-2; EN50549-1; EN50549-10; EN50438; G98/G99:2022; VDE-AR-N 4105:2018; CEI 0-21:2022; C10/11; Rfg:2016/NC Rfg:2018/PTPiREE:2021; NRS 097-2-1:2017; Hungary; NTS V2.1:2021-07&UNE217002:2020&UNE217001:2020; NA/EEA-NE7 – CH 2020; OVE Directive R 25:2020, TOR Erzeuger Type A V1.2; TR3.3.1:2019;ANRE228; ANRE228; NA/EEA-NE7; PPDS:2022 for A1&A2; RS 097-2-1 :2017; OVE Directive R 25:2020, TOR Erzeuger Type A V1.2; EIFS 2018:2 | 
| General data | |
| Ingress protection | IP65 | 
| Operating temperature range (℃) | -25~+60 | 
| Cooling | Natural cooling | 
| Relative humidity | 0-95% | 
| Operating altitude (m) | 4000(>2000 power derating) | 
| Dimensions W*D*H (mm) | 566 x 593.5 x 219.5 | 
| Weight (kg) | 32 | 
| Topology (solar / battery) | Transformerless / Transformerless | 
| Noise emission (dB) | <45 | 
| Display and communication | |
| Display | Monochrome screen | 
| Communication | RS485,CAN,WiFi | 
|   | 
| Company Info. | 
| RESUN ENERGY CO,.LTD | 
| Verified Supplier | 
| View Contact Details | 