The IK Pendulum Impact Testing Machine is an impact testing device for materials such as shells or glass. Pego make the device according to the requirements of IEC60068-2-75, GB/T2423.55, IEC62262, and GB/T20138 standards. It is mainly used for impact testing of non-metallic material specimens or products such as plastics, glass, and ceramics. It is a test instrument for evaluating the impact resistance of materials. According to the IK impact standards IEC62262 and GB/T20138, this test machine only contains five impact elements: IK07, IK08, IK09, IK10 and IK11. The hammer is released manually and the impact test sample (EUT) is dropped horizontally. This device is often used in lighting standards for impact tests on non-tempered glass. It mainly includes 4 hammers, a host, and bracket casters.
IEC60068-2-75 Environmental testing–Part 2-75: Tests – Test Eh: Hammer tests
IEC62262 Environment testing for electric and electronic products Part 2:Test methods-Test Eh:Hammer tests
| Swing Pipe | Steel pipe 1 (Length: 1000mm, outer diameter: 15.9mm, thickness: 1.5mm) for energy 10J/20J/50J Steel pipe 2 (Length: 1000mm, outer diameter: 16mm, thickness: 0.5mm) for energy 5J Steel pipe 3 (Length: 1000mm, outer diameter: 9.0mm, thickness: 0.5mm) for energies not exceeding 2J | 
| Impact angle | 0~900 | 
| Falling height | 0-500mm adjustable, dial display | 
| Lifting stroke | 200-1200mm | 
| Impact hammers | Striking elements: 2J/0.5KG for IK07 test, 5J/1.7KG for IK08 test, 10J/5KG for IK09 test, 20J/5KG for IK10 test, 50J/10KG for IK11 test, made by steel | 
| Hammer release method | Manual release | 
| Mounting Fixtures | Flat mounting plate, adjustable angle 0-90°, equipped with M6 screw holes | 
Note:
The standard configuration includes 0.5kg, 1.7kg and 5kg hammers for IK 07 to IK10 testing, 10KG hammer for 50J test is a optional device.
| Characteristics 0f Striking Elements | ||||||
| Energy/J | ≤1 ±10% | 2 ±5% | 5 ±5% | 10 ±5% | 20 ±5% | 50 ±5% | 
| Equivalent mass±2%kg | 0.25(0.2) | 0.5 | 1.7 | 5 | 5 | 10 | 
| Material | Nylon | steel | ||||
| R/mm | 10 | 25 | 25 | 50 | 50 | 50 | 
| D/mm | 18.5(20) | 35 | 60 | 80 | 100 | 125 | 
| f/mm | 6.2(10) | 7 | 10 | 20 | 20 | 25 | 
| r/mm | - | - | 6 | - | 10 | 17 | 
| l/mm | Depends | |||||
| Fall Height | |||||||||||||||
| Energy/J | 0.14 | 0.2 | (0.3) | 0.35 | (0.4) | 0.5 | 0.7 | 1 | 2 | 5 | 10 | 20 | 50 | ||
| Equivalent mass/kg | 0.25 | (0.2) | 0.25 | (0.2) | 0.25 | (0.2) | (0.2) | 0.25 | 0.25 | 0 .25 | 0.5 | 1.7 | 5 | 5 | 10 | 
| Fall height±1%mm | 56 | (100) | 80 | (150) | 140 | (200) | (250) | 200 | 280 | 400 | 400 | 300 | 200 | 400 | 500 | 
Degrees of protection against external mechanical impacts
| IK01 | IK02 | IK03 | IK04 | IK05 | IK06 | IK07 | IK08 | IK09 | IK10 | 
| 0.14J | 0.2J | 0.35J | 0.5J | 0.7J | 1J | 2J | 5J | 10J | 20J | 
4.1 The device is purely mechanical manufacturing, should keep regular maintenance, frequent lubrication of screw and bearing bits.
4.2 The device is strictly prohibited from no-load impact, that is, there should be an object under the striking element
4.3 Remove the striking elements when the device is in non-working state.
4.4 Inspect before using, make sure the apparatus placed level.
4.5 Working condition: 5~35℃ (temperature), 45~75% (R.H.)