Sign In | Join Free | My burrillandco.com
Home >

100Gbps QSFP28 ER4 Lite Optical Transceiver Up to 27.952 Gbps Data rate per channel

    Buy cheap 100Gbps QSFP28 ER4 Lite Optical Transceiver Up to 27.952 Gbps Data rate per channel from wholesalers
     
    Buy cheap 100Gbps QSFP28 ER4 Lite Optical Transceiver Up to 27.952 Gbps Data rate per channel from wholesalers
    • Buy cheap 100Gbps QSFP28 ER4 Lite Optical Transceiver Up to 27.952 Gbps Data rate per channel from wholesalers

    100Gbps QSFP28 ER4 Lite Optical Transceiver Up to 27.952 Gbps Data rate per channel

    Ask Lasest Price
    Brand Name : TAKFLY
    Model Number : TKQS28-100G-ER4
    Certification : CE,ROHS,REACH,ISO9001,ISO14001
    Price : US$0.01 ~ US$1200/PC
    Payment Terms : L/C,D/A,D/P,T/T,Western Union,MoneyGram
    Delivery Time : 3-7working days
    • Product Details
    • Company Profile

    100Gbps QSFP28 ER4 Lite Optical Transceiver Up to 27.952 Gbps Data rate per channel

    Description
    • TKQS28-100G-ER4 is a 100Gb/s transceiver module designed for optical communication applications compliant to Ethernet 100GBASE-ER4 Lite standard. The module converts 4 input channels of 25Gb/s electrical data to 4 channels of LANWDM optical signals and then multiplexes them into a single channel for 100Gb/s optical transmission. Reversely on the receiver side, the module de-multiplexes a 100Gb/s optical input into 4 channels of LANWDM optical signals and then converts them to 4 output channels of electrical data.
    • The central wavelengths of the 4 LAN WDM channels are 1295.56, 1300.05, 1304.58 and 1309.14nm as members of the LANWDM wavelength grid defined in IEEE802.3ba.The high performance cooled LAN WDM EA-DFB transmitters and high sensitivity APD receivers provide superior performance for 100Gigabit Ethernet applications up to 30km links without FEC and 40km links with FEC.
    • The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP+ Multi-Source Agreement (MSA).It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.

    Functional Description

    1. The transceiver module receives 4 channels of 25Gb/s electrical data, which are processed by a 4-channel Clock and Data Recovery (CDR) IC that reshapes and reduces the jitter of each electrical signal. Subsequently, EML laser driver IC converts each one of the 4 channels of electrical signals to an optical signal that is transmitted from one of the 4 cooled EML lasers which are packaged in the Transmitter Optical Sub-Assembly (TOSA). Each laser launches the optical signal in specific wavelength specified in IEEE802.3ba 100G BASE-ER4 requirements. These 4-lane optical signals will be optically multiplexed into a single fiber by a 4-to-1 optical WDMMUX. The optical output power of each channel is maintained constant by an automatic power control (APC) circuit. The transmitter output can be turned off by TX_DIS hardware signal and/or 2-wire serial interface.
    • The receiver receives 4-lane LANWDM optical signals. The optical signals are de-multiplexed by a 1-to-4 optical DEMUX and each of the resulting 4 channels of optical signals is fed into one of the 4 receivers that are packaged into the Receiver Optical Sub-Assembly (ROSA). Each receiver converts the optical signal to an electrical signal. The regenerated electrical signals are retimed and de-jittered and amplified by the RX portion of the 4-channel CDR. The retimed 4-lane output electrical signals are compliant with CEI-28G-VSR interface requirements. In addition, each received optical signal is monitored by the DOM section. The monitored value is reported through the 2-wire serial interface. If one or more received optical signal is weaker than the threshold level, RX_LOS hardware alarm will be triggered.
    • A single +3.3V power supply is required to power up this product. Both power supply pins VccTx and VccRx are internally connected and should be applied concurrently. As per MSA specifications the module offers 7 low speed hardware control pins (includingthe2-wireserialinterface): ModSelL, SCL, SDA, ResetL, LPMode, ModPrsL and IntL.
    • Module Select (ModSelL) is an input pin. When held low by the host, this product responds to 2-wire serial communication commands. The ModSelL allows the use of this product on a single2-wireinterface bus – individual ModSelL lines must be used.
    • Serial Clock (SCL) and Serial Data (SDA) are required for the 2-wire serial bus communication interface and enable the host to access the QSFP28 memory map.
    • The ResetL pin enables a complete reset, returning the settings to their default state, when a low level on the ResetL pin is held for longer than the minimum pulse length. During the execution of a reset the host shall disregard all status bits until it indicates a completion of the reset interrupt. The product indicates this by posting an IntL (Interrupt) signal with the Data_Not_Ready bit negated in the memory map. Note that on power up (including hot insertion) the module should post this completion of reset interrupt without requiring a reset.
    • Low Power Mode (LPMode) pin is used to set the maximum power consumption for the product in order to protect hosts that are not capable of cooling higher power modules, should such modules be accidentally inserted
    • Module Present (ModPrsL) is a signal local to the host board which, in the absence of a product, is normally pulled up to the host Vcc. When the product is inserted into the connector, it completes the path to ground through a resistor on the host board and asserts the signal. ModPrsL then indicates its present by setting ModPrsL to a “Low” state.
    • Interrupt (IntL) is an output pin. “Low” indicates a possible operational fault or a status critical to the host system. The host identifies the source of the interrupt using the 2-wire serial interface. The IntL pin is an open collector output and must be pulled to the Host Vcc voltage on the Host board.


    Features

    Ø Hot pluggable QSFP28 MSA form factor

    Ø Compliant to Ethernet 100GBASE-ER4 Lite

    Ø Supports 103.1Gb/s aggregate bit rate

    Ø Up to 30km reach for G.652 SMF without FEC

    Ø Up to 40km reach for G.652 SMF with FEC

    Ø Single +3.3V power supply

    Ø Operating case temperature: 0~70oC

    Ø Transmitter: cooled 4x25Gb/s LAN WDM EML TOSA (1295.56, 1300.05, 1304.58, 1309.14nm)

    Ø Receiver: 4x25Gb/s APD ROSA

    Ø 4x25G electrical interface (OIF CEI-28G-VSR)

    Ø Maximum power consumption 4.5W

    Ø Duplex LC receptacle

    Ø RoHS-6 compliant


    Applications

    Ø 100GBASE-LR4 Ethernet Links

    Ø Infiniband QDR and DDR interconnects

    Ø Client-side 100G Telecom connections


    Transceiver Block Diagram

    Figure 1. Transceiver Block Diagram



    Pin Assignment and Description

    Figure 2. MSA compliant Connector

    Pin Definition

    PIN

    Logic

    Symbol

    Name/Description

    Note s


    1

    GND

    Ground

    1


    2

    CML-I

    Tx2n

    Transmitter Inverted Data Input


    3

    CML-I

    Tx2p

    Transmitter Non-Inverted Data output


    4

    GND

    Ground

    1


    5

    CML-I

    Tx4n

    Transmitter Inverted Data Input


    6

    CML-I

    Tx4p

    Transmitter Non-Inverted Data output


    7

    GND

    Ground

    1


    8

    LVTLL-I

    ModSelL

    Module Select


    9

    LVTLL-I

    ResetL

    Module Reset


    10

    VccRx

    +3.3V Power Supply Receiver

    2


    11

    LVCMOS-I/O

    SCL

    2-Wire Serial Interface Clock


    12

    LVCMOS-I/O

    SDA

    2-Wire Serial Interface Data


    13

    GND

    Ground


    14

    CML-O

    Rx3p

    Receiver Non-Inverted Data Output


    15

    CML-O

    Rx3n

    Receiver Inverted Data Output


    16

    GND

    Ground

    1


    17

    CML-O

    Rx1p

    Receiver Non-Inverted Data Output


    18

    CML-O

    Rx1n

    Receiver Inverted Data Output


    19

    GND

    Ground

    1


    20

    GND

    Ground

    1


    21

    CML-O

    Rx2n

    Receiver Inverted Data Output


    22

    CML-O

    Rx2p

    Receiver Non-Inverted Data Output


    23

    GND

    Ground

    1


    24

    CML-O

    Rx4n

    Receiver Inverted Data Output

    1


    25

    CML-O

    Rx4p

    Receiver Non-Inverted Data Output


    26

    GND

    Ground

    1


    27

    LVTTL-O

    ModPrsL

    Module Present


    28

    LVTTL-O

    IntL

    Interrupt


    29

    VccTx

    +3.3 V Power Supply transmitter

    2


    30

    Vcc1

    +3.3 V Power Supply

    2


    31

    LVTTL-I

    LPMode

    Low Power Mode


    32

    GND

    Ground

    1


    33

    CML-I

    Tx3p

    Transmitter Non-Inverted Data Input


    34

    CML-I

    Tx3n

    Transmitter Inverted Data Output


    35

    GND

    Ground

    1


    36

    CML-I

    Tx1p

    Transmitter Non-Inverted Data Input


    37

    CML-I

    Tx1n

    Transmitter Inverted Data Output

    38

    GND

    Ground

    1

    Notes:

    1. GND is the symbol for signal and supply (power) common for the QSFP28 module. All are common within the module and all module voltages are referenced to this potential unless otherwise noted. Connect these directly to the host board signal common ground plane.

    2.VccRx, Vcc1 and VccTx are the receiving and transmission power suppliers and shall be applied concurrently. Recommended host board power supply filtering is shown in Figure3 below. VccRx, Vcc1 and VccTx may be internally connected within the module in any combination. The connector pins are each rated for a maximum current of 1000mA.


    Recommended Power Supply Filter

    Figure 3. Recommended Power Supply Filter


    Absolute Maximum Ratings

    It has to be noted that the operation in excess of any individual absolute maximum ratings might cause permanent damage to this module.

    Parameter

    Symbol

    Min

    Max

    Units

    Notes

    Storage Temperature

    TS

    -40

    85

    degC

    Operating Case Temperature

    TOP

    0

    70

    degC

    Power Supply Voltage

    VCC

    -0.5

    3.6

    V

    Relative Humidity (non-condensation)

    RH

    0

    85

    %

    Damage Threshold, each Lane

    THd

    -3.0

    dBm



    Recommended Operating Conditions and Power Supply Requirements

    Parameter

    Symbol

    Min

    Typical

    Max

    Units

    Notes

    Operating Case Temperature

    TOP

    0

    70

    degC

    Power Supply Voltage

    VCC

    3.135

    3.3

    3.465

    V

    Data Rate, each Lane

    25.78125

    Gb/s

    Data Rate Accuracy

    -100

    100

    ppm

    Control Input Voltage High

    2

    Vcc

    V

    Control Input Voltage Low

    0

    0.8

    V

    Link Distance with G.652 (without FEC)

    D1

    30

    km

    1

    Link Distance with G.652 (with FEC)

    D2

    40

    km

    1

    Notes:

    1.Depending on actual fiber loss/km (link distance specified is for fiber insertion loss of0.4dB/km)

    Electrical Characteristics

    The following electrical characteristics are defined over the Recommended Operating Environment unless otherwise specified.

    Parameter

    Test Poin

    Min

    Typical

    Max

    Units

    Notes

    Power Consumption

    4.5

    W

    Supply Current

    Icc

    1.36

    A

    Transmitter(each Lane)

    Overload Differential Voltage pk-pk

    TP1a

    900

    mV

    Common Mode Voltage (Vcm)

    TP1

    -350

    2850

    mV

    1

    Differential Termination

    TP1

    10

    %

    At1MHz

    Differential Return Loss (SDD11)

    TP1

    SeeCEI-28G-VSR

    dB

    Common Mode to Differential conversion and Differential to Common

    TP1

    SeeCEI-28G-VSR

    dB

    Stressed Input Test

    TP1a

    SeeCEI-28G-VSR

    Receiver (each Lane)

    Differential Voltage, pk-pk

    TP4

    900

    mV

    Common Mode Voltage (Vcm)

    TP4

    -350

    2850

    mV

    1

    Common Mode Noise, RMS

    TP4

    17.5

    mV

    Differential Termination

    TP4

    10

    %

    At1MHz

    Differential Return Loss (SDD22)

    TP4

    SeeCEI-28G-VSR

    dB

    Common Mode to Differential conversion and Differential to Common Mode

    TP4

    SeeCEI-28G-VSR

    dB

    Common Mode Return Loss (SCC22)

    TP4

    -2

    dB

    2

    Transition Time, 20 to 80%

    TP4

    9.5

    ps

    Vertical Eye Closure (VEC)

    TP4

    5.5

    dB

    Eye Width

    at 10-15probability(EW15)

    TP4

    0.57

    UI

    Eye Height

    at 10-15probability(EH15)

    TP4

    228

    mV

    Notes:

    1.Vcm is generated by the host. Specification includes effects of ground offset voltage.

    2.From 250MHz to30GHz.

    Optical Characteristics

    Ethernet 100GBASE-ER4Lite


    Parameter

    Symbol

    Min

    Typical

    Max

    Units

    Notes


    Lane Wavelength

    L0

    1294.53

    1295.56

    1296.59

    nm


    L1

    1299.02

    1300.05

    1301.09

    nm


    L2

    1303.54

    1304.58

    1305.63

    nm


    L3

    1308.09

    1309.14

    1310.19

    nm


    Transmitter


    SMSR

    SMSR

    30

    dB


    Total Average Launch Power

    PT

    10.5

    dBm


    Average Launch Power, each Lane

    PAVG

    -2.9

    4.5

    dBm

    1


    OMA, each Lane

    POMA

    0.1

    4.5

    dBm

    2


    Difference in Launch Power between any Two Lanes(OMA)

    Ptx, diff

    3.6

    dB


    Launch Power in OMA minus Transmitter and Dispersion Penalty(TDP), each Lane

    -0.65

    dBm


    TDP, each Lane

    TDP

    2.5

    dB


    Extinction Ratio

    ER

    7

    dB


    RIN20OMA

    RIN

    -130

    dB/Hz


    Optical Return Loss Tolerance

    TOL

    20

    dB


    Transmitter Reflectance

    RT

    -12

    dB


    Average Launch Power OFF Transmitter, each Lane

    Poff

    -30

    dBm


    Eye Mask{X1, X2, X3, Y1, Y2,Y3}

    {0.25, 0.4, 0.45, 0.25, 0.28,0.4}


    Receiver


    Damage Threshold, each Lane

    THd

    -3.0

    dBm

    3


    Average Receive Power, each Lane

    -16.9

    -4.9

    dBm

    for 30km

    Link Distanc

    Average Receive Power, each Lane

    -20.9

    -4.9

    dBm

    for 40kmLinkDistance

    Receive Power (OMA), each Lane

    -1.9

    dBm

    Receiver Sensitivity (OMA),each

    Lane

    SEN1

    -14.65

    dBm

    For BER

    =1x10-12

    Stressed Receiver Sensitivity(OMA), each Lane

    -12.65

    dBm

    For BER

    =1x10-12

    Receiver Sensitivity (OMA),each Lane

    SEN2

    -18.65

    dBm

    For BER

    =5x10-5

    Stressed Receiver Sensitivity(OMA), each Lane

    -16.65

    dBm

    For BER

    =5x10-5

    Receiver reflectance

    -26

    dB

    Difference in Receive Power between any Two Lanes(Average and OMA)

    Prx, diff

    3.6

    dB

    LOS Assert

    LOSA

    -26

    dBm

    LOS Deassert

    LOSD

    -24

    dBm

    LOS Hysteresis

    LOSH

    0.5

    dB

    Receiver Electrical 3 dB upper Cutoff Frequency, each Lane

    Fc

    31

    GHz

    Conditions of Stress Receiver Sensitivity Test (Note4)

    Vertical Eye Closure Penalty, each Lane

    1.5

    dB

    Stressed Eye J2 Jitter, each Lane

    0.3

    UI

    Stressed Eye J9 Jitter, each Lane

    0.47

    UI

    Notes:

    1.The minimum average launch power spec is based on ER not exceeding 9.5dB and transmitter OMA higher than0.1dBm.

    2.Even if the TDP < 0.75 dB, the OMA min must exceed the minimum value specified here.

    3.having this power level on one lane. The receiver does not have to operate correctly at this input power.

    4.The receiver shall be able to tolerate, without damage, continuous exposure to a modulated optical input signal Vertical eye closure penalty, stressed eye J2 jitter, and stressed eye J9 jitter are test conditions for measuring stressed receiver sensitivity. They are not characteristics of the receiver.

    Digital Diagnostic Functions

    The following digital diagnostic characteristics are defined over the normal operating conditions unless otherwise

    specified.

    Parameter

    Symbol

    Min

    Max

    Units

    Notes

    Temperature monitor absolute error

    DMI_Temp

    -3

    +3

    degC

    Over operating temperature range

    Supply voltage monitor absolute error

    DMI_VCC

    -0.1

    0.1

    V

    Over full operating range

    Channel RX power monitor absolute error

    DMI_RX_Ch

    -2

    2

    dB

    1

    Channel Bias current monitor

    DMI_Ibias_Ch

    -10

    10

    mA

    Channel TX power monitor absolute error

    DMI_TX_Ch

    -2

    2

    dB

    1

    Notes:

    Due to measurement accuracy of different single mode fibers, there could be an additional +/-1dB fluctuation, or a +/- 3 dB total accuracy.



    Mechanical Dimensions

    Figure 4. Mechanical Outline


    ESD

    Thistransceiver is specified as ESD threshold 1kV for SFI pins and 2kV for all other electrical input pins, tested per MIL-STD-883, Method 3015.4 /JESD22-A114-A (HBM).

    However, normal ESD precautions are still required during the handling of this module.This transceiver is shipped in ESD protective packaging. It should be removed from the packaging and handled only in an ESD protected environment.


    Laser Safety

    This is a Class1 Laser Product according to EN60825-1:2014. This product complies with 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50, dated (June 24,2007).

    Caution: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.

    Quality 100Gbps QSFP28 ER4 Lite Optical Transceiver Up to 27.952 Gbps Data rate per channel for sale
    • Haven't found right suppliers
    • Our buyer assistants can help you find the most suitable, 100% reliable suppliers from China.
    • And this service is free of charge.
    • we have buyer assistants who speak English, French, Spanish......and we are ready to help you anytime!
    Submit Buying Request
    Send your message to this supplier
    *From:
    Your email address is incorrect!
    *Subject:
    Your subject must be between 10-255 characters!
    *Message:
    For the best results, we recommend including the following details:
    • --Self introduction
    • --Required specifications
    • --Inquire about price/MOQ
    Your message must be between 20-3,000
    Yes! I would like your verified suppliers matching service!
    Send your message to this supplier
     
    *From:
    *To: TAKFLY COMMUNICATIONS CO., LTD.
    *Subject:
    *Message:
    Characters Remaining: (0/3000)
     
    Explore more Optical Transceiver Module products from this supplier
    Inquiry Cart 0