Gapless Metal Oxide Surge Arrester , 10 KV Lightning Arrester
|
10kV Cut-off Polymer/ Porcelain Gapless Surge Arrester Product introduction: This kind of cut-off SA could be used in transmission system below 10kV. It combines advantages of cut-off fuse and SA. Polymer-housed metal oxide surge arrester (MOA) combines ......
Shendian Electric Co. Ltd
|
630A 35KV Station Type Zinc Oxide Lightning Arrester
|
... ≤KV 30/60μs Switching Current Impulse (≤KV) 2msRectangular Current Impulse(2ms) (A) 4/10μs High Current Impulse (KA) KV(r.m.s) HY1.5W-0.28/1.3 0.22 0.28 0.24 0.6 1.3 75 25 HY1.5W-0.5/2.6 0.38 0.5 0.42 1.2 2.6 75 25 HY5WS-3.8/......
WENZHOU QIUPU ELECTRIC POWER CO., LTD.
|
11Kv High Voltage Outdoor Porcelain Lightning Arrester
|
...20ms 30/60Switching 2000μs Rectangular 4/10Current (kV) operating current Lightning current wave withstand voltage residual current residual current discharge (kV≥) voltage residual voltage impulse(A) capacity (kV≤) voltage (kV≤) (kA) (kV≤) HY5W-3...
ZHEJIANG XINKOU POWER EQUIPMENT CO.,LTD
|
YH5W 12kv 15kv Expoxy House Zinc Oxide Lightning Arrester
|
...Lightning Arrester Surge Arrestor Gapless Arrester Electrical Parameter Type Rated Voltage MCOV Max.Residual Viltage 2ms square wave impulse withstand current High current impulse withstand 4/10μs Steep current impuise1/4μS Switching current lmpulse30/60μs Nominal current lmpulse 8/20μs kV kV kV kV kV A kV......
Xi'an Xigao Electricenergy Group Co., Ltd.
|
YH10W-21 Polymer Lightning Arrester 21kV 10kA Substation
|
...Lightning impulse withstand 125/150KV Type YH5W5-21/56 Rated voltage---------kV 21 MOCV ----------------kV 17 Nominal Current-------kV 10 Residual voltage of steep impulse----at 5kA(kV) 60.5 8/20µS Residual voltage of lightning impulse current kV(Peak value)-----at 5kA(kV) 56 Residual voltage of switching...
Hangzhou Yongde Electric Appliances Co.,Ltd
|
Transmission Line IEC 60168 24kV Lightning Arrester Insulator
|
... power line Lightning Arrester Insulator/ OEM available Descriptions: Model Rated voltage(kV) Height (mm) Min. nominal creepage distance(mm) Cantilever strength (kN) Torsion strength (kN.m) Weight (Kg) ZSW-24/10 24 350 600 10 1 20 We offers a wide......
Changsha Power Electric Co.,Ltd.
|
Early Streamer Lightning Arrester For Building 304 Superior Stainless Steel Shell
|
...lightning arrester installation manual / diagram Advantages Technical Data of TSTLP Early streamer lightning arresters Models SMT-ESE60 SMT-ESE50 SMT-ESE40 SMT-ESE30 Patent Number 2013300191382 2013300191397 2013300320345 2013300191363 Efficiency 60μs 50μs 40μs 30μs Iimp 100kA (normative withstanding test at 10/350μs waveform as standard requires) Lightning current withstanding Iimp ≥ 200kA (10......
TS Lightning Protection Co.,Limited
|
ESE Early Discharge Lightning Arrester Earthing , Lightning Arrester Pole Single Pin
|
..., the lightning current to earth, and make the protected antenna pole or building does not occur side strike and charged. In most cases the impact of the electrostatic field cable is less than 1/10 of the impedance of the tower, avoiding the building or...
Hunan Heou Engineering Consulting Co., Ltd
|
Pluggable Class 1 + 2 (B + C) Lightning Arrester Surge Protector SPD 10/350 12.5kA 4P
|
...2 (B + C) SPD 10/350 12.5kA 4P Surge Protector Pluggable Class 1 + 2 (B + C) Lightning Arrester Surge Protector Product Description: • Combined Type 1+2/Class I+II surge protection devices. • Modular type. • Lightning impulse current (10/350μs): 12......
Britec Electric Co., Ltd.
|
IEC60099 Standard ZnO Discs Lightning Arrester Material D39 D42 D45 D46 D48
|
Main Specification of AC Metal Oxide Varistor Type Overall dimension (mm) A.C.reference voltage U1mA (reference current is 1mA)(kV) (UxkA/U1mA D C) Max. ratio of residual voltage (UxkA/U1mA D C) (at 8/20µs) Current impulse withstand capability Recommend-ed......
Nanyang Xinda Electro-Mechanical Co., Ltd.
|
