FSS1500NST FSS1500NGT Force Sensors And Load Cells Power supply 3.3V~12.5V for Accurate Measurements
![]() |
... Cycles to Failure (MCTF) at 25 °C [77 °F] rating. This low profile Surface Mount Technology (SMT) sensor allows for automated assembly on a printed circuit board, often helping the customer to reduce assembly costs. The FSS-SMT Series force sensor is...
ShenzhenYijiajie Electronic Co., Ltd.
|
100-500N FA101 Mini Force Sensor Stainless Steel Button Force Measurement Transducers
![]() |
...Miniature Force Sensor FA101 can be used to measure force 100N,200N,500N capacity, its Rated output range is 1.0±20% mV/V, and its Zero balance range is ±1%F.S., its Cable size is ⌀2x3000mm. In the measurement process of the micro-pressure sensor, the...
Fibos Measurement Technology (Changzhou) Co., Ltd.
|
Multi Axis Force Sensor 200lb 100lb 50lb 20lb 10 lbs 3-Axis Load Cell
![]() |
... tension and compression direction with 0-4.5 lb / 0-6.7lb / 0-11lb / 0-22 lb / 0-45lb / 0-67lb / 0-112 lb / 0-225lb eight measuring ranges to choose from.Very low profile design with total 26mm height makes F3G suitable for 3-axis force measurement where...
Forsentek Co., Limited
|
Aluminum Alloy Force Sensor Load Cell For Torque Force Measurement
![]() |
...e of Aluminum alloy Delicate structure Static torqie sensor Description: Static torque sensor with metal foil strain gauge technology and compact structure. Made of aluminum alloy, there are six holes on both sidez of the load cell, this makes it ......
tecsis (Shenzhen) Sensors Co., Ltd
|
Measuring Cell Shackles Force Sensors Underwater Load Cell Measuring Crosby Cell Load Cell
![]() |
... execution for harsh environmental conditions (IP66); High reliability for strict safety requirements; Simple installation for cost-saving solutions to measurement problems; Description:...
Xian Ruijia Measurement Instruments Co., Ltd.
|
Rubber Sleeve Rebound Tester for Accurate Measurements
![]() |
...measure and evaluate the ability of the lancet sleeve to return to its original shape after being squeezed or stretched by an external force. The tester uses high-precision force sensors and displacement sensors to monitor the force value change and deformation of the rubber sleeve in real time during the recovery process, so as to evaluate its resilience force...
Hai Da Labtester
|
5~100kg Stainless Steel Mini Force Sensor IN-MI-012
![]() |
...Stainless Steel Mini Force Sensor IN-MI-012 Force measurement in small space installation, such as feeling tester for keyboard switch, compression force measurement for hot and cold lamination machine, and grasping force measurement for robotic hands MODLE......
Innovation Electronic Co.,Ltd
|
ADXL213AE-REEL Precision Accelerometer Sensor for Accurate Measurements
![]() |
...Sensor for Accurate Measurements Product Listing: ADXL213AE-REEL - Accelerometer Sensor Key Features: • Small, Low Profile Package: The ADXL213AE-REEL is a small, low profile accelerometer sensor that measures acceleration along one or two axes. • High Sensitivity: The sensor has a sensitivity range of ±2g, so it can detect even small changes in acceleration. • Low Power Consumption: The sensor......
Shenzhen Sai Collie Technology Co., Ltd.
|
Highly Accurate Skin Temperature Sensor NTC Temperature Sensor
![]() |
...Accurate Skin Temperature Sensor NTC Temperature Sensor Quick Details *The Skin Temperature Probe (2 m) is specifically designed for temperature monitoring requiring repeatability, high sensitivity and rapid response. *Measurement Specialties patented manufacturing techniques ensure that probes are interchangeable within the same series *Designed for measurement of patient's temperature *Highly accurate skin sensor......
Guangdong Uchi Electronics Co.,Ltd
|
KCD310 COD Turbidity Temperature Sensor for Fast Response and Accurate Measurement
![]() |
...Sensor no reagents no pollution small size more convenient COD turbidity and temperature 1.Principle Many organic compounds dissolved in water absorb ultraviolet light. Therefore, the content of dissolved organic pollutants in water can be accurately measured by measuring the absorption of these organic compounds to 254 nm wavelength UV light. KCD310 online COD sensor uses two light sources, one ultraviolet light to measure......