| Sign In | Join Free | My burrillandco.com |
|
...sensor 3m sensing range selling well in the market Quick details: Name: U type diffuse sensor Type: diffuse type Distance: 300mm. Output: PNP / NPN , NO/NC Technical Specification: M18 10-30v dc NPN PNP diff...
... cell is available in a capacity range from 50N to 5000N for all three axes. The three-dimensional force sensor is based on the strain transducer and adopts the resistance strain transducer principle. The 30...
...Sensor U18 Analog Current Output 4-20mA Up/down 50-500mm Detection Range Ultrasonic sensor U118-D500IT-R00A has detection range 50-500mm, it supply voltage 10-30VDC,reverse-polarity protection. Analog curren...
... accurate and reliable readings. The radiometric output ranges from 0.5 to 4.5Vdc, providing a wide range of options for data collection and analysis. This sensor is designed to operate in extreme temperatur...
...offers improved temperature resolution of 0.125 °C and specification of a single part over power supply range from 2.8 V to 5.5 V Small 8-pin package types: SO8 and TSSOP8 I2 C-bus interface with up to 8 dev...
...Sensor for Boom Barrier Systems - 30m Range, Anti-Strong Sunlight, 0.1s Fast Trigger Ultimate Precision for High-Traffic Access Control Designed to meet the rigorous demands of modern traffic management, the...
...Sensor - 12-24V Dual Power, 20m Range, Sunlight Immunity Mission-Critical Precision for Industrial Automation Engineered to redefine safety in high-stakes environments, the Rapid Response IR Photoelectric Se...
...Sensor Combustion Efficiency For Fixed Gas Detector It is suitable for measuring the oxygen content of flue gas by flue gas analyzer and measuring the combustion efficiency. Specification: Temperature range ...
... Datasheet: Rec. Load Resistor 10 - 33 Ω Bias (V_Sens-V_Ref) not recommended Relative Humidity Range 15 % to 90 % RH non-condensing Temperature Range -10 °C to 50 °C Pressure Range Atmospheric ± 10% Pressure...
... 10 - 33 Ω Bias (V_Sens-V_Ref) not recommended Conformity to RoHS directive RoHS Compliance Relative Humidity Range 15 % to 90 % RH non-condensing Temperature Range -40 °C to 50 °C Pressure Range Atmospheric...
...Sensor Highly Sensitive NH3 Measurement 3 Electrode Electrochemical Applications •Leak Detection • Discontinuous Measurement • Safety and Environmental Control Specification Rec. Load Resistor 10 - 33 Ω Bias...
...75C Combustion Gas Sensor Catalytic Oxidation How it works: catalytic oxidation Range: 0-100% LEL Sensitivity: 31 ± 5 mV/% methane T90 response time: <5 seconds (methane) Operating temperature range: -20°C to +55°C Operating humidity range: 0-90% RH wit......
Product Description: 4CF+ 2112B2005 Carbon Monoxide Gas Sensor 3 Electrode Electrochemical Use For Industry Features: Temperature range of -30-50 Pressure range Kpa 80-120 Humidity range %RH 15-90 Storage tim...
... Nitrogen Gas Detection Sensor 3-electrode electrochemical 0 - 100ppm NO2 Features: Range: 0 ~ 100 PPM Maximum range: 1000PPM Service life: 2 years in air Output signal: 0.37±0.07uA /PPM Resolution: 0.5PPM O...
...Sensor Short Warm Up Time Quick response • Low noise • No electrolyte leakage • Low cost for high volume • Extremely linear response at high concentrations • Individual calibration including test repor...
...Sensor 3-Electrode Electrochemical In Standard Housing Applications • Continuous Air Quality Monitoring • Safety and Environmental Control Environmental Relative Humidity Range 15 % to 90 % RH non-condensing...
...Sensor Constant Current Features: Working voltage 2.7v + 0.2v The operating current of 200 MA power consumes 580 MW at a methane concentration of 5% v/v Air with an expected service life of more than 5 years...
O2-G2 Oxygen Gas Sensor Electrochemical Small Size 2 Years Working Life 7G Weight O2-G2 Applications: 1. Oxygen alarm 2. Atmosphere Analyzer Datasheet: Temperature Range -30 - 55C Pressure range 80 - 120Kpa Hum...
...Sensor With 0.1 Ppm Resolution Maximum Overload Of 50 Ppm Part Number CLE-0911-400 Nominal Range 0-10 ppm Maximum Overload 50 ppm Sensitivity 0.75± 0.15 uA/ppm Baseline(20 oC < ±0.1 uA Baseline drift 0 ~ -0....
...Sensor 3 Electrode Electrochemical Applications • Stack/ Flue Gas Monitoring • Emission Monitoring Electrical Rec. Load Resistor 10 - 33 Ω Bias (V_Sens-V_Ref) Not recommended Conformity to RoHS directive RoH...