...Insulators For Distribution Lines brown pin type insulator specification: Name P-11-Y P-33-Y P-36-Y Creepage distance (mm) 254 630 900 Cantilever strength (kn) 11 11 10 Type application voltage KV 11 33 36 P...
...Insulators With Zinc Sleeve color white , IEC standard Technical Specification Unit Value 1 Spacing mm 170 2 Shed Diameter mm 320 3 Creepage Distance mm 450 4 Coupling Size 20 5 Rated M&E Strength KN 160...
...Insulator Item Technical data Rated voltage (KV) 12 Rated frequency(Hz) 50 Insulator(capacity) insulating Frequency withstand voltage 5 min (KV) 42 Frequency withstand voltage 1 min (V) 2000 Lighting impulse...
... voltage Critical impulse flashover voltage Test voltage to ground (kV) Dry(kV) Wet(kV) Positive(kV) 57-3 737 311 12.5 125 95 200 30 Line post insulators shall conform in all respects to the requirements of ...
...Insulator ANSI C29.7 F neck / light gray Descriptions: ANSI CLASS Creepage distance (mm) Dry arcing distance (mm) cantilever strength (kN) Lower frequency flashover voltage Critical impulse flashover voltage...
... voltage Critical impulse flashover voltage Test voltage to ground (kV) Dry(kV) Wet(kV) Positive(kV) 57-3 737 311 12.5 125 95 200 30 1. Line post insulators shall conform in all respects to the requirements ...
...insulator Descriptions: ANSI CLASS Creepage distance (mm) Dry arcing distance (mm) cantilever strength (kN) Lower frequency flashover voltage Critical impulse flashover voltage Test voltage to ground (kV) Dr...
...Insulator/ Light gray with semi-conductive glaze Descriptions: ANSI CLASS Creepage distance (mm) Dry arcing distance (mm) cantilever strength (kN) Lower frequency flashover voltage Critical impulse flashover...
...insulator in blue color Descriptions: ANSI CLASS Creepage distance (mm) Dry arcing distance (mm) Cantilever strength(kN) Low frequency punture voltage(kV) Low frequency flashover voltage(kV) Weight (kg) Dry(...
...insulator 11KV / no glaze body Descriptions: ANSI CLASS Creepage distance (mm) Dry arcing distance (mm) cantilever strength (kN) Lower frequency flashover voltage Critical impulse flashover voltage Test volt...
... Distance mm 800 4 Mechanical failing load Strength Min. KN 70 6 Power Frequency withstand Voltage dry KV 110 wet KV 95 7 Lightning Impulse withstand Voltage ...
...insulator with porcelain thread brown for distribution lines Description: ANSI standard pin type insulator technical performance listed below : Technical Specification Unit Value 1 Total Height mm 318 2 Ma...
...insulator U420B with light green color Description: Technical Specifications for U420B toughened glass insulator : Technical Specification Unit Value 1 Spacing mm 205 2 Shed Diameter mm 380 3 Creepage Dist...
...insulator U300BP with light green color Description: Technical Specifications for U300BP toughened glass insulator : Technical Specification Unit Value 1 Spacing mm 195 2 Shed Diameter mm 380 3 Creepage Di...
...outer sheathed cable.The three ×LPE insulated and copper tape screened single core cables are bundled around the galvanized steel wires in a right hand lay. 12/20(24)kv aerial bundled cable overhead insulate...
...kV, 10 kV, 6 kV, 450/750V Size 5*2.5 mm², 1*0.5 mm², 1*0.75 mm², 1*25.0 mm² Conductor Material 100% Copper Insulation Material PVC Working Temperature 90°C (-40℃~90℃) Jacket Nylon Application Industrial, Bui...
...insulated steel belt armored PVC sheath power cable ▼ Application: 6 kV up to 30 kV for fixed installations such as distribution networks or industrial installations. ▼ Constraction: Core Conductor annealed ...
...Insulators Specifications: Cat.No QS11354S / QS11354L Class ANSI 57-5S / 57-5L Creepage Distance(mm) 1143 Dry Arcing Distance(mm) 438 Cantilever Strength(KN) 12.5 Low Frequency Dry Flashover(KV) 175 Low Freq...
...-time working temperature : PVC or PE insulated conductor is not more than 70 ,and that of XLPE insulation is not more than 90 . 3) Installing temperature should not be below -20 . 4) bending radius to cable...