| Sign In | Join Free | My burrillandco.com |
|
GAVR-20A Product Description TECHNICAL DATA SENSING INPUT Voltage: 220/400 VAC POWER INPUT Voltage: 170~270VAC,1 phase 2 wire MAGNETIC FIELD OUTPUT Voltage: Max 90VDC, 240VAC input Current: Continous 20A Contac...
GAVR-15A Product Description TECHNICAL DATA SENSING INPUT Voltage: 220/400 VAC POWER INPUT Voltage: 170~270VAC,1 phase 2 wire MAGNETIC FIELD OUTPUT Voltage: Max 95VDC, 240VAC input Current: Continous 15A Contac...
GAVR-8A Product Description TECHNICAL DATA SENSING INPUT Voltage: 110/220/400 VAC POWER INPUT Voltage: 95-270VAC, 1 phase 2 wire MAGNETIC FIELD OUTPUT Voltage: 95VDC, 240VAC Input Current: Continous 8A Contact ...
WT-2 Product Description TECHNICAL DATA SENSING INPUT Voltage: 170~480VAC POWER INPUT Voltage: 170~270VAC, 1 phase 2 wire MAGNETIC FIELD OUTPUT Voltage: Max 100VDC at 240VAC input Current: continuous 15A Contac...
WT-3 Product Description TECHNICAL DATA SENSING INPUT Voltage: 170~480VAC POWER INPUT Voltage: 40~150VAC, 3 phase MAGNETIC FIELD OUTPUT Voltage: Max 90VDC at 240VAC input Current: continuous 6A Contact Person :...
... 1 3x380/220V 3x100/57.5V 1.5(6), 3(6), 5(30), 10(50), 15(90), 20(100), 5(40). 5(100) Class 2 Three phase three phase active energy electronic type Watt-hour meter DS1250SA Class 1 3 x 100V 3 x 380V Class 2 ...
.../48KW 80KVA/64KW Phase 3 Phase in and 3 phase out Input Voltage Range 210-475 VAC Frequency Range 40Hz~70Hz, 56/60Hz(AutoSensing) THDI <3% Power Factor >0.99 ......
.../48KW 80KVA/64KW Phase 3 Phase in and 3 phase out Input Voltage Range 210-475 VAC Frequency Range 40Hz~70Hz, 56/60Hz(AutoSensing) THDI <3% Power Factor >0.99 ......
...Phase Meter Test Bench Technical Data YC1891D-6 YC1891D-12 YC1891D-24 YC1891D-48 Number of meter positions 6 12 24 48 Accuracy 0.05 Power Source YCS-101-250 YCS-101-600 YCS-101-1200 YCS-101-2500 Standard Met...
...Phase Pole Mounted Transformer Oil Liquid 34500V to 120V The pole-mounted transformers produced by WINLEY ELECTRIC have rated capacities ranging from 10 kVA to 333 kVA, meeting ANSI/IEEE C57, IEC60076 and ot...
...Phase Pole Mounted Transformer 4.16KV To 120V Oil Immersed Power Pole Transformer ANSI IEEE Standard C57 Winley Electric’s UL/cUL certified pole-mounted transformers feature a 10–333 kVA capacity and comply ...
...lagging) The regulating rate of steady voltage ≤±0.5% The regulating rate of instantaneous voltage ≤-15%/ +20% The time of steady voltage ≤1.5sec The waving rate of voltage ≤1.0% The regulating rate of stead...
...phase generator 250kva powered by Cummins NT855GA for sale Technical data Genset Model SC250E6 Prime Power 200KW/250KVA Rated Voltage 400/230V Frequency 60Hz Power Factor 0.8(lagging) The regulating rate of ...
...phase generator 250kva powered by Cummins NT855GA for sale Technical data Genset Model SC250E6 Prime Power 200KW/250KVA Rated Voltage 400/230V Frequency 60Hz Power Factor 0.8(lagging) The regulating rate of ...
.../2HP Single Phase For Pressure Washer Hollow Shaft Motor Single-phase hollow shaft motors are mainly used in household cleaning equipment. Shaft Size:24mm hollow Horsepower:1.5kw/2HP Rpm:1400 Voltage:220V Ph...
..., China Brand Name: INTWATT Model Number: EX3320~EX3380K Phase: Three Phase Weight: 248kgs-380kgs Output Voltage: 380V/220VAC Type: High Frequency Online UPS Protection: Short Circuit Application: Data-cente...
..., China Brand Name: INTWATT Model Number: EX3320~EX3380K Phase: Three Phase Weight: 248kgs-380kgs Output Voltage: 380V/220VAC Type: High Frequency Online UPS Protection: Short Circuit Application: Data-cente...
... /160KVA Standby Power(50HZ) 140KW /176KVA Frequency/Speed 50Hz/1500rpm Standard Voltage 230V/400V Voltage Available 220V/380V,240V/415V Phases Three phases, four wires Engine Specification General Performan...
...Voltage AC Three Phase 150KW188KVA Portable Diesel Generator Set Backup Power TECHNICAL DATA - 150KW/188KVA Genset Power Capacity (kw/kva) Prime 150/188 Standby 165/206 Rated Voltage Volt 400/230 Rated Curre...
... COSΦ=0.8(lagging) Protection Low oil-pressure, High water temperature, Over-speed, Over-current., High Coolant temperature, Over load, Over/under/unbalance voltage. Fuel Consumption 88.8L/h (100% load)@prim...