| Sign In | Join Free | My burrillandco.com |
|
4-20mA to 0-10V isolation amplifier Applications: ◆ DC current/voltage signal isolation, conversion and amplification ◆ Analog signal ground interference suppression ◆ 4~20mA/0~20mA/0~10mA/0~5V/0~10V/1~5V etc. ...
...20mA passive loop-powered isolated module General description: JSD MI 4~20mA-F series isolation amplifier IC is a two-wire loop-powered galvanic isolation module, It adopts electromagnetic isolation technolo...
...20mA to frequency pulse transmitter I/F converter Selection Example: Example 1:Signal Input: 4-20mA;Signal Output :0-10KHz (5V voltage pulse);Power Supply:9-36VDC; Model:JSD TAF-1001S-DW2 Example 2:Signal In...
...20mA/0-10V to 0~10KHz/0-20KHZ I/F V/F converter selection example: Example 1:Signal Input: 0-5V;Signal Output :0-10KHz (5V voltage pulse);Power Supply:9-36VDC; Model:JSD TAF-1001S-1W2 Example 2:Signal Input:...
...20mA/0-10V signal isolation transmitter(F/V,F/I converter) Selection Example: Example 1:Signal Input: 0-10KHz (5V voltage pulse );Signal Output : 0-10VDC;Power Supply:12VDC;Model:JSD TFA-1001-233 Example 2:S...
...20mA isolation transmitter (F/V,F/I converter) Selection Example: Example 1:Signal Input: 0-10KHz (5V voltage pulse );Signal Output : 0-10VDC;Power Supply:12VDC; Model:JSD TFA-1001-233 Example 2:Signal Input...
...: 0-5KHz ( Open collector );Signal Output : 4-20mA;Power Supply:24VDC;Model:JSD TFA-1001-511 Example 3:Signal Input: 0-15KHz (5V voltage pulse );Signal Output : 0-20mA;Power Supply:9-36VDC;Model:JSD TFA-1001...
...20mA D/A converter selection example: Sample 1: Model:JSD DA-A02-485-IO4 RS-485 Interface,4-20mA signal output Sample 2: Model:JSD DA-A02-232-VO1 RS-232 Interface,0-5V signal output Sample 3: Model:JSD DA-A0...
4-20mA high accuracy 3-in-3-out Isolation Transmitter/active 4-20mA isolation transmitter Features 1.thin volume , low-cost international standards DIN35mm rail mounting 2.Multi-port isolation ( input and outpu...
...20mA/0-10VDC analog signal to frequency pulse signal high accuracy isolation transmitter (V/F I/F converter) Selection Example: Example 1:Signal Input: 0-5V;Signal Output :0-10KHz (5V voltage pulse);Power Su...
...20mA, DC:10mA Voltage Withstand Test Instrument Operation condition: Environment Temperature: 0~40°C Relative Humidity: ≤75% Atmospheric Pressure: 101.25KPa Technical Index: Item RK2671AM Output Voltage Rang...
...20mA high accuracy isolation transmitter( 1-in-1-out/2-in-2-out/3-in-3-out/4-in-4-out) passive 4-20mA isolation transmitter have PCB board soldering and standard DIN 35mm rail slot fixed installation of two ...
...data acquisition,CE approved 4-20mA to RS485 Features: >> Eight analog signal acquisition, isolated converter RS-485/232 output >> 24-bit AD converter, accuracy>0.05% >> 4-20mA/0-20mA current signal or 0-5V/...
4-20mA to 4-20mA passive signal converters DIN11 IAP 4-20mA is a signal isolated converter, contains current signal modulate-demodulate and isolated coupled circuit. To meet the requirements of long distance tr...
... U2: 0-10V A2: 0-10mA 232: RS-232 output interface U3: 0-75mV A3: 0-20mA U4: 0-2.5V A4: 4-20mA U5: 0-±5V A5: 0-±1mA U6: 0-±10V A6: 0-±10mA U7: 0-±100mV A7: 0-±20mA U8: user-defined A8: user-defined Selection...
...20ma output water gas liquid steam vortex flow meter: LUCB insert type 4-20ma output water gas liquid steam vortex flow meter, which can be widely applicable to all kinds of industry of large diameter gas, l...
...20mA nitrogen gas mass flow meter: 4-20mA nitrogen gas mass flow meter are specially designed for small pipe flow monitoring and control. The series can measure gas flow in a pipe diameter as small as 3 mm,b...
...data acquisition,CE approved 4-20mA to RS485 Features: >> Eight analog signal acquisition, isolated converter RS-485/232 output >> 24-bit AD converter, accuracy>0.05% >> 4-20mA/0-20mA current signal or 0-5V/...