| Sign In | Join Free | My burrillandco.com |
|
...load break switch with fuse FN5 type indoor 3 phase 7.2kv 10kv 11kv 12kv gang operated load break switch with fuse .It is designed and developed by our own company by bringing in international advanced techn...
... ±0.02%F.S Creep(30minutes) ±0.02%F.S Recommended Excitation Voltage 5V~18V(AC or DC) Maximum Excitation Voltage 24V(AC or DC) Zero Balance ±1%F.S Input Impedance 775±10Ω Output Impedance 700±5Ω Insulation I...
...load cell 1000kg Customized Pressure Sensor Force Transducer Button load cell Specifications Technical Parameter Rated Load T 0.05/0.1/0.2/0.5/1/2/5/10/20 Sensitivity mV/V 2.0000±0.002 Total Error %F.S ±0.01...
...Load Cell Pancake Weighing Sensor Load Cell Specifications Technical Parameter Rated Load T 0.5/1/2/3/5/10/20/30/40/50/60 Sensitivity mV/V 2.0000±0.002 Total Error %F.S ±0.02 Creep(30minutes) %F.S ±0.02 Reco...
...) ±0.02%F.S Recommended Excitation Voltage 5V~12V(AC or DC) Maximum Excitation Voltage 15V(AC or DC) Zero Balance ±1%F.S Input Impedance 775±10Ω Output Impedance 700±5Ω Insulation Impedance ≥5000MΩ Safe Over...
...Load Cell Pan cake 20 ton Through Hole Load Cell for Drag Specifications Technical Parameter Rated Load 20t Sensitivity 2.0000mV/V Total Error ±0.1%F.S Creep(30minutes) ±0.02%F.S Recommended Excitation Volta...
...load cell Compression load cell 1000kg For Orbit Weighted Specifications Technical Parameter Rated Load T 0.5/1/2/3/5/10/30/40/50/60 Sensitivity mV/V 2.0000±0.002 Total Error %F.S ±0.02 Creep(30minutes) %F.S...
...load cell Sensor Pull Pressure Weighing Module Automatic Force load cell Specifications Technical Parameter Rated Load KG 50~200 Sensitivity mV/V 2.0000±0.002 Total Error %F.S ±0.01 Creep(30minutes) %F.S ±0....
...Load Cell Low Cost Weight Sensor Single Point Load Cell Specifications Technical Parameter Rated Load 50kg-1000kg Sensitivity 2.0000±0.001mV/V Total Error ±0.02%F.S Creep(30minutes) ±0.02%F.S Recommended Exc...
...Load Cell 300kg 1000kg Platform Scales Single Point Load Cell Specifications Technical Parameter Rated Load 100kg-1000kg Sensitivity 2.0000±0.001mV/V Total Error ±0.02%F.S Creep(30minutes) ±0.02%F.S Recommen...
...load cell QS Double Ended Shear Beam Load Cell Specifications Technical Parameter Rated Load T 10/15/20/25/30/40 Resd Output Div 2.0000±0.002 Total Error %F.S 0.02 Creep (30 minutes) %F.S 0.02 Recommended Ex...
...) ±0.02%F.S Recommended Excitation Voltage 5V~18V(AC or DC) Maximum Excitation Voltage 24V(AC or DC) Zero Balance ±1%F.S Input Impedance 775±10Ω Output Impedance 700±5Ω Insulation Impedance ≥5000MΩ Safe Over...
...Load Cell weighbridge load cell force sensor Tank Scales silo weighing system Specifications Rated Load 5~100klibt Rated Ouput 2.0000+0.002mVi Total Error ±0.02%F.S Creep[30minutes) ±0.02%FS Recommended Exci...
...) ±0.02%F.S Recommended Excitation Voltage 5V~18V(AC or DC) Maximum Excitation Voltage 24V(AC or DC) Zero Balance ±1%F.S Input Impedance 380±5Ω Output Impedance 350±2Ω Insulation Impedance ≥5000MΩ Safe Overl...
...isolating the source from the consumer. Whether they are manual, motorised or with a trip function, these devices ensure the on-load making, breaking and safety disconnection of low-voltage electrical circui...
... listed in the BOM of an electronic device. The BOM is a document that lists all the components required to manufacture the device, including the type and quantity of each component. ICs are an essential com...
Custome Design Professional 480v 1500kw AC Load Bank Capacity Tester Product Description Automatic AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch pow...
1000KW AC Load Bank For Backup Power Supply Generator UPS Transformer Product Description 1. Automatic AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch...
...Ac Adapter/ UL,CUL 1310 Aapproval Specification Datasheet Table GUP28 series PRIMARY EXCITING CURRENT I/P:120VAC 60Hz / 5mA MAX Primary full load current 120VAC 60Hz / 35mA MAX Secondary Voltage No Load 10....
Custome Design Professional 480v 1500kw AC Load Bank Capacity Tester Product Description Automatic AC load bank main used to test the capability and aging degree for high-power ups on-line, inverter, switch pow...