| Sign In | Join Free | My burrillandco.com |
|
..., is used indoor for measuring current, electric energy and protective relaying in the electric system with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV. The product has the feature of h...
...designed to "step up" or "step down" voltages and works on the magnetic induction principle. A transformer has no moving parts and is a completely static solid state device, which insures, under normal opera...
MV Voltage Transformer 24Kv Outdoor Three-Phase Epoxy Resin Type Combined Transformer 1. Introduction: The transformer is made up of three single phase combined transformers. It can be used outdoor, Its highest...
...Voltage Transformer The transformer is made up of three single phase combined transformers. It can be used outdoor, Its highest voltage for equipment can be 17.5kV. Technical Data 1.Installation site Outdoor...
...Transformer for Power Supply,ac transformer Electrical specification: Pri voltage: 230V±10% Output: 12V,2.5A Operating frequency: 50/60Hz No-load loss: 1.5W Max Insulation class: B Power: 30VA Voltage regula...
... difference is that, as their name implies, they operate at much higher frequencies — while most line voltage transformers operate at 50 or 60 Hz, high-frequency transformers use frequencies from 20 KHz to o...
.... The products use resistive partial-pressure method to test voltage, mainly be used in the ≤ 35kV switchgear, compatible with electric instrument, digital measure and protective equipment, able to conduct m...
Instrument transformer for Air insulator switchgear JDZX10-24 Voltage transformer supply Indoor,inductive voltage transformer,epoxy resin casting insulation and fully enclosed support construction,encloses prim...
...transformer, power transformer,EI41, high quality,Power type epoxy low frequency transformer 1. Electrical characteristics: 1) input characteristics: Input voltage N1 (1-5):380V/50Hz (input AC 380V voltage a...
...fully enclosed construction, is used for measuring voltage, electric energy and protective relaying in the electric system with the frequency 50Hz or 60Hz and highest voltage for equipement 12kV. The product...
...Voltage Transformer Description JDZ10-11R voltage transformer, epoxy resin casting and full-enclosed construction, is widely used for measuring current, electric energy and protective relaying in the single-...
...protective relaying in the single-phase or three phase power system with the frequency 50Hz or 60Hz and highest voltage for equipment 12kV. Technical Data: 1,Installation site: Outdoor 2,Rated frequency: 50/...
... outdoor, Its highest voltage for equipment can be 17.5kV. 2. Specification: Rated primary Voltage(kV) Rated secondary Voltage(kV) Accuracy classes Rated output(VA) Rated current ratio (A) Accuracy class Rat...
...Voltage Transformer-JDZXW6-36 Description: Epoxy resin casting and full-closed construction, single-pole for phase to ground connection, It is widely used for measuring voltage, electric energy and protectiv...
... is that, as their name implies, they operate at much higher frequencies — while most line voltage transformers operate at 50 or 60 Hz, high-frequency transformers use frequencies from 20 KHz to over 1MHz.Op...
.... Commercially available relays and meters used for protection and metering, are designed for low voltage. This is a simplest form of potential transformer definition. A voltage transformer theory or potenti...
...5KVA 220V Single Phase Constant Voltage Transformer CVT Quick Detail: Constant Voltage Transformer TJA-5KVA Frequency: 50/60HZ Weight: 136kg Dimension(W×H×D)mm: 320×710×520 Description: Constant Voltage Tran...
...5KVA 220V Single Phase Constant Voltage Transformer CVT Quick Detail: Constant Voltage Transformer TJA-5KVA Frequency: 50/60HZ Weight: 136kg Dimension(W×H×D)mm: 320×710×520 Description: Constant Voltage Tran...
...Voltage Transformer 12kV VT IEEE BUSHING TYPE Resistance Contamination 1.Product Introduction: Voltage transformer with fully enclosed cast insulation structure, the primary and secondary windings and toroid...